Indexed In : Science Citation Index Expanded(SCIE), MEDLINE,
Pubmed/Pubmed Central, Elsevier Bibliographic, Google Scholar,
Databases(Scopus & Embase), KCI, KoreaMed, DOAJ
Gut and Liver is an international journal of gastroenterology, focusing on the gastrointestinal tract, liver, biliary tree, pancreas, motility, and neurogastroenterology. Gut atnd Liver delivers up-to-date, authoritative papers on both clinical and research-based topics in gastroenterology. The Journal publishes original articles, case reports, brief communications, letters to the editor and invited review articles in the field of gastroenterology. The Journal is operated by internationally renowned editorial boards and designed to provide a global opportunity to promote academic developments in the field of gastroenterology and hepatology. +MORE
Yong Chan Lee |
Professor of Medicine Director, Gastrointestinal Research Laboratory Veterans Affairs Medical Center, Univ. California San Francisco San Francisco, USA |
Jong Pil Im | Seoul National University College of Medicine, Seoul, Korea |
Robert S. Bresalier | University of Texas M. D. Anderson Cancer Center, Houston, USA |
Steven H. Itzkowitz | Mount Sinai Medical Center, NY, USA |
All papers submitted to Gut and Liver are reviewed by the editorial team before being sent out for an external peer review to rule out papers that have low priority, insufficient originality, scientific flaws, or the absence of a message of importance to the readers of the Journal. A decision about these papers will usually be made within two or three weeks.
The remaining articles are usually sent to two reviewers. It would be very helpful if you could suggest a selection of reviewers and include their contact details. We may not always use the reviewers you recommend, but suggesting reviewers will make our reviewer database much richer; in the end, everyone will benefit. We reserve the right to return manuscripts in which no reviewers are suggested.
The final responsibility for the decision to accept or reject lies with the editors. In many cases, papers may be rejected despite favorable reviews because of editorial policy or a lack of space. The editor retains the right to determine publication priorities, the style of the paper, and to request, if necessary, that the material submitted be shortened for publication.
Jun-Ho Choi, Dong-Wan Seo*, Do Hyun Park, Sung Koo Lee, and Myung-Hwan Kim
Division of Gastroenterology, Department of Internal Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Correspondence to: Dong-Wan Seo. Division of Gastroenterology, Department of Internal Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 138-736, Korea. Tel: +82-2-3010-3192, Fax: +82-2-476-0824, dwseoamc@amc.seoul.kr
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Gut Liver 2014;8(1):88-93. https://doi.org/10.5009/gnl.2014.8.1.88
Published online August 14, 2013, Published date January 29, 2014
Copyright © Gut and Liver.
Stereotactic body radiation therapy (SBRT) for gastrointestinal malignancies requires the placement of fiducials to guide treatment delivery. This study aimed to determine the safety and technical feasibility of endoscopic ultrasonography (EUS)-guided fiducial placement for SBRT.
From November 2010 to August 2012, 32 consecutive patients who were scheduled to receive SBRT for pancreatic and hepatic malignancies were referred for EUS-guided fiducial placement. Primary outcome measurements included technical success, the fiducial migration rate, and procedural complications.
All 32 patients had successful fiducial placement under EUS guidance. The mean number of fiducials placed per patient was 2.94±0.24 (range, 2 to 3 seeds). Spontaneous fiducial migration was noted in one patient (3.1%). Of the 32 patients with fiducials placed, 29 patients (90.6%) successfully underwent SBRT. One patient (3.1%) developed mild pancreatitis, requiring a 2-day prolonged hospitalization after fiducial placement. Five patients (15.6%) underwent same-session, EUS-guided fine needle aspiration for histologic confirmation at the time of fiducial placement, without any procedure-related complication.
EUS-guided fiducial placement is a safe and technically feasible technique for preparing patients with both pancreatic and hepatic malignancies for SBRT. The fiducial markers facilitate safe and accurate targeting of the tumor during SBRT.
Keywords: Fiducial markers, Endosonography, Radiosurgery, Pancreatic neoplasms, Liver neoplasms
Stereotactic body radiation therapy (SBRT) allows for the delivery of high radiation doses while minimizing toxicity on adjacent organs.1,2 This technique demands high targeting accuracy, taking into account respiratory and other involuntary motion of the target lesion during radiation therapy.2 SBRT needs fiducial markers for target localization and tracking.2 Fiducial markers serve as reference points for computed tomography (CT) planning and allow for simultaneous correction of target motion. Traditionally, fiducial markers have been placed either intraoperatively or percutaneously under ultrasound (US) or CT guidance.3 Percutaneous approaches for fiducial placement can be taken for superficial lesions, but may not be feasible for deeper lesions. Given the capability of endoscopic ultrasonography (EUS) to allow for close proximity to deeper abdominal structures that are not easily accessible via percutaneous approaches, EUS-guided fiducial placement is a more effective method of localizing these tumors.
EUS-guided fiducial placement has recently been reported as a technically feasible technique for mediastinal and other abdominal malignancies,4-9 including the pancreas, oesophagus, stomach, or porta hepatis. The aim of our study was to demonstrate the safety and technical feasibility of EUS-guided fiducial placement for pancreatic and hepatic malignancy.
From November 2010 to August 2012, 32 consecutive patients (21 male, 11 female) who were scheduled to receive SBRT for malignancy were referred for EUS-guided fiducial placement. Patients with coagulopathy (international normalized ratio >1.5, platelets <50,000) were transfused with the appropriate blood products for correction of coagulopathy. An allergy to gold or concomitant inflammatory disease was considered a contraindication for gold marker implantation. All procedures were performed in the endoscopy unit at the Asan Medical Center by single experienced endosonographers (D.W.S.), who perform more than 350 EUS procedures annually for pancreaticobiliary diseases. This study was approved by the Institutional Review Board at Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea. Informed patient consent was obtained before each procedure.
Patients were sedated with intravenous injections of 3 to 5 mg midazolam. Periprocedural intravenous antibiotics (cefotaxime 2 g or ciprofloxacin 400 mg) were administered prophylactically in all patients for 1 day. Anticoagulation and antiplatelet medications were discontinued according to the guidelines for endoscopic procedures.10
A linear array echoendoscope (GF-UC240P-AL5; Olympus Co., Tokyo, Japan or EG-3870 UTK; Pentax, Hamburg, Germany) was used to perform the EUS. A standard 19-gauge needle (Echotip; Cook Medical, Winston-Salem, NC, USA) was used to deploy a gold fiducial marker measuring 0.8×3 mm (CIVCO Medical Solutions, Orange City, IA, USA). The system used by our hospital for SBRT was RapidArc (Varian Medical Systems, Palo Alto, CA, USA).
Using sterile forceps, each cylindrical gold seed was back-loaded into the tip of a 19 G Echotip needle with the stylet withdrawn 7 to 8 mm. The needle was then pressed into bone wax (Ethicon, Somerville, NJ, USA) to seal it into place. Once a safe needle direction had been identified under EUS guidance, the needle with the backloaded fiducial was passed through the working channel of the scope and the fiducial was deployed into or near the tumor by advancing the stylet (Fig. 1). The needle was then withdrawn from the echoendoscope and reloaded with a new fiducial marker, and the procedure was repeated with the placement of two or three fiducials about 1.5 cm apart. Fiducial positioning was confirmed with a real time EUS image, as well as an abdominal roentgenogram after the procedure (Fig. 2). A marker was usually seen as a hyperechoic structure with a ringdown artifact behind it. After implanting all markers, we checked the position of each marker in the transverse and sagittal planes to determine the distance between fiducial markers, which is essential for treatment planning. All patients were admitted to the hospital for one day to monitor any complications. An outpatient course of oral antibiotics was not given upon patient discharge, but patients were instructed to report any delayed symptoms such as fever, chills, abdominal pain, or any other unexpected symptoms for a period of 1 month.
Technical success was defined as puncturing the target lesion accurately and the ability to implant more than two fiducials in the appropriate location for SBRT. Fiducial migration was defined as seed dislodgement outside the volume of the original injection site and unusable for guiding SBRT as determined by planning CT.
The SBRT technique used in our institute is described as follows. First, patients were immobilized in a stereotactic body frame (Elekta Oncology, Norcross, GA, USA). CT simulations were performed 10 to 14 days after fiducial marker placement and reviewed by a radiation oncologist to verify the feasibility of using SBRT enabled by the fiducial markers (Fig. 3). For lesions that moved more than 5-mm on fluoroscopic imaging, 4-dimensional CT scanning and gated delivery was performed using the Real-Time Position Management System (Varian Medical Systems). Treatment planning was formulated with the Eclipse Planning System (Varian Medical Systems). Fractional doses of 6 to 8 Gy were delivered to target volume for consecutive 4 days. Fractionated schedules were employed as follows: 26 to 28 Gy in four fractions for pancreatic cancer (28 patients), 30 Gy in four fractions for celiac lymph node metastasis (one patient). We checked daily setup accuracy with cone-beam CT and/or fluoroscopy.
Thirty-two patients (21 male, 11 female) underwent EUS-guided fiducial placement. The mean age of patients was 66 years (range, 46 to 90 years). The location and pathologic diagnosis of tumors were as follows: celiac lymph node (lymph node metastasis from hepatocellular carcinoma), caudate lobe (hepatocellular carcinoma), retrocrural area (metastatic carcinoma from hepatocellular carcinoma), and pancreas. Of the pancreatic cancers, 10 were located in the head, two in the uncinate process, and 17 in the body/tail. The mean size of the tumors was 3.2±1.1 cm (range, 1.9 to 7.0 cm). Patient and procedural characteristics are described in Table 1.
The fiducial placement under EUS guidance was technically successful in 32 out of 32 patients (100%). Only one patient (3.1%) developed a mild pancreatitis requiring a 2-day prolonged hospitalization after fiducial placement. The patient presented worsening abdominal pain 18 hours after the placement of three fiducials in the pancreatic body mass. The patient's serum lipase was elevated to 420 IU/L. An abdominal CT scan showed mild swelling of the pancreas around the implanted fiducials. The patient was treated conservatively and recovered before the scheduled SBRT.
Five patients (15.6%) underwent same session EUS-guided fine needle aspiration (FNA) for tissue diagnosis at the time of fiducial placement without any procedure related complications.
Among the 32 patients who had fiducial placement under EUS guidance, 29 patients (90.6%) successfully underwent SBRT. Three patients did not undergo planned SBRT due to disease progression (n=2), transfer to another institution (n=1).
Generally, two or three fiducials were implanted into and around the tumor. A total of 94 fiducials were implanted in 32 patients, 34 using a transgastric approach and 60 using a transduodenal approach. The mean number of fiducials per patients was 2.94±0.24 (range, 2 to 3 seeds). Two patients with pancreatic head cancer were implanted with two fiducials because they already had a biliary metallic stent that can be used as reference marker, thereby allowing three-dimensional configuration with only two implanted fiducials.
Spontaneous fiducial migration was noted in one patients (3.1%). Three gold fiducials were inserted under EUS, and two fiducials were seen on subsequent planning CT; however, the ability to use the remaining fiducial markers for SBRT was adequate without requiring a repeat EUS procedure. Overall, fiducial migration occurred in one of 94 seeds placed (1.1%). There was no further reported fiducial migration throughout the course of radiation therapy. This was verified by comparing the cone beam CT images acquired before each day of therapy with the initial planning CT images.
In current study, we demonstrated the technical feasibility and safety of EUS-guided fiducial placement in either hepatic or pancreatic malignancy using a 19-gauge needle. The technical success rate of 100% demonstrates the feasibility of this technique for these cancers. Of the 32 patients who had EUS-guided fiducials implanted, 29 patients (90.6%) successfully underwent SBRT. We encountered no severe resistance while deploying the fiducial seeds. As the study was retrospective, it should be appreciated that preferential candidates for EUS-guided fiducial placement may have been included, thereby resulting in a high success rate. In addition, a previous study noted that failure to place a fiducial in the target lesion was attributable to an anatomical alteration or a limitation of the use of 5-mm-long fiducials.5,7 However, the present study included only one patient with surgically altered anatomy and used gold fiducials measuring 3 mm in length, potentially influencing our high success rate. In our experience, the fluoroscopic assistance was not necessary during the procedure of fiducial placement. We could identify the fiducials placed under EUS alone, thereby verifying the proper placement immediately.
There have been several published studies on the feasibility of EUS-guided fiducial placement for various mediastinal and abdominal malignancies.4-9 Four studies investigated the feasibility of EUS-guided fiducial placement using a 19-gauge FNA needle to deploy cylindrical gold seeds measuring 2.5 to 5 mm in length with 0.8 mm diameter, reporting a high success rate.5-7,9 Two studies demonstrated the feasibility of EUS-guided fiducial placement using a 22-gauge FNA needle to deploy gold coil fiducials measuring 10 mm in length with 0.35 mm diameter, offering potential advantages over the use of a 19-gauge needle.4,8 EUS-guided fine-needle injection using a 19-gauge needle performed in pancreatic lesions of the head and uncinate process is often challenging because of the acute angulation. Larghi et al.11 stated that the degree of deflection of the echoendoscope tip is the major factor responsible for bringing the target lesion into an appropriate position, which precludes extension of the needle from the accessory channel. For such hard to reach tumors, it is preferable to place the fiducial markers around the periphery of the tumor, rather than directly in the tumor, provided there is not a substantial difference between respiratory movement of the fiducials and the actual target tumor. Recently, one retrospective study comparing traditional fiducials (5-mm length, 0.8-mm diameter) and Visicoil fiducial (10-mm length, 0.35-mm diameter) demonstrated that there was no significant difference between the two fiducial types in terms of technical success, complications, and migration.12 However, it remains unclear whether the use of a 22-gauge needle instead of a 19-gauge needle affects the technical success and complication rates of the procedure until prospective randomized study is completed. It is also unclear whether the thinner caliber 0.35 mm fiducials affect the accurate tracking of the fiducials by the SBRT system compared to the standard 0.8 mm fiducials. Further prospective randomized studies are warranted to evaluate the technical success and complication rates of the EUS-guided fiducial placement using 19-gauge and 22-gauge needles. In previous studies, the target lesions for fiducial placement have been located in the mediastinum, abdomen and GI system including the pancreas, stomach, liver, and porta hepatis. The success rates for EUS-guided fiducial placement were reported to range from 85% to 100%.4-8 Reported procedure related complications were cholangitis (n=2), mild pancreatitis (n=1), fever (n=1), or minor bleeding (n=1).4-8,13 Based on previous literature and the current study, the overall technical success and complication rates of EUS-guided fiducial placement in GI malignancy were 96% and 2%, respectively (Table 2).
The fiducial placement may introduce air bubbles into the target lesion, which obscures EUS visualization and leads to difficulty in confirming fiducial placement. To prevent the introduction of air into the lesion, the stylet was withdrawn 7 to 8 mm while backloading the fiducial into the needle and was sealed in place with bone wax. No air bubbles were noted after fiducial deployment using this technique. Although the optimal seed number and location required for SBRT has not been established, we tried implanting at least two fiducials within or adjacent to the mass to account for the possibility of potential migration requiring repeat EUS procedures. In the present study, overall fiducial migration occurred in one of 94 seeds placed (1.0%).
In five cases, the lesion was presumed to be malignant on the basis of the imaging studies and the patient's history. Thus, five patients underwent same session EUS-FNA followed by fiducial placement without subsequent complication. Performing both procedures in the same session has several advantages such as expediting treatment and reducing the length of hospital stay. If EUS-FNA is planned for tissue diagnosis, our results indicate that it can be performed at the time of EUS-guided fiducial placement. Nonetheless, there remains a theoretical concern that performing both procedures simultaneously may cause trauma, resulting in procedure-related complications. Mild pancreatitis has been previously reported as a potential complication of EUS-guided fiducial placement with simultaneous EUS-guided celiac plexus neurolysis.5 For this issue, additional study may be considered.
Tumor seeding due to FNA is extremely rare. In percutaneous FNA under either US or CT guidance, the incidence ranges from 0.005% to 0.009%; however, in the case of EUS-FNA, it is considered to be even lower due to the shorter puncture path. Thus far, only three cases have been reported.14-16 Whether placement of the fiducial implantation within the tumor rather than adjacent to the tumor affects the seeding remains to be evaluated.
Following a previous report of procedure-related cholangitis,7,13 it is recommended that all patients receive prophylactic antibiotics, although strong evidence for this precaution, e.g., a prospective study, is lacking.17 In previous feasibility studies, all patients received an arbitrary 5-day course of antibiotics for infection prophylaxis.5,6,8 In the present study, all patients received a 1-day course of preprocedural and postprocedural intravenous antibiotics. There is ambiguity regarding the role of routine antibiotic prophylaxis prior to EUS-guided fiducial placement. More data are needed to evaluate the role of prophylactic antibiotics and the administering schedule of antibiotics if necessary.
Our study has several limitations. This was a retrospective study at a single tertiary medical center where all EUS procedures were undergone by a single experienced endosonographer. This study was not designed to evaluate a survival benefit or quality of life associated with EUS-guided fiducial placement as a method to support SBRT.
In conclusion, EUS-guided fiducial placement for SBRT in pancreatic and hepatic malignancy appears to be a safe and feasible technique when performed by an experienced endosonographer. This novel application of interventional EUS further expands the role of EUS in the multidisciplinary team approach to patients with pancreatic and hepatic malignancy. The fiducial markers would facilitate safe and accurate targeting of the tumor during SBRT.
M, male; F, female; LN, lymph node.
P, prospective; R, retrospective; C, case series.
Gut Liver 2014; 8(1): 88-93
Published online January 29, 2014 https://doi.org/10.5009/gnl.2014.8.1.88
Copyright © Gut and Liver.
Jun-Ho Choi, Dong-Wan Seo*, Do Hyun Park, Sung Koo Lee, and Myung-Hwan Kim
Division of Gastroenterology, Department of Internal Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Correspondence to: Dong-Wan Seo. Division of Gastroenterology, Department of Internal Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 138-736, Korea. Tel: +82-2-3010-3192, Fax: +82-2-476-0824, dwseoamc@amc.seoul.kr
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Stereotactic body radiation therapy (SBRT) for gastrointestinal malignancies requires the placement of fiducials to guide treatment delivery. This study aimed to determine the safety and technical feasibility of endoscopic ultrasonography (EUS)-guided fiducial placement for SBRT.
From November 2010 to August 2012, 32 consecutive patients who were scheduled to receive SBRT for pancreatic and hepatic malignancies were referred for EUS-guided fiducial placement. Primary outcome measurements included technical success, the fiducial migration rate, and procedural complications.
All 32 patients had successful fiducial placement under EUS guidance. The mean number of fiducials placed per patient was 2.94±0.24 (range, 2 to 3 seeds). Spontaneous fiducial migration was noted in one patient (3.1%). Of the 32 patients with fiducials placed, 29 patients (90.6%) successfully underwent SBRT. One patient (3.1%) developed mild pancreatitis, requiring a 2-day prolonged hospitalization after fiducial placement. Five patients (15.6%) underwent same-session, EUS-guided fine needle aspiration for histologic confirmation at the time of fiducial placement, without any procedure-related complication.
EUS-guided fiducial placement is a safe and technically feasible technique for preparing patients with both pancreatic and hepatic malignancies for SBRT. The fiducial markers facilitate safe and accurate targeting of the tumor during SBRT.
Keywords: Fiducial markers, Endosonography, Radiosurgery, Pancreatic neoplasms, Liver neoplasms
Stereotactic body radiation therapy (SBRT) allows for the delivery of high radiation doses while minimizing toxicity on adjacent organs.1,2 This technique demands high targeting accuracy, taking into account respiratory and other involuntary motion of the target lesion during radiation therapy.2 SBRT needs fiducial markers for target localization and tracking.2 Fiducial markers serve as reference points for computed tomography (CT) planning and allow for simultaneous correction of target motion. Traditionally, fiducial markers have been placed either intraoperatively or percutaneously under ultrasound (US) or CT guidance.3 Percutaneous approaches for fiducial placement can be taken for superficial lesions, but may not be feasible for deeper lesions. Given the capability of endoscopic ultrasonography (EUS) to allow for close proximity to deeper abdominal structures that are not easily accessible via percutaneous approaches, EUS-guided fiducial placement is a more effective method of localizing these tumors.
EUS-guided fiducial placement has recently been reported as a technically feasible technique for mediastinal and other abdominal malignancies,4-9 including the pancreas, oesophagus, stomach, or porta hepatis. The aim of our study was to demonstrate the safety and technical feasibility of EUS-guided fiducial placement for pancreatic and hepatic malignancy.
From November 2010 to August 2012, 32 consecutive patients (21 male, 11 female) who were scheduled to receive SBRT for malignancy were referred for EUS-guided fiducial placement. Patients with coagulopathy (international normalized ratio >1.5, platelets <50,000) were transfused with the appropriate blood products for correction of coagulopathy. An allergy to gold or concomitant inflammatory disease was considered a contraindication for gold marker implantation. All procedures were performed in the endoscopy unit at the Asan Medical Center by single experienced endosonographers (D.W.S.), who perform more than 350 EUS procedures annually for pancreaticobiliary diseases. This study was approved by the Institutional Review Board at Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea. Informed patient consent was obtained before each procedure.
Patients were sedated with intravenous injections of 3 to 5 mg midazolam. Periprocedural intravenous antibiotics (cefotaxime 2 g or ciprofloxacin 400 mg) were administered prophylactically in all patients for 1 day. Anticoagulation and antiplatelet medications were discontinued according to the guidelines for endoscopic procedures.10
A linear array echoendoscope (GF-UC240P-AL5; Olympus Co., Tokyo, Japan or EG-3870 UTK; Pentax, Hamburg, Germany) was used to perform the EUS. A standard 19-gauge needle (Echotip; Cook Medical, Winston-Salem, NC, USA) was used to deploy a gold fiducial marker measuring 0.8×3 mm (CIVCO Medical Solutions, Orange City, IA, USA). The system used by our hospital for SBRT was RapidArc (Varian Medical Systems, Palo Alto, CA, USA).
Using sterile forceps, each cylindrical gold seed was back-loaded into the tip of a 19 G Echotip needle with the stylet withdrawn 7 to 8 mm. The needle was then pressed into bone wax (Ethicon, Somerville, NJ, USA) to seal it into place. Once a safe needle direction had been identified under EUS guidance, the needle with the backloaded fiducial was passed through the working channel of the scope and the fiducial was deployed into or near the tumor by advancing the stylet (Fig. 1). The needle was then withdrawn from the echoendoscope and reloaded with a new fiducial marker, and the procedure was repeated with the placement of two or three fiducials about 1.5 cm apart. Fiducial positioning was confirmed with a real time EUS image, as well as an abdominal roentgenogram after the procedure (Fig. 2). A marker was usually seen as a hyperechoic structure with a ringdown artifact behind it. After implanting all markers, we checked the position of each marker in the transverse and sagittal planes to determine the distance between fiducial markers, which is essential for treatment planning. All patients were admitted to the hospital for one day to monitor any complications. An outpatient course of oral antibiotics was not given upon patient discharge, but patients were instructed to report any delayed symptoms such as fever, chills, abdominal pain, or any other unexpected symptoms for a period of 1 month.
Technical success was defined as puncturing the target lesion accurately and the ability to implant more than two fiducials in the appropriate location for SBRT. Fiducial migration was defined as seed dislodgement outside the volume of the original injection site and unusable for guiding SBRT as determined by planning CT.
The SBRT technique used in our institute is described as follows. First, patients were immobilized in a stereotactic body frame (Elekta Oncology, Norcross, GA, USA). CT simulations were performed 10 to 14 days after fiducial marker placement and reviewed by a radiation oncologist to verify the feasibility of using SBRT enabled by the fiducial markers (Fig. 3). For lesions that moved more than 5-mm on fluoroscopic imaging, 4-dimensional CT scanning and gated delivery was performed using the Real-Time Position Management System (Varian Medical Systems). Treatment planning was formulated with the Eclipse Planning System (Varian Medical Systems). Fractional doses of 6 to 8 Gy were delivered to target volume for consecutive 4 days. Fractionated schedules were employed as follows: 26 to 28 Gy in four fractions for pancreatic cancer (28 patients), 30 Gy in four fractions for celiac lymph node metastasis (one patient). We checked daily setup accuracy with cone-beam CT and/or fluoroscopy.
Thirty-two patients (21 male, 11 female) underwent EUS-guided fiducial placement. The mean age of patients was 66 years (range, 46 to 90 years). The location and pathologic diagnosis of tumors were as follows: celiac lymph node (lymph node metastasis from hepatocellular carcinoma), caudate lobe (hepatocellular carcinoma), retrocrural area (metastatic carcinoma from hepatocellular carcinoma), and pancreas. Of the pancreatic cancers, 10 were located in the head, two in the uncinate process, and 17 in the body/tail. The mean size of the tumors was 3.2±1.1 cm (range, 1.9 to 7.0 cm). Patient and procedural characteristics are described in Table 1.
The fiducial placement under EUS guidance was technically successful in 32 out of 32 patients (100%). Only one patient (3.1%) developed a mild pancreatitis requiring a 2-day prolonged hospitalization after fiducial placement. The patient presented worsening abdominal pain 18 hours after the placement of three fiducials in the pancreatic body mass. The patient's serum lipase was elevated to 420 IU/L. An abdominal CT scan showed mild swelling of the pancreas around the implanted fiducials. The patient was treated conservatively and recovered before the scheduled SBRT.
Five patients (15.6%) underwent same session EUS-guided fine needle aspiration (FNA) for tissue diagnosis at the time of fiducial placement without any procedure related complications.
Among the 32 patients who had fiducial placement under EUS guidance, 29 patients (90.6%) successfully underwent SBRT. Three patients did not undergo planned SBRT due to disease progression (n=2), transfer to another institution (n=1).
Generally, two or three fiducials were implanted into and around the tumor. A total of 94 fiducials were implanted in 32 patients, 34 using a transgastric approach and 60 using a transduodenal approach. The mean number of fiducials per patients was 2.94±0.24 (range, 2 to 3 seeds). Two patients with pancreatic head cancer were implanted with two fiducials because they already had a biliary metallic stent that can be used as reference marker, thereby allowing three-dimensional configuration with only two implanted fiducials.
Spontaneous fiducial migration was noted in one patients (3.1%). Three gold fiducials were inserted under EUS, and two fiducials were seen on subsequent planning CT; however, the ability to use the remaining fiducial markers for SBRT was adequate without requiring a repeat EUS procedure. Overall, fiducial migration occurred in one of 94 seeds placed (1.1%). There was no further reported fiducial migration throughout the course of radiation therapy. This was verified by comparing the cone beam CT images acquired before each day of therapy with the initial planning CT images.
In current study, we demonstrated the technical feasibility and safety of EUS-guided fiducial placement in either hepatic or pancreatic malignancy using a 19-gauge needle. The technical success rate of 100% demonstrates the feasibility of this technique for these cancers. Of the 32 patients who had EUS-guided fiducials implanted, 29 patients (90.6%) successfully underwent SBRT. We encountered no severe resistance while deploying the fiducial seeds. As the study was retrospective, it should be appreciated that preferential candidates for EUS-guided fiducial placement may have been included, thereby resulting in a high success rate. In addition, a previous study noted that failure to place a fiducial in the target lesion was attributable to an anatomical alteration or a limitation of the use of 5-mm-long fiducials.5,7 However, the present study included only one patient with surgically altered anatomy and used gold fiducials measuring 3 mm in length, potentially influencing our high success rate. In our experience, the fluoroscopic assistance was not necessary during the procedure of fiducial placement. We could identify the fiducials placed under EUS alone, thereby verifying the proper placement immediately.
There have been several published studies on the feasibility of EUS-guided fiducial placement for various mediastinal and abdominal malignancies.4-9 Four studies investigated the feasibility of EUS-guided fiducial placement using a 19-gauge FNA needle to deploy cylindrical gold seeds measuring 2.5 to 5 mm in length with 0.8 mm diameter, reporting a high success rate.5-7,9 Two studies demonstrated the feasibility of EUS-guided fiducial placement using a 22-gauge FNA needle to deploy gold coil fiducials measuring 10 mm in length with 0.35 mm diameter, offering potential advantages over the use of a 19-gauge needle.4,8 EUS-guided fine-needle injection using a 19-gauge needle performed in pancreatic lesions of the head and uncinate process is often challenging because of the acute angulation. Larghi et al.11 stated that the degree of deflection of the echoendoscope tip is the major factor responsible for bringing the target lesion into an appropriate position, which precludes extension of the needle from the accessory channel. For such hard to reach tumors, it is preferable to place the fiducial markers around the periphery of the tumor, rather than directly in the tumor, provided there is not a substantial difference between respiratory movement of the fiducials and the actual target tumor. Recently, one retrospective study comparing traditional fiducials (5-mm length, 0.8-mm diameter) and Visicoil fiducial (10-mm length, 0.35-mm diameter) demonstrated that there was no significant difference between the two fiducial types in terms of technical success, complications, and migration.12 However, it remains unclear whether the use of a 22-gauge needle instead of a 19-gauge needle affects the technical success and complication rates of the procedure until prospective randomized study is completed. It is also unclear whether the thinner caliber 0.35 mm fiducials affect the accurate tracking of the fiducials by the SBRT system compared to the standard 0.8 mm fiducials. Further prospective randomized studies are warranted to evaluate the technical success and complication rates of the EUS-guided fiducial placement using 19-gauge and 22-gauge needles. In previous studies, the target lesions for fiducial placement have been located in the mediastinum, abdomen and GI system including the pancreas, stomach, liver, and porta hepatis. The success rates for EUS-guided fiducial placement were reported to range from 85% to 100%.4-8 Reported procedure related complications were cholangitis (n=2), mild pancreatitis (n=1), fever (n=1), or minor bleeding (n=1).4-8,13 Based on previous literature and the current study, the overall technical success and complication rates of EUS-guided fiducial placement in GI malignancy were 96% and 2%, respectively (Table 2).
The fiducial placement may introduce air bubbles into the target lesion, which obscures EUS visualization and leads to difficulty in confirming fiducial placement. To prevent the introduction of air into the lesion, the stylet was withdrawn 7 to 8 mm while backloading the fiducial into the needle and was sealed in place with bone wax. No air bubbles were noted after fiducial deployment using this technique. Although the optimal seed number and location required for SBRT has not been established, we tried implanting at least two fiducials within or adjacent to the mass to account for the possibility of potential migration requiring repeat EUS procedures. In the present study, overall fiducial migration occurred in one of 94 seeds placed (1.0%).
In five cases, the lesion was presumed to be malignant on the basis of the imaging studies and the patient's history. Thus, five patients underwent same session EUS-FNA followed by fiducial placement without subsequent complication. Performing both procedures in the same session has several advantages such as expediting treatment and reducing the length of hospital stay. If EUS-FNA is planned for tissue diagnosis, our results indicate that it can be performed at the time of EUS-guided fiducial placement. Nonetheless, there remains a theoretical concern that performing both procedures simultaneously may cause trauma, resulting in procedure-related complications. Mild pancreatitis has been previously reported as a potential complication of EUS-guided fiducial placement with simultaneous EUS-guided celiac plexus neurolysis.5 For this issue, additional study may be considered.
Tumor seeding due to FNA is extremely rare. In percutaneous FNA under either US or CT guidance, the incidence ranges from 0.005% to 0.009%; however, in the case of EUS-FNA, it is considered to be even lower due to the shorter puncture path. Thus far, only three cases have been reported.14-16 Whether placement of the fiducial implantation within the tumor rather than adjacent to the tumor affects the seeding remains to be evaluated.
Following a previous report of procedure-related cholangitis,7,13 it is recommended that all patients receive prophylactic antibiotics, although strong evidence for this precaution, e.g., a prospective study, is lacking.17 In previous feasibility studies, all patients received an arbitrary 5-day course of antibiotics for infection prophylaxis.5,6,8 In the present study, all patients received a 1-day course of preprocedural and postprocedural intravenous antibiotics. There is ambiguity regarding the role of routine antibiotic prophylaxis prior to EUS-guided fiducial placement. More data are needed to evaluate the role of prophylactic antibiotics and the administering schedule of antibiotics if necessary.
Our study has several limitations. This was a retrospective study at a single tertiary medical center where all EUS procedures were undergone by a single experienced endosonographer. This study was not designed to evaluate a survival benefit or quality of life associated with EUS-guided fiducial placement as a method to support SBRT.
In conclusion, EUS-guided fiducial placement for SBRT in pancreatic and hepatic malignancy appears to be a safe and feasible technique when performed by an experienced endosonographer. This novel application of interventional EUS further expands the role of EUS in the multidisciplinary team approach to patients with pancreatic and hepatic malignancy. The fiducial markers would facilitate safe and accurate targeting of the tumor during SBRT.
Table 1 Patient and Procedural Characteristics for Endoscopic Ultrasonography-Guided Fiducial Placement
M, male; F, female; LN, lymph node.
Table 2 Summary of Published Studies and Current Study on Endoscopic Ultrasonography-Guided Fiducial Placement in Gastrointestinal Malignancy
P, prospective; R, retrospective; C, case series.