Indexed In : Science Citation Index Expanded(SCIE), MEDLINE,
Pubmed/Pubmed Central, Elsevier Bibliographic, Google Scholar,
Databases(Scopus & Embase), KCI, KoreaMed, DOAJ
Gut and Liver is an international journal of gastroenterology, focusing on the gastrointestinal tract, liver, biliary tree, pancreas, motility, and neurogastroenterology. Gut atnd Liver delivers up-to-date, authoritative papers on both clinical and research-based topics in gastroenterology. The Journal publishes original articles, case reports, brief communications, letters to the editor and invited review articles in the field of gastroenterology. The Journal is operated by internationally renowned editorial boards and designed to provide a global opportunity to promote academic developments in the field of gastroenterology and hepatology. +MORE
Yong Chan Lee |
Professor of Medicine Director, Gastrointestinal Research Laboratory Veterans Affairs Medical Center, Univ. California San Francisco San Francisco, USA |
Jong Pil Im | Seoul National University College of Medicine, Seoul, Korea |
Robert S. Bresalier | University of Texas M. D. Anderson Cancer Center, Houston, USA |
Steven H. Itzkowitz | Mount Sinai Medical Center, NY, USA |
All papers submitted to Gut and Liver are reviewed by the editorial team before being sent out for an external peer review to rule out papers that have low priority, insufficient originality, scientific flaws, or the absence of a message of importance to the readers of the Journal. A decision about these papers will usually be made within two or three weeks.
The remaining articles are usually sent to two reviewers. It would be very helpful if you could suggest a selection of reviewers and include their contact details. We may not always use the reviewers you recommend, but suggesting reviewers will make our reviewer database much richer; in the end, everyone will benefit. We reserve the right to return manuscripts in which no reviewers are suggested.
The final responsibility for the decision to accept or reject lies with the editors. In many cases, papers may be rejected despite favorable reviews because of editorial policy or a lack of space. The editor retains the right to determine publication priorities, the style of the paper, and to request, if necessary, that the material submitted be shortened for publication.
Dong Seok Lee1,2 , Ji Yong Ahn2 , Gin Hyug Lee2
Correspondence to: Gin Hyug Leea and Ji Yong Ahnb
Department of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Korea
aTel: +82-2-3010-3986, Fax: +82-2-476-0824, E-mail: jhlee409@amc.seoul.kr
bTel: +82-2-3010-5667, Fax: +82-2-476-0824, E-mail: ji110@hanmail.net
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Gut Liver 2019;13(4):415-420. https://doi.org/10.5009/gnl18389
Published online July 15, 2019, Published date April 17, 2019
Copyright © Gut and Liver.
We used 3-dimensional (3D) printing technology to create a new hemostasis simulator for the stomach and investigated its efficacy and realism in endoscopic hemostasis training. A new stomach hemostasis simulator, with two hemostasis modules for hemoclipping and injection, was constructed using a 3D printer. Twenty-one endoscopists, including 11 first-year fellows (beginner group) and 10 faculty members (expert group), tested the performance of the simulator. We recorded and reviewed five training sessions and evaluated the simulator with questionnaires using a 7-point Likert scale. The mean evaluation score of the expert group was 6.3±0.5 for the hemoclipping module and 6.0±0.6 for the injection module. The expert group strongly agreed that endoscopic handling in the simulator was realistic and reasonable for hemostasis training. The mean procedure time for hemoclipping was 72.7±7.1 seconds for the beginner group and 19.7±1.2 seconds for the expert group. The mean procedure time for injection was 92.1±9.8 seconds for the beginner group and 36.3±2 seconds for the expert group. The procedure time of beginner group became shorter with repetition and was significantly lower by the fifth trial. A new 3D-printed hemostasis simulator is capable of hemostasis training and can very effectively train beginners before they perform the procedure in patients with gastrointestinal bleeding.Background/Aims
Methods
Results
Conclusions
Keywords: Printing, three-dimensional, Endoscopy, Simulator, Hemostasis, Education
The annual incidence of upper gastrointestinal (GI) bleeding ranges from 48 to 160 cases per 100,000 adults, with mortality rates as high as 10% to 14%.1 Despite advances in endoscopy and medical treatment, the mortality rates of GI bleeding have been largely unchanged in recent decades.2 Moreover, GI bleeding can be a life-threatening event in older patients with co-morbidities and can thus represent a considerable problem in an aging society. Among several endoscopic techniques which are available for hemostasis, epinephrine injection is the easiest and effective approach but rebleeding occurs in many cases. Therefore, to reduce the risk of rebleeding, it should be combined with another method such as hemoclipping and/or thermocoagulation. Many studies and meta-analyses have examined the efficacy of the available endoscopic techniques in patients with high-risk lesions.3,4
Although technical skill and endoscopic experience are the most important determinants of successful hemostasis, endoscopic experience can typically only be obtained by practice with real bleeding cases. Thus, various simulators have been developed to mimic acute bleeding situations to reduce the burden on the practitioner and to improve patient safety. However, they are not actively used because of various disadvantages compared with real situations. The first to be introduced were computer simulators for colonoscopy training, with more recent development of various powerful simulators such as the ENDO-X (Medical X Corp., Miami, FL, USA) and GI-Mentor (Simbionix Ltd., Israel).5–7 The ENDO-X and GI-Mentor perform various simulations, including endoscopic hemostasis, but these virtual devices are different in elasticity from humans and tactile sensation using hemostatic materials, and expensive to purchase. Animal simulators such as pigs and dogs have been used to simulate upper GI hemorrhage8,9 but these simulators are limited by their reusability and ethical concerns.
Therefore, to overcome the limitations of the previous endoscopic hemostasis simulators, we developed a new simulator using 3-dimensional (3D) printing technology.
The study was approved by the Institutional Review Board of Asan Medical Center (IRB number: 2016–0302) and performed in accordance with the principles of the Declaration of Helsinki. Twenty-one endoscopists (10 experts and 11 beginners) were recruited to assess the validity of the simulator in June 2017 at Asan Medical Center, Seoul, Korea. The expert group members were staff with experience of more than 50,000 cases of screening endoscopy and 1,000 cases of hemostasis. Eleven beginner group members were first-year clinical fellows with experience of more than 800 cases of EGD and 200 cases of colonoscopy.
The new simulator comprises the main body of the upper GI tract, two hemostasis modules for hemoclipping and injection therapy, and a digital peristaltic pump (EMP-600A; EMS Tech, Yongin, Korea) for supplying artificial blood. The main body of the simulator was modified from previous 3D-printed training simulator for endoscopic biopsy in the stomach (this paper is scheduled to be published). The stereolithographic files of the hard part of the two hemostasis modules and the molds of the soft part were produced with the 3D modeling program, Netfabb professional version 5 (Netfabb GmbH, Lupburg, Germany), and printed with the stereolithography 3D printer, Form 2 (Formlabs Inc, Somerville, MA, USA). The soft part of the hemostasis modules has produced by molding shell technique using the soft silicone, Platsil Gel-10 (Polytek, Easton, PA, USA). After assembly of each part, the two modules were inserted into the two holes of the main body, one on the anterior wall side of the proximal body and the other on the anterior wall side of the antrum. The outer part of each module has two tubes connected to the pump (commercial infusion pump for patients) supplying the artificial blood (Fig. 1). Any conventional endoscopic equipment such as esophagogastroduodenoscopes, hemoclips, and injectors can be used in the new simulator. Our test of endoscopic hemostasis was conducted with a standard single channel endoscope (GIF-Q260J; Olympus Co. Ltd., Tokyo, Japan), hemoclip (QuickClip Pro; Olympus Co. Ltd), and injector (NM-400Y-0423; Olympus Co. Ltd). The simulator has designed and produced by an experienced endoscopist.
A hemoclipping module was designed for endoscopic hemo-clipping training. The hemoclipping module comprises 16 protruding parts (Fig. 2A). The protruding parts were sealed with a metal pin; removal of the metal pin allows artificial blood to pump in a manner similar to that of real blood from a vessel (Fig. 2B). When the hemoclip is properly positioned, the flow of artificial blood stops (Fig. 2C).
The injection module was designed for the injection of normal saline near the bleeding site. The inner part of the injection module has two stacked chambers and the outer part is made of methacrylic acid ester cured by photo initiator (Fig. 3A). The bleeding pore is connected to the inner chamber and the flow of artificial blood stops when about 2 to 4 mL of normal saline is injected into the outer chamber (Fig. 3B and C).
The primary outcome measure was suitability of the simulator for hemostasis training. The expert group assessed the suitability of the simulator for hemostasis training. Only expert group members were selected as evaluators to rule out as much subjectivity as possible. After testing the simulator, self-administered questionnaires were given to the participants to estimate the efficacy of the hemostasis simulator using a 7-point Likert scale, where 1 indicates poor and 7 indicates excellent. The questions covered the following topics: (1) Handling of simulator is similarity with actual case; (2) Simulator is reasonable for hemostasis training; (3) Working with the simulator will improves trainee’s skills; (4) Training with the simulator reduces the risk for patients; (5) I recommend that the simulator be used in hemostasis training. The secondary outcome measure was the procedure time for new hemostasis simulator.
Statistical analysis was performed using SPSS software, version 21 (IBM Corp., Armonk, NY, USA). Continuous variables are reported as medians with interquartile ranges and/or as means±standard deviations. Descriptive statistics were used to describe data, such as reusability and similarity.
All participants completed the hemoclipping and injection methods successfully. There were no malfunctions during the test.
The 10 experts estimated the realism level of the new hemo-stasis simulator using a 7-point Likert scale (Table 1). The mean score of the hemoclipping module was 6.3±0.5 and the that of the injection module was 6.0±0.6. Participants strongly agreed that endoscopic handling in the simulator was realistic and reasonable for endoscopic training. Notably, all of the participants felt that this training could reduce the risk for patients.
Each group tested the hemostasis simulator. To compare the learning effect of the hemostasis simulator, the procedure times of each group were measured five times. Procedure time sharply decreased after each trial in the beginner group (Fig. 4). The mean procedure time per bleeding hole with hemoclipping module was 72.7±7.1 seconds for beginner group and 19.7±1.2 seconds for expert group (Table 2). The number of clips used for the hemostasis was 1 per person. The mean procedure time for the injection module was 92.1±9.8 seconds for beginner group and 36.3±2 seconds for expert group. The material used for the injection was a mean 4±1 mL of normal saline.
We developed a new endoscopic hemostasis simulator for hemoclipping and injection. The simulator is fully compatible with conventional endoscopic equipment and can be made from a 3D printer and basic materials. Ten experts evaluated the new simulator and agreed that it is effective for training. The approximate price of the simulator is $200, and the price may become lower depending on the production quantity. Because of the low cost and compatibility, endoscopists in hospitals without sufficient experience can easily receive training, which should significantly improve patient safety.
We assessed the efficacy and realism of a novel 3D endoscopic hemostasis simulator, with differing levels of experience. Procedure time became shorter as the participants repeated the training sessions. The expert group strongly agreed that this simulator was a useful tool for improving endoscopic hemostasis skills of trainee without any risks to patients.
Endoscopic hemostasis is a well-established procedure for the treatment of GI bleeding and effectively reduces morbidity and mortality.10 In previous studies, animal models have been used in training to simulate upper GI hemorrhage.8,9 However, this approach is not widely used due to problems with cost, usability, safety, ethics, and reusability.11 Because of ethical concerns, realistic
3D printing has been used in various fields of medicine. 3D-printed materials can be used to train various procedures, such as in orthopedics, spinal surgery, neurosurgery, and cardiac surgery.16,17 Recently, a simulator for endoscopic training and biopsy was developed and evaluated in our center.18,19 Because this first stomach biopsy simulator was made from a rectangular plastic box, it provides a different feeling compared with the actual stomach. Thus, a second stomach biopsy simulator was made with a 3D printer to have the same shape as the actual stomach. The second stomach biopsy simulator was found to be an effective and realistic method for improving biopsy skills without any risk to patients (unpublished data). Based on this new 3D printing technology and our experience, we created a new simulator for bleeding control to overcome the disadvantages of existing simulators.
This study had several limitations of note. First, gastric movement due to the heartbeat and respiration were not reproduced; thus, endoscopic hemostasis would have been easier than in a real patient. Second, there was a possible bias in evaluating the simulator using questionnaires. Third, the level of elasticity is different from real stomach. Nevertheless, our 3D-printed simulator has various benefits for endoscopic hemostasis training and could be the basis for a more complex simulator that overcomes the above drawbacks. Fourth, our simulator was not compared to other simulators and we could not include external expert groups for test. Therefore, there is possibility of subjectivity in the test for this simulator. To overcome this limitation, we tried to consist the evaluators as experts of our center.
In conclusion, the new simulator described herein has advantages over the previous hemostasis simulators due to improved realism, cost-effectiveness, and reusability. We believe that this new simulator could be applied to endoscopic hemostasis training in many centers and we have plans to improve it further by listening to user feedbacks and by including other hemostatic methods such as coagulation and argon plasma coagulation modules.
No potential conflict of interest relevant to this article was reported.
This study was supported by a grant (2016-7021) from the Asan Institute for Life Sciences, Asan Medical Center, Seoul, Korea.
Study concept and design, data acquisition, data analysis and interpretation, drafting of the manuscript: D.S.L. Critical revision of the manuscript for important intellectual content, obtained funding, administrative, technical, or material support, study supervision: G.H.L., J.Y.A.
Mean Scores of the Answer to the Question for the Hemosta-sis Simulator Using a 7-Point Likert Scale
Index | Hemoclipping | Injection |
---|---|---|
Handling of simulator is similarity with actual case | 6.1±0.4 | 6.4±0.5 |
Simulator is reasonable for hemostasis training | 6.0±0.5 | 6.4±0.4 |
Working with the simulator will improves trainee’s skills | 6.3±0.5 | 6.7±0.5 |
Training with the simulator reduces the risk for patients | 6.1±0.7 | 6.9±0.5 |
I recommend that the simulator be used in hemostasis training | 6.1±0.7 | 6.9±0.5 |
Procedure Completing Times with the New Hemostasis Simulator According to the Experience Level of the Endoscopist
Hemoclipping | Injection | |||
---|---|---|---|---|
Beginner group (n=11) | Expert group (n=10) | Beginner group (n=11) | Expert group (n=10) | |
1st trial | 116.1±15.3 | 25.1±1.2 | 161.3±13.4 | 46±3.1 |
2nd trial | 96.4±6.1 | 21.2±1.9 | 118.2±9.3 | 36.4±2 |
3rd trial | 65.8±3.3 | 18±1 | 77±10.7 | 33.6±1.6 |
4th trial | 54.8±6.9 | 17.7±1 | 61.1±8.2 | 32.9±2.2 |
5th trial | 30.5±4.1 | 16.6±1 | 43±7.2 | 32.4±1.5 |
Mean of 5 trials | 72.7±7.1 | 19.7±1.2 | 92.1±9.8 | 36.3±2 |
Gut and Liver 2019; 13(4): 415-420
Published online April 17, 2019 https://doi.org/10.5009/gnl18389
Copyright © Gut and Liver.
Dong Seok Lee1,2 , Ji Yong Ahn2 , Gin Hyug Lee2
1Department of Gastroenterology, SMG-SNU Boramae Medical Center, Seoul National University of College of Medicine, and 2Department of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
Correspondence to:Gin Hyug Leea and Ji Yong Ahnb
Department of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Korea
aTel: +82-2-3010-3986, Fax: +82-2-476-0824, E-mail: jhlee409@amc.seoul.kr
bTel: +82-2-3010-5667, Fax: +82-2-476-0824, E-mail: ji110@hanmail.net
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
We used 3-dimensional (3D) printing technology to create a new hemostasis simulator for the stomach and investigated its efficacy and realism in endoscopic hemostasis training. A new stomach hemostasis simulator, with two hemostasis modules for hemoclipping and injection, was constructed using a 3D printer. Twenty-one endoscopists, including 11 first-year fellows (beginner group) and 10 faculty members (expert group), tested the performance of the simulator. We recorded and reviewed five training sessions and evaluated the simulator with questionnaires using a 7-point Likert scale. The mean evaluation score of the expert group was 6.3±0.5 for the hemoclipping module and 6.0±0.6 for the injection module. The expert group strongly agreed that endoscopic handling in the simulator was realistic and reasonable for hemostasis training. The mean procedure time for hemoclipping was 72.7±7.1 seconds for the beginner group and 19.7±1.2 seconds for the expert group. The mean procedure time for injection was 92.1±9.8 seconds for the beginner group and 36.3±2 seconds for the expert group. The procedure time of beginner group became shorter with repetition and was significantly lower by the fifth trial. A new 3D-printed hemostasis simulator is capable of hemostasis training and can very effectively train beginners before they perform the procedure in patients with gastrointestinal bleeding.Background/Aims
Methods
Results
Conclusions
Keywords: Printing, three-dimensional, Endoscopy, Simulator, Hemostasis, Education
The annual incidence of upper gastrointestinal (GI) bleeding ranges from 48 to 160 cases per 100,000 adults, with mortality rates as high as 10% to 14%.1 Despite advances in endoscopy and medical treatment, the mortality rates of GI bleeding have been largely unchanged in recent decades.2 Moreover, GI bleeding can be a life-threatening event in older patients with co-morbidities and can thus represent a considerable problem in an aging society. Among several endoscopic techniques which are available for hemostasis, epinephrine injection is the easiest and effective approach but rebleeding occurs in many cases. Therefore, to reduce the risk of rebleeding, it should be combined with another method such as hemoclipping and/or thermocoagulation. Many studies and meta-analyses have examined the efficacy of the available endoscopic techniques in patients with high-risk lesions.3,4
Although technical skill and endoscopic experience are the most important determinants of successful hemostasis, endoscopic experience can typically only be obtained by practice with real bleeding cases. Thus, various simulators have been developed to mimic acute bleeding situations to reduce the burden on the practitioner and to improve patient safety. However, they are not actively used because of various disadvantages compared with real situations. The first to be introduced were computer simulators for colonoscopy training, with more recent development of various powerful simulators such as the ENDO-X (Medical X Corp., Miami, FL, USA) and GI-Mentor (Simbionix Ltd., Israel).5–7 The ENDO-X and GI-Mentor perform various simulations, including endoscopic hemostasis, but these virtual devices are different in elasticity from humans and tactile sensation using hemostatic materials, and expensive to purchase. Animal simulators such as pigs and dogs have been used to simulate upper GI hemorrhage8,9 but these simulators are limited by their reusability and ethical concerns.
Therefore, to overcome the limitations of the previous endoscopic hemostasis simulators, we developed a new simulator using 3-dimensional (3D) printing technology.
The study was approved by the Institutional Review Board of Asan Medical Center (IRB number: 2016–0302) and performed in accordance with the principles of the Declaration of Helsinki. Twenty-one endoscopists (10 experts and 11 beginners) were recruited to assess the validity of the simulator in June 2017 at Asan Medical Center, Seoul, Korea. The expert group members were staff with experience of more than 50,000 cases of screening endoscopy and 1,000 cases of hemostasis. Eleven beginner group members were first-year clinical fellows with experience of more than 800 cases of EGD and 200 cases of colonoscopy.
The new simulator comprises the main body of the upper GI tract, two hemostasis modules for hemoclipping and injection therapy, and a digital peristaltic pump (EMP-600A; EMS Tech, Yongin, Korea) for supplying artificial blood. The main body of the simulator was modified from previous 3D-printed training simulator for endoscopic biopsy in the stomach (this paper is scheduled to be published). The stereolithographic files of the hard part of the two hemostasis modules and the molds of the soft part were produced with the 3D modeling program, Netfabb professional version 5 (Netfabb GmbH, Lupburg, Germany), and printed with the stereolithography 3D printer, Form 2 (Formlabs Inc, Somerville, MA, USA). The soft part of the hemostasis modules has produced by molding shell technique using the soft silicone, Platsil Gel-10 (Polytek, Easton, PA, USA). After assembly of each part, the two modules were inserted into the two holes of the main body, one on the anterior wall side of the proximal body and the other on the anterior wall side of the antrum. The outer part of each module has two tubes connected to the pump (commercial infusion pump for patients) supplying the artificial blood (Fig. 1). Any conventional endoscopic equipment such as esophagogastroduodenoscopes, hemoclips, and injectors can be used in the new simulator. Our test of endoscopic hemostasis was conducted with a standard single channel endoscope (GIF-Q260J; Olympus Co. Ltd., Tokyo, Japan), hemoclip (QuickClip Pro; Olympus Co. Ltd), and injector (NM-400Y-0423; Olympus Co. Ltd). The simulator has designed and produced by an experienced endoscopist.
A hemoclipping module was designed for endoscopic hemo-clipping training. The hemoclipping module comprises 16 protruding parts (Fig. 2A). The protruding parts were sealed with a metal pin; removal of the metal pin allows artificial blood to pump in a manner similar to that of real blood from a vessel (Fig. 2B). When the hemoclip is properly positioned, the flow of artificial blood stops (Fig. 2C).
The injection module was designed for the injection of normal saline near the bleeding site. The inner part of the injection module has two stacked chambers and the outer part is made of methacrylic acid ester cured by photo initiator (Fig. 3A). The bleeding pore is connected to the inner chamber and the flow of artificial blood stops when about 2 to 4 mL of normal saline is injected into the outer chamber (Fig. 3B and C).
The primary outcome measure was suitability of the simulator for hemostasis training. The expert group assessed the suitability of the simulator for hemostasis training. Only expert group members were selected as evaluators to rule out as much subjectivity as possible. After testing the simulator, self-administered questionnaires were given to the participants to estimate the efficacy of the hemostasis simulator using a 7-point Likert scale, where 1 indicates poor and 7 indicates excellent. The questions covered the following topics: (1) Handling of simulator is similarity with actual case; (2) Simulator is reasonable for hemostasis training; (3) Working with the simulator will improves trainee’s skills; (4) Training with the simulator reduces the risk for patients; (5) I recommend that the simulator be used in hemostasis training. The secondary outcome measure was the procedure time for new hemostasis simulator.
Statistical analysis was performed using SPSS software, version 21 (IBM Corp., Armonk, NY, USA). Continuous variables are reported as medians with interquartile ranges and/or as means±standard deviations. Descriptive statistics were used to describe data, such as reusability and similarity.
All participants completed the hemoclipping and injection methods successfully. There were no malfunctions during the test.
The 10 experts estimated the realism level of the new hemo-stasis simulator using a 7-point Likert scale (Table 1). The mean score of the hemoclipping module was 6.3±0.5 and the that of the injection module was 6.0±0.6. Participants strongly agreed that endoscopic handling in the simulator was realistic and reasonable for endoscopic training. Notably, all of the participants felt that this training could reduce the risk for patients.
Each group tested the hemostasis simulator. To compare the learning effect of the hemostasis simulator, the procedure times of each group were measured five times. Procedure time sharply decreased after each trial in the beginner group (Fig. 4). The mean procedure time per bleeding hole with hemoclipping module was 72.7±7.1 seconds for beginner group and 19.7±1.2 seconds for expert group (Table 2). The number of clips used for the hemostasis was 1 per person. The mean procedure time for the injection module was 92.1±9.8 seconds for beginner group and 36.3±2 seconds for expert group. The material used for the injection was a mean 4±1 mL of normal saline.
We developed a new endoscopic hemostasis simulator for hemoclipping and injection. The simulator is fully compatible with conventional endoscopic equipment and can be made from a 3D printer and basic materials. Ten experts evaluated the new simulator and agreed that it is effective for training. The approximate price of the simulator is $200, and the price may become lower depending on the production quantity. Because of the low cost and compatibility, endoscopists in hospitals without sufficient experience can easily receive training, which should significantly improve patient safety.
We assessed the efficacy and realism of a novel 3D endoscopic hemostasis simulator, with differing levels of experience. Procedure time became shorter as the participants repeated the training sessions. The expert group strongly agreed that this simulator was a useful tool for improving endoscopic hemostasis skills of trainee without any risks to patients.
Endoscopic hemostasis is a well-established procedure for the treatment of GI bleeding and effectively reduces morbidity and mortality.10 In previous studies, animal models have been used in training to simulate upper GI hemorrhage.8,9 However, this approach is not widely used due to problems with cost, usability, safety, ethics, and reusability.11 Because of ethical concerns, realistic
3D printing has been used in various fields of medicine. 3D-printed materials can be used to train various procedures, such as in orthopedics, spinal surgery, neurosurgery, and cardiac surgery.16,17 Recently, a simulator for endoscopic training and biopsy was developed and evaluated in our center.18,19 Because this first stomach biopsy simulator was made from a rectangular plastic box, it provides a different feeling compared with the actual stomach. Thus, a second stomach biopsy simulator was made with a 3D printer to have the same shape as the actual stomach. The second stomach biopsy simulator was found to be an effective and realistic method for improving biopsy skills without any risk to patients (unpublished data). Based on this new 3D printing technology and our experience, we created a new simulator for bleeding control to overcome the disadvantages of existing simulators.
This study had several limitations of note. First, gastric movement due to the heartbeat and respiration were not reproduced; thus, endoscopic hemostasis would have been easier than in a real patient. Second, there was a possible bias in evaluating the simulator using questionnaires. Third, the level of elasticity is different from real stomach. Nevertheless, our 3D-printed simulator has various benefits for endoscopic hemostasis training and could be the basis for a more complex simulator that overcomes the above drawbacks. Fourth, our simulator was not compared to other simulators and we could not include external expert groups for test. Therefore, there is possibility of subjectivity in the test for this simulator. To overcome this limitation, we tried to consist the evaluators as experts of our center.
In conclusion, the new simulator described herein has advantages over the previous hemostasis simulators due to improved realism, cost-effectiveness, and reusability. We believe that this new simulator could be applied to endoscopic hemostasis training in many centers and we have plans to improve it further by listening to user feedbacks and by including other hemostatic methods such as coagulation and argon plasma coagulation modules.
No potential conflict of interest relevant to this article was reported.
This study was supported by a grant (2016-7021) from the Asan Institute for Life Sciences, Asan Medical Center, Seoul, Korea.
Study concept and design, data acquisition, data analysis and interpretation, drafting of the manuscript: D.S.L. Critical revision of the manuscript for important intellectual content, obtained funding, administrative, technical, or material support, study supervision: G.H.L., J.Y.A.
Table 1 Mean Scores of the Answer to the Question for the Hemosta-sis Simulator Using a 7-Point Likert Scale
Index | Hemoclipping | Injection |
---|---|---|
Handling of simulator is similarity with actual case | 6.1±0.4 | 6.4±0.5 |
Simulator is reasonable for hemostasis training | 6.0±0.5 | 6.4±0.4 |
Working with the simulator will improves trainee’s skills | 6.3±0.5 | 6.7±0.5 |
Training with the simulator reduces the risk for patients | 6.1±0.7 | 6.9±0.5 |
I recommend that the simulator be used in hemostasis training | 6.1±0.7 | 6.9±0.5 |
Data are presented as the mean±SD. Scale, 1 (strongly disagree) to 7 (strongly agree).
Table 2 Procedure Completing Times with the New Hemostasis Simulator According to the Experience Level of the Endoscopist
Hemoclipping | Injection | |||
---|---|---|---|---|
Beginner group (n=11) | Expert group (n=10) | Beginner group (n=11) | Expert group (n=10) | |
1st trial | 116.1±15.3 | 25.1±1.2 | 161.3±13.4 | 46±3.1 |
2nd trial | 96.4±6.1 | 21.2±1.9 | 118.2±9.3 | 36.4±2 |
3rd trial | 65.8±3.3 | 18±1 | 77±10.7 | 33.6±1.6 |
4th trial | 54.8±6.9 | 17.7±1 | 61.1±8.2 | 32.9±2.2 |
5th trial | 30.5±4.1 | 16.6±1 | 43±7.2 | 32.4±1.5 |
Mean of 5 trials | 72.7±7.1 | 19.7±1.2 | 92.1±9.8 | 36.3±2 |
Data are presented as mean±SD. Time expressed in seconds.