Indexed In : Science Citation Index Expanded(SCIE), MEDLINE,
Pubmed/Pubmed Central, Elsevier Bibliographic, Google Scholar,
Databases(Scopus & Embase), KCI, KoreaMed, DOAJ
Gut and Liver is an international journal of gastroenterology, focusing on the gastrointestinal tract, liver, biliary tree, pancreas, motility, and neurogastroenterology. Gut atnd Liver delivers up-to-date, authoritative papers on both clinical and research-based topics in gastroenterology. The Journal publishes original articles, case reports, brief communications, letters to the editor and invited review articles in the field of gastroenterology. The Journal is operated by internationally renowned editorial boards and designed to provide a global opportunity to promote academic developments in the field of gastroenterology and hepatology. +MORE
Yong Chan Lee |
Professor of Medicine Director, Gastrointestinal Research Laboratory Veterans Affairs Medical Center, Univ. California San Francisco San Francisco, USA |
Jong Pil Im | Seoul National University College of Medicine, Seoul, Korea |
Robert S. Bresalier | University of Texas M. D. Anderson Cancer Center, Houston, USA |
Steven H. Itzkowitz | Mount Sinai Medical Center, NY, USA |
All papers submitted to Gut and Liver are reviewed by the editorial team before being sent out for an external peer review to rule out papers that have low priority, insufficient originality, scientific flaws, or the absence of a message of importance to the readers of the Journal. A decision about these papers will usually be made within two or three weeks.
The remaining articles are usually sent to two reviewers. It would be very helpful if you could suggest a selection of reviewers and include their contact details. We may not always use the reviewers you recommend, but suggesting reviewers will make our reviewer database much richer; in the end, everyone will benefit. We reserve the right to return manuscripts in which no reviewers are suggested.
The final responsibility for the decision to accept or reject lies with the editors. In many cases, papers may be rejected despite favorable reviews because of editorial policy or a lack of space. The editor retains the right to determine publication priorities, the style of the paper, and to request, if necessary, that the material submitted be shortened for publication.
Stephanie Lok Hang Cheung , Anthony Yuen Bun Teoh
Correspondence to: Anthony Yuen Bun Teoh
ORCID https://orcid.org/0000-0002-1885-8035
E-mail anthonyteoh@surgery.cuhk.edu.hk
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Gut Liver 2022;16(2):190-197. https://doi.org/10.5009/gnl210010
Published online May 31, 2021, Published date March 15, 2022
Copyright © Gut and Liver.
The aim of this article is to review the different treatment options for malignant gastric outlet obstruction (GOO) and compare their safety and efficacy. We describe the history and evolution of gastrojejunostomy (GJ), endoscopic stenting and endoscopic ultrasonography-guided gastroenterostomy (EUS-GE) and analyze the current evidence regarding these three methods available in the literature, comparing their applicability, safety, complications and cost when used for the treatment of malignant GOO. We conclude that given the benefits of endoscopic techniques and the ability to place a stent away from the tumor, EUS-GE is a promising technique that may yield an efficacy similar to that of surgical GJ and duodenal stenting, with lower reintervention rates and fewer adverse events.
Keywords: Gastric outlet obstruction, Stents, Palliative care, Stomach neoplasm, Gastroenterostomy
Malignant gastric outlet obstruction (GOO) is the mechanical obstruction to gastric emptying often caused by malignancies of the stomach, duodenum or periampullary cancers. Patients with GOO often suffer from symptoms such as vomiting, nausea and reduced appetite which reduces the patient’s quality of life. GOO usually occurs when the malignancy is at an advanced stage and the aim of treatment is usually to palliate and re-establish oral intake to improve the quality of life.
Many factors play a role in the management of malignant GOO including the patient’s functional performance, stage of cancer, prognosis and quality of life. Currently available options include surgical gastrojejunostomy (GJ) and endoscopic stenting. Recently, endoscopic ultrasonography-guided gastroenterostomy (EUS-GE) with a lumen-apposing self-expandable metal stent (LAMS) has also been developed.1 This article aims to discuss the different treatment options for malignant GOO and compare their safety and efficacy.
Laparoscopic GJ (LGJ) is the standard for creating gastric bypass in malignant GOO and the procedure has been proven to be associated with better morbidity and mortality rates as compared to the open approach (Fig. 1). Studies have also showed lower rates of delayed gastric emptying and faster resumption of oral feeding with the laparoscopic technique.2 There are two main techniques in performing an LGJ,3 namely the antecolic and retrocolic method. The antecolic method is more commonly used as the retrocolic method is associated with a higher risk of internal herniation and absence of definite advantages. During the procedure, the gastrocolic omentum is first opened and the lesser sac entered to identify the distal stomach. A loop of small bowel 30 to 50 cm distal to the ligament of Treitz is then chosen for the GJ. Enterotomies are made with cautery in both the jejunum and stomach and a surgical stapler is then inserted into the enterotomies to create the anastomosis. The common enterotomy is then closed with sutures.
The major complications of LGJ include postoperative bleeding, anastomotic leak, delayed gastric emptying, and postoperative ileus.3 The procedure also possesses several advantages over open GJ (OGJ). Several studies have found that patients undergoing LGJ have a shorter median hospital stay with a difference of up to 10 days, shorter time to solid food intake (difference of 2 days),4 lower intraoperative blood loss,4 and reduced use of opiate analgesic.5,6
The first report of endoscopic self-expandable metallic stent (SEMS) placement for malignant GOO was published in 1992.7 Nowadays, endoscopic stenting is a largely popular alternative to surgical GJ, especially for patients who are not fit for surgery, patients who have recurrence of symptoms after surgery or patients with poorer prognosis (Fig. 2). The reported clinical success rate ranges between 84% and 93% with technical success between 93% and 97%.8
Careful selection of patients and evaluation of types of duodenal stricture is required before proceeding with duodenal stenting. Duodenal strictures are evaluated by endoscopy and also injection of contrast above the stricture and immediately downstream of stricture to assess morphology, length and degree of obstruction.
There are different types of duodenal stents available. SEMS consist of woven, knitted or laser cut metal mesh that exerts self-expanding forces until they reach maximum fixed diameter. SEMS are usually loaded inside a delivery device in a compressed form, passed to and deployed at the stricture site endoscopically under fluoroscopic guidance, and self-expand in around 24 to 48 hours.
Important characteristics of a stent include radial force which is the expanding force, and axial force which is the recovery force that keeps the stent straight after it is placed.9 The radial force is more important as this force keeps the gastric opening patent and prevent recurrence of GOO. Braided stents usually have a relatively low radial force (<150 N) that gradually decreased to 0 N during expansion, whereas plastic and metal stents that are non-braided manner usually have an initially high radial force (>300 N) followed by a steep decline to 0 N during expansion. The opposite is shown when comparing axial forces, where axial force was relatively high for braided SEMSs (>1.5 N), whereas non-braided SEMSs showed a much lower peak axial force (<1.5 N).10
There are mainly two types of stents: uncovered and covered stents, with their use depending on patient related variables, e.g., location of stenosis, involvement of bile duct and patient’s nutritional status.11 Uncovered stents reduce the risk of migration due to better tissue anchorage, and provides more flexibility thus can follow duodenal angulations more closely. Uncovered stents also allow for bile to flow through the stent interstices, so is more indicated in patients with previously placed biliary stents. However, these stents exert more pressure especially on acute angled stenosis which will cause mucosal hyperplasia and tissue ingrowth.11 Covered stents can be employed to treat tissue ingrowth into an uncover SEMS. The advantage is the prevention of recurrent obstruction but the disadvantage is a higher risk of stent migration which may cause intestinal obstruction requiring surgical interventions in the case of complete migration. Other disadvantages include relatively rigidity of stent and a higher cost.12 However, two randomized trials comparing covered and uncovered stents by Kim
The common complications of both types of duodenal stents include tumor overgrowth, ingrowth, food impaction, stent migration and biliary obstruction. Endoscopic intervention is usually needed in 20% to 25% of patients who develop complications. Rarer but more fatal complications can include bleeding and bowel wall perforation due to bare metal ends of stents.8,15
EUS-GE was first described in 2002.16 It has recently emerged as an alternative to both stenting and surgical gastroenterostomy for the treatment of malignant GOO. There are different types of technique for performing EUS-GE.17 All methods aim to create an EUS-guided bypass by inserting a LAMS from the gastric lumen to the small bowel distal to the obstruction. Systemic review has found that the technical and clinical success of EUS-GE is 93% and 91% respectively.18 Reintervention rate is 11.5%. Some complications from EUS-GE include peritonitis, perforation, abdominal pain and bleeding, with rates up to 11%.18
A duodenal tube is first inserted distal to the obstruction under endoscopic guidance (Fig. 3A). Diluted contrast is then injected into the duodenum and jejunum to distend the lumen. A linear echoendoscope is inserted into stomach identifying a duodenal or jejunal loop next to the stomach. EUS-guided transgastric puncture is then performed by the direct method using a cautery enhanced LAMS. The distal anchoring flange is deployed under EUS and fluoroscopic guide while the proximal flange is then deployed under endoscopic guidance. Avoidance in using a guidewire also reduces the chance of pushing the jejunum away during LAMS deployment.1,19
This method uses a retrieval/dilating balloon, single balloon overtube, nasobiliary drain and ultraslim endoscope (Fig. 3B, D, E). The area of stenosis is traversed by the endoscope itself or by guidewire under fluoroscopic guidance.20 The downstream method is where a large contrast filled balloon is placed in the jejunum using a guidewire, the inflated balloon is then located endosonographically and a transgastric puncture is performed with a needle with the goal of bursting the balloon and securing its position in the small bowel. A guidewire is then passed through the needle and the LAMS is deployed over this wire. This method is the basis of multiple other techniques including (1) the rendezvous method where the guidewire is pulled back through the duodenum obstruction and out of the mouth, then the LAMS is deployed over the guidewire; (2) the retrograde method where after the needle puncture and guidewire passage, a therapeutic endoscope is used to go pass the obstruction and the LAMS is deployed from the jejunal side into the stomach. This method reduces the risk of distal flange misdeployment because the stomach is less likely to be pushed away than the jejunum.1,19
A gastroscope is used to place a guidewire in the proximal jejunum bypassing the stricture (Figs. 3C, 4). A short-type balloon overtube is then placed in the stomach. A novel double balloon-occlusion catheter is passed over the guidewire and the two balloons (20 cm apart) are inflated, obstructing a segment of duodenum and jejunum. The obstructed segment is then filled with contrast material and methylene blue. Direct puncture with LAMS is then performed between the two balloons in this segment of small bowel and the LAMS is deployed. The advantage of this approach is that the jejunum is fixed between the balloons and can prevent migration while the LAMS is deployed; however, this method is not feasible if the jejunum and duodenum are not in close proximity to the gastric wall.
Ongoing studies are currently comparing the different methods for EUS-GE and more evidence is needed before we can establish an endoscopic standard for this procedure.1,19 Chen
Multiple studies have compared duodenal stenting versus surgical GJ (both OGJ and LGJ) in the treatment of GOO and have reached quite similar conclusions over the years (Table 1).22 Many different factors affect the choice between stenting and surgery, such as patient’s physical condition, life expectancy, disease status. Previous studies have found that patient with a longer life expectancy (e.g., >2 months in SUSTENT study), surgical GJ should be used.23 Other studies found that in patients with better performance status, surgical GJ is preferable as the median survival was significantly shorter after SEMS placement than after GJ (189 days vs 293 days, p=0.003).24,25
Table 1 Duodenal Stent versus Gastrojejunostomy
Author (year) | No. of patients | Technical success, % | Clinical success, % | Time to food tolerance, day | Hospital stay, day | Averse event, % | Reintervention, % | |
---|---|---|---|---|---|---|---|---|
Fiori | GJ | 9 | 100 | 100 | 6.3 | 10 | 11.1 | |
DS | 9 | 100 | 100 | 2.1 | 3.1 | 11.1 | ||
p-value | <0.01 | <0.01 | ||||||
Mehta | GJ | 14 | 100 | 100 | 11.4 | |||
DS | 13 | 92 | 92 | 5.2 | ||||
p-value | NS | NS | 0.02 | |||||
Jeurnink | GJ | 18 | 88 | 8 | 15 | 0 | ||
DS | 21 | 76 | 5 | 7 | 6 in 4 patients | |||
p-value | NS | <0.01 | 0.04 | 0.02 | <0.01 | |||
No | GJ | 41 | 97.6 | 95.1 | 5 | 18 | 12.2 | 5.5 |
DS | 113 | 95.8 | 87.5 | 2 | 16 | 44.4 | 43 | |
p-value | NS | NS | <0.01 | NS | <0.01 | <0.01 | ||
Espinel | GJ | 17 | 82.3 | 5 | 11.5 | 17.6 | ||
DS | 24 | 100 | 2.4 | 7.1 | 4 | |||
p-value | NS | <0.01 | <0.01 | |||||
Chandrasegaram | GJ | 19 | 9 | 25 | ||||
DS | 26 | 2 | 11 | |||||
p-value | <0.01 | <0.01 |
GJ, gastrojejunostomy; DS, duodenal stent; NS, not significant.
The presence of hypoalbuminemia in a patient can pose as a risk factor for surgical GJ as it affects wound and anastomosis healing. Presence of carcinomatosis with ascites is also an independent predictive factor for poor clinical success of stent placement.20 Meta-analysis has also shown that mean patency duration and survival lengths were significantly longer in the GJ group (169.2 and 193.4 days, respectively), compared to the endoscopic stenting group (96.5 and 119.9 days, respectively),26 and therefore if patient is expected to have longer survival and is fit for surgery, GJ should be chosen as choice of treatment.
In previous studies, the outcomes of stenting and surgery were compared. Firstly, stenting is associated with a higher initial clinical success, often measured by how rapid food intake is improved based on a GOO scoring system.23 Secondly, stenting offers a shorter length of hospital stay with a mean difference of up to 10 days.27-30 Thirdly, cost analysis has also shown that stenting is the significantly cheaper option amongst the two in one American and one Dutch study.31,32 Fourthly, some studies have found that the quality of life after stent placement is better, in terms of faster decrease in pain scores,23 and significant improvements in dysphagia, eating restrictions, dry mouth and reflux.33,34 However, there is no difference in terms of the rate of technical success and median survival.
However, stenting is associated with a higher major complication rate including bleeding and perforation, and a high risk of stent migration. Recurrent obstructive symptoms are common up to 27%, commonly due to stent obstruction commonly due to tumor ingrowth or over growth, leading to a higher reintervention rate and poorer longer outcomes.24 Reinterventions after stent complications can include endoscopy cleaning of stent, second stent placement or changing to GJ.23 Stent patency is significantly lower, even after insertion of a second stent when compared to the surgical group.25
On the other hand, complications associated with GJ include intra and postoperative hemorrhage, and dysfunction and leakage of anastomosis. Anastomotic stricture is also a possible complication and requires endoscopic stenting.25
One retrospective study has found that EUS-GE is associated with a lower rate of stent failure requiring reintervention (32.0% vs 8.3%, p=0.021) and a higher initial clinical success (96% vs 76%), when compared to duodenal stenting.35 In another study by Chen
Table 2 Endoscopic Ultrasound Guided Gastroenterostomy versus Duodenal Stent versus Gastrojejunostomy
Author (year) | No. of patients | Technical success, % | Clinical success, % | Averse event, % | Reintervention, % | |
---|---|---|---|---|---|---|
Chen | EUS-GE | 30 | 86.7 | 83.3 | 16.7 | 4.0 |
DS | 52 | 94.2 | 67.3 | 11.5 | 28.6 | |
p-value | 0.2 | 0.12 | 0.5 | 0.02 | ||
Ge | EUS-GE | 22 | 100 | 95.8 | 20.8 | 8.3 |
DS | 78 | 100 | 76.3 | 40.2 | 32.0 | |
p-value | 1.00 | 0.04 | 0.10 | 0.02 | ||
Khashab | EUS-GE | 30 | 86.7 | 86.7 | 13.3 | 3.4 |
DS | 60 | 96.7 | 70 | 18.3 | 43.4 | |
p-value | 0.07 | 0.08 | 0.55 | <0.01 | ||
Perez-Miranda | EUS-GE | 29 | 88 | 88 | 12 | |
DS | 22 | 100 | 100 | 41 | ||
p-value | 0.11 | 0.11 | 0.03 |
EUS-GE, endoscopic ultrasound guided gastroenterostomy; DS, duodenal stent.
In a study in 2017, higher technical success was found in OGJ (100% vs 87%), but clinical success, mean length of hospital stay, rate of GOO recurrence, and mean time to reintervention are all similar.37 In another study, significantly more adverse events are found in LGJ when compared to EUS-GE (41% vs 12%, p=0.03) including ileus, gastroparesis, and anastomotic leak requiring surgery.38 This study also found similar technical and clinical success and similar length of hospital stay between the two methods. Other advantages of EUS-GE include shorter procedural time when compared to the surgical approach (Table 2).
In conclusion, with the benefits of endoscopic technique, whilst being able to place a stent away from the tumor, EUS-GE is a promising technique that may provide similar efficacy to surgical GJ and duodenal stenting with lower reintervention rates, reduced adverse events.
A.Y.B.T. is a consultant for Boston Scientific, Cook, Taewoong and Microtech Medical Corporations. No other potential conflict of interest relevant to this article was reported.
Gut and Liver 2022; 16(2): 190-197
Published online March 15, 2022 https://doi.org/10.5009/gnl210010
Copyright © Gut and Liver.
Stephanie Lok Hang Cheung , Anthony Yuen Bun Teoh
Department of Surgery, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong Special Administrative Region, China
Correspondence to:Anthony Yuen Bun Teoh
ORCID https://orcid.org/0000-0002-1885-8035
E-mail anthonyteoh@surgery.cuhk.edu.hk
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
The aim of this article is to review the different treatment options for malignant gastric outlet obstruction (GOO) and compare their safety and efficacy. We describe the history and evolution of gastrojejunostomy (GJ), endoscopic stenting and endoscopic ultrasonography-guided gastroenterostomy (EUS-GE) and analyze the current evidence regarding these three methods available in the literature, comparing their applicability, safety, complications and cost when used for the treatment of malignant GOO. We conclude that given the benefits of endoscopic techniques and the ability to place a stent away from the tumor, EUS-GE is a promising technique that may yield an efficacy similar to that of surgical GJ and duodenal stenting, with lower reintervention rates and fewer adverse events.
Keywords: Gastric outlet obstruction, Stents, Palliative care, Stomach neoplasm, Gastroenterostomy
Malignant gastric outlet obstruction (GOO) is the mechanical obstruction to gastric emptying often caused by malignancies of the stomach, duodenum or periampullary cancers. Patients with GOO often suffer from symptoms such as vomiting, nausea and reduced appetite which reduces the patient’s quality of life. GOO usually occurs when the malignancy is at an advanced stage and the aim of treatment is usually to palliate and re-establish oral intake to improve the quality of life.
Many factors play a role in the management of malignant GOO including the patient’s functional performance, stage of cancer, prognosis and quality of life. Currently available options include surgical gastrojejunostomy (GJ) and endoscopic stenting. Recently, endoscopic ultrasonography-guided gastroenterostomy (EUS-GE) with a lumen-apposing self-expandable metal stent (LAMS) has also been developed.1 This article aims to discuss the different treatment options for malignant GOO and compare their safety and efficacy.
Laparoscopic GJ (LGJ) is the standard for creating gastric bypass in malignant GOO and the procedure has been proven to be associated with better morbidity and mortality rates as compared to the open approach (Fig. 1). Studies have also showed lower rates of delayed gastric emptying and faster resumption of oral feeding with the laparoscopic technique.2 There are two main techniques in performing an LGJ,3 namely the antecolic and retrocolic method. The antecolic method is more commonly used as the retrocolic method is associated with a higher risk of internal herniation and absence of definite advantages. During the procedure, the gastrocolic omentum is first opened and the lesser sac entered to identify the distal stomach. A loop of small bowel 30 to 50 cm distal to the ligament of Treitz is then chosen for the GJ. Enterotomies are made with cautery in both the jejunum and stomach and a surgical stapler is then inserted into the enterotomies to create the anastomosis. The common enterotomy is then closed with sutures.
The major complications of LGJ include postoperative bleeding, anastomotic leak, delayed gastric emptying, and postoperative ileus.3 The procedure also possesses several advantages over open GJ (OGJ). Several studies have found that patients undergoing LGJ have a shorter median hospital stay with a difference of up to 10 days, shorter time to solid food intake (difference of 2 days),4 lower intraoperative blood loss,4 and reduced use of opiate analgesic.5,6
The first report of endoscopic self-expandable metallic stent (SEMS) placement for malignant GOO was published in 1992.7 Nowadays, endoscopic stenting is a largely popular alternative to surgical GJ, especially for patients who are not fit for surgery, patients who have recurrence of symptoms after surgery or patients with poorer prognosis (Fig. 2). The reported clinical success rate ranges between 84% and 93% with technical success between 93% and 97%.8
Careful selection of patients and evaluation of types of duodenal stricture is required before proceeding with duodenal stenting. Duodenal strictures are evaluated by endoscopy and also injection of contrast above the stricture and immediately downstream of stricture to assess morphology, length and degree of obstruction.
There are different types of duodenal stents available. SEMS consist of woven, knitted or laser cut metal mesh that exerts self-expanding forces until they reach maximum fixed diameter. SEMS are usually loaded inside a delivery device in a compressed form, passed to and deployed at the stricture site endoscopically under fluoroscopic guidance, and self-expand in around 24 to 48 hours.
Important characteristics of a stent include radial force which is the expanding force, and axial force which is the recovery force that keeps the stent straight after it is placed.9 The radial force is more important as this force keeps the gastric opening patent and prevent recurrence of GOO. Braided stents usually have a relatively low radial force (<150 N) that gradually decreased to 0 N during expansion, whereas plastic and metal stents that are non-braided manner usually have an initially high radial force (>300 N) followed by a steep decline to 0 N during expansion. The opposite is shown when comparing axial forces, where axial force was relatively high for braided SEMSs (>1.5 N), whereas non-braided SEMSs showed a much lower peak axial force (<1.5 N).10
There are mainly two types of stents: uncovered and covered stents, with their use depending on patient related variables, e.g., location of stenosis, involvement of bile duct and patient’s nutritional status.11 Uncovered stents reduce the risk of migration due to better tissue anchorage, and provides more flexibility thus can follow duodenal angulations more closely. Uncovered stents also allow for bile to flow through the stent interstices, so is more indicated in patients with previously placed biliary stents. However, these stents exert more pressure especially on acute angled stenosis which will cause mucosal hyperplasia and tissue ingrowth.11 Covered stents can be employed to treat tissue ingrowth into an uncover SEMS. The advantage is the prevention of recurrent obstruction but the disadvantage is a higher risk of stent migration which may cause intestinal obstruction requiring surgical interventions in the case of complete migration. Other disadvantages include relatively rigidity of stent and a higher cost.12 However, two randomized trials comparing covered and uncovered stents by Kim
The common complications of both types of duodenal stents include tumor overgrowth, ingrowth, food impaction, stent migration and biliary obstruction. Endoscopic intervention is usually needed in 20% to 25% of patients who develop complications. Rarer but more fatal complications can include bleeding and bowel wall perforation due to bare metal ends of stents.8,15
EUS-GE was first described in 2002.16 It has recently emerged as an alternative to both stenting and surgical gastroenterostomy for the treatment of malignant GOO. There are different types of technique for performing EUS-GE.17 All methods aim to create an EUS-guided bypass by inserting a LAMS from the gastric lumen to the small bowel distal to the obstruction. Systemic review has found that the technical and clinical success of EUS-GE is 93% and 91% respectively.18 Reintervention rate is 11.5%. Some complications from EUS-GE include peritonitis, perforation, abdominal pain and bleeding, with rates up to 11%.18
A duodenal tube is first inserted distal to the obstruction under endoscopic guidance (Fig. 3A). Diluted contrast is then injected into the duodenum and jejunum to distend the lumen. A linear echoendoscope is inserted into stomach identifying a duodenal or jejunal loop next to the stomach. EUS-guided transgastric puncture is then performed by the direct method using a cautery enhanced LAMS. The distal anchoring flange is deployed under EUS and fluoroscopic guide while the proximal flange is then deployed under endoscopic guidance. Avoidance in using a guidewire also reduces the chance of pushing the jejunum away during LAMS deployment.1,19
This method uses a retrieval/dilating balloon, single balloon overtube, nasobiliary drain and ultraslim endoscope (Fig. 3B, D, E). The area of stenosis is traversed by the endoscope itself or by guidewire under fluoroscopic guidance.20 The downstream method is where a large contrast filled balloon is placed in the jejunum using a guidewire, the inflated balloon is then located endosonographically and a transgastric puncture is performed with a needle with the goal of bursting the balloon and securing its position in the small bowel. A guidewire is then passed through the needle and the LAMS is deployed over this wire. This method is the basis of multiple other techniques including (1) the rendezvous method where the guidewire is pulled back through the duodenum obstruction and out of the mouth, then the LAMS is deployed over the guidewire; (2) the retrograde method where after the needle puncture and guidewire passage, a therapeutic endoscope is used to go pass the obstruction and the LAMS is deployed from the jejunal side into the stomach. This method reduces the risk of distal flange misdeployment because the stomach is less likely to be pushed away than the jejunum.1,19
A gastroscope is used to place a guidewire in the proximal jejunum bypassing the stricture (Figs. 3C, 4). A short-type balloon overtube is then placed in the stomach. A novel double balloon-occlusion catheter is passed over the guidewire and the two balloons (20 cm apart) are inflated, obstructing a segment of duodenum and jejunum. The obstructed segment is then filled with contrast material and methylene blue. Direct puncture with LAMS is then performed between the two balloons in this segment of small bowel and the LAMS is deployed. The advantage of this approach is that the jejunum is fixed between the balloons and can prevent migration while the LAMS is deployed; however, this method is not feasible if the jejunum and duodenum are not in close proximity to the gastric wall.
Ongoing studies are currently comparing the different methods for EUS-GE and more evidence is needed before we can establish an endoscopic standard for this procedure.1,19 Chen
Multiple studies have compared duodenal stenting versus surgical GJ (both OGJ and LGJ) in the treatment of GOO and have reached quite similar conclusions over the years (Table 1).22 Many different factors affect the choice between stenting and surgery, such as patient’s physical condition, life expectancy, disease status. Previous studies have found that patient with a longer life expectancy (e.g., >2 months in SUSTENT study), surgical GJ should be used.23 Other studies found that in patients with better performance status, surgical GJ is preferable as the median survival was significantly shorter after SEMS placement than after GJ (189 days vs 293 days, p=0.003).24,25
Table 1 . Duodenal Stent versus Gastrojejunostomy.
Author (year) | No. of patients | Technical success, % | Clinical success, % | Time to food tolerance, day | Hospital stay, day | Averse event, % | Reintervention, % | |
---|---|---|---|---|---|---|---|---|
Fiori | GJ | 9 | 100 | 100 | 6.3 | 10 | 11.1 | |
DS | 9 | 100 | 100 | 2.1 | 3.1 | 11.1 | ||
p-value | <0.01 | <0.01 | ||||||
Mehta | GJ | 14 | 100 | 100 | 11.4 | |||
DS | 13 | 92 | 92 | 5.2 | ||||
p-value | NS | NS | 0.02 | |||||
Jeurnink | GJ | 18 | 88 | 8 | 15 | 0 | ||
DS | 21 | 76 | 5 | 7 | 6 in 4 patients | |||
p-value | NS | <0.01 | 0.04 | 0.02 | <0.01 | |||
No | GJ | 41 | 97.6 | 95.1 | 5 | 18 | 12.2 | 5.5 |
DS | 113 | 95.8 | 87.5 | 2 | 16 | 44.4 | 43 | |
p-value | NS | NS | <0.01 | NS | <0.01 | <0.01 | ||
Espinel | GJ | 17 | 82.3 | 5 | 11.5 | 17.6 | ||
DS | 24 | 100 | 2.4 | 7.1 | 4 | |||
p-value | NS | <0.01 | <0.01 | |||||
Chandrasegaram | GJ | 19 | 9 | 25 | ||||
DS | 26 | 2 | 11 | |||||
p-value | <0.01 | <0.01 |
GJ, gastrojejunostomy; DS, duodenal stent; NS, not significant..
The presence of hypoalbuminemia in a patient can pose as a risk factor for surgical GJ as it affects wound and anastomosis healing. Presence of carcinomatosis with ascites is also an independent predictive factor for poor clinical success of stent placement.20 Meta-analysis has also shown that mean patency duration and survival lengths were significantly longer in the GJ group (169.2 and 193.4 days, respectively), compared to the endoscopic stenting group (96.5 and 119.9 days, respectively),26 and therefore if patient is expected to have longer survival and is fit for surgery, GJ should be chosen as choice of treatment.
In previous studies, the outcomes of stenting and surgery were compared. Firstly, stenting is associated with a higher initial clinical success, often measured by how rapid food intake is improved based on a GOO scoring system.23 Secondly, stenting offers a shorter length of hospital stay with a mean difference of up to 10 days.27-30 Thirdly, cost analysis has also shown that stenting is the significantly cheaper option amongst the two in one American and one Dutch study.31,32 Fourthly, some studies have found that the quality of life after stent placement is better, in terms of faster decrease in pain scores,23 and significant improvements in dysphagia, eating restrictions, dry mouth and reflux.33,34 However, there is no difference in terms of the rate of technical success and median survival.
However, stenting is associated with a higher major complication rate including bleeding and perforation, and a high risk of stent migration. Recurrent obstructive symptoms are common up to 27%, commonly due to stent obstruction commonly due to tumor ingrowth or over growth, leading to a higher reintervention rate and poorer longer outcomes.24 Reinterventions after stent complications can include endoscopy cleaning of stent, second stent placement or changing to GJ.23 Stent patency is significantly lower, even after insertion of a second stent when compared to the surgical group.25
On the other hand, complications associated with GJ include intra and postoperative hemorrhage, and dysfunction and leakage of anastomosis. Anastomotic stricture is also a possible complication and requires endoscopic stenting.25
One retrospective study has found that EUS-GE is associated with a lower rate of stent failure requiring reintervention (32.0% vs 8.3%, p=0.021) and a higher initial clinical success (96% vs 76%), when compared to duodenal stenting.35 In another study by Chen
Table 2 . Endoscopic Ultrasound Guided Gastroenterostomy versus Duodenal Stent versus Gastrojejunostomy.
Author (year) | No. of patients | Technical success, % | Clinical success, % | Averse event, % | Reintervention, % | |
---|---|---|---|---|---|---|
Chen | EUS-GE | 30 | 86.7 | 83.3 | 16.7 | 4.0 |
DS | 52 | 94.2 | 67.3 | 11.5 | 28.6 | |
p-value | 0.2 | 0.12 | 0.5 | 0.02 | ||
Ge | EUS-GE | 22 | 100 | 95.8 | 20.8 | 8.3 |
DS | 78 | 100 | 76.3 | 40.2 | 32.0 | |
p-value | 1.00 | 0.04 | 0.10 | 0.02 | ||
Khashab | EUS-GE | 30 | 86.7 | 86.7 | 13.3 | 3.4 |
DS | 60 | 96.7 | 70 | 18.3 | 43.4 | |
p-value | 0.07 | 0.08 | 0.55 | <0.01 | ||
Perez-Miranda | EUS-GE | 29 | 88 | 88 | 12 | |
DS | 22 | 100 | 100 | 41 | ||
p-value | 0.11 | 0.11 | 0.03 |
EUS-GE, endoscopic ultrasound guided gastroenterostomy; DS, duodenal stent..
In a study in 2017, higher technical success was found in OGJ (100% vs 87%), but clinical success, mean length of hospital stay, rate of GOO recurrence, and mean time to reintervention are all similar.37 In another study, significantly more adverse events are found in LGJ when compared to EUS-GE (41% vs 12%, p=0.03) including ileus, gastroparesis, and anastomotic leak requiring surgery.38 This study also found similar technical and clinical success and similar length of hospital stay between the two methods. Other advantages of EUS-GE include shorter procedural time when compared to the surgical approach (Table 2).
In conclusion, with the benefits of endoscopic technique, whilst being able to place a stent away from the tumor, EUS-GE is a promising technique that may provide similar efficacy to surgical GJ and duodenal stenting with lower reintervention rates, reduced adverse events.
A.Y.B.T. is a consultant for Boston Scientific, Cook, Taewoong and Microtech Medical Corporations. No other potential conflict of interest relevant to this article was reported.
Table 1 Duodenal Stent versus Gastrojejunostomy
Author (year) | No. of patients | Technical success, % | Clinical success, % | Time to food tolerance, day | Hospital stay, day | Averse event, % | Reintervention, % | |
---|---|---|---|---|---|---|---|---|
Fiori | GJ | 9 | 100 | 100 | 6.3 | 10 | 11.1 | |
DS | 9 | 100 | 100 | 2.1 | 3.1 | 11.1 | ||
p-value | <0.01 | <0.01 | ||||||
Mehta | GJ | 14 | 100 | 100 | 11.4 | |||
DS | 13 | 92 | 92 | 5.2 | ||||
p-value | NS | NS | 0.02 | |||||
Jeurnink | GJ | 18 | 88 | 8 | 15 | 0 | ||
DS | 21 | 76 | 5 | 7 | 6 in 4 patients | |||
p-value | NS | <0.01 | 0.04 | 0.02 | <0.01 | |||
No | GJ | 41 | 97.6 | 95.1 | 5 | 18 | 12.2 | 5.5 |
DS | 113 | 95.8 | 87.5 | 2 | 16 | 44.4 | 43 | |
p-value | NS | NS | <0.01 | NS | <0.01 | <0.01 | ||
Espinel | GJ | 17 | 82.3 | 5 | 11.5 | 17.6 | ||
DS | 24 | 100 | 2.4 | 7.1 | 4 | |||
p-value | NS | <0.01 | <0.01 | |||||
Chandrasegaram | GJ | 19 | 9 | 25 | ||||
DS | 26 | 2 | 11 | |||||
p-value | <0.01 | <0.01 |
GJ, gastrojejunostomy; DS, duodenal stent; NS, not significant.
Table 2 Endoscopic Ultrasound Guided Gastroenterostomy versus Duodenal Stent versus Gastrojejunostomy
Author (year) | No. of patients | Technical success, % | Clinical success, % | Averse event, % | Reintervention, % | |
---|---|---|---|---|---|---|
Chen | EUS-GE | 30 | 86.7 | 83.3 | 16.7 | 4.0 |
DS | 52 | 94.2 | 67.3 | 11.5 | 28.6 | |
p-value | 0.2 | 0.12 | 0.5 | 0.02 | ||
Ge | EUS-GE | 22 | 100 | 95.8 | 20.8 | 8.3 |
DS | 78 | 100 | 76.3 | 40.2 | 32.0 | |
p-value | 1.00 | 0.04 | 0.10 | 0.02 | ||
Khashab | EUS-GE | 30 | 86.7 | 86.7 | 13.3 | 3.4 |
DS | 60 | 96.7 | 70 | 18.3 | 43.4 | |
p-value | 0.07 | 0.08 | 0.55 | <0.01 | ||
Perez-Miranda | EUS-GE | 29 | 88 | 88 | 12 | |
DS | 22 | 100 | 100 | 41 | ||
p-value | 0.11 | 0.11 | 0.03 |