Indexed In : Science Citation Index Expanded(SCIE), MEDLINE,
Pubmed/Pubmed Central, Elsevier Bibliographic, Google Scholar,
Databases(Scopus & Embase), KCI, KoreaMed, DOAJ
Gut and Liver is an international journal of gastroenterology, focusing on the gastrointestinal tract, liver, biliary tree, pancreas, motility, and neurogastroenterology. Gut atnd Liver delivers up-to-date, authoritative papers on both clinical and research-based topics in gastroenterology. The Journal publishes original articles, case reports, brief communications, letters to the editor and invited review articles in the field of gastroenterology. The Journal is operated by internationally renowned editorial boards and designed to provide a global opportunity to promote academic developments in the field of gastroenterology and hepatology. +MORE
Yong Chan Lee |
Professor of Medicine Director, Gastrointestinal Research Laboratory Veterans Affairs Medical Center, Univ. California San Francisco San Francisco, USA |
Jong Pil Im | Seoul National University College of Medicine, Seoul, Korea |
Robert S. Bresalier | University of Texas M. D. Anderson Cancer Center, Houston, USA |
Steven H. Itzkowitz | Mount Sinai Medical Center, NY, USA |
All papers submitted to Gut and Liver are reviewed by the editorial team before being sent out for an external peer review to rule out papers that have low priority, insufficient originality, scientific flaws, or the absence of a message of importance to the readers of the Journal. A decision about these papers will usually be made within two or three weeks.
The remaining articles are usually sent to two reviewers. It would be very helpful if you could suggest a selection of reviewers and include their contact details. We may not always use the reviewers you recommend, but suggesting reviewers will make our reviewer database much richer; in the end, everyone will benefit. We reserve the right to return manuscripts in which no reviewers are suggested.
The final responsibility for the decision to accept or reject lies with the editors. In many cases, papers may be rejected despite favorable reviews because of editorial policy or a lack of space. The editor retains the right to determine publication priorities, the style of the paper, and to request, if necessary, that the material submitted be shortened for publication.
Han Jo Jeon1 , Seung Jeong2,3 , Hyuk Soon Choi1 , Se Hyun Jang1 , Sang Hoon Kim1 , Seung Han Kim1 , Jae Min Lee1 , Eun Sun Kim1 , Bora Keum1 , Yoon Tae Jeen1 , Hong Sik Lee1 , Hoon Jai Chun1 , Jong Hoon Chung2 , Seong Nam Kim3
Correspondence to: Hyuk Soon Choi
ORCID https://orcid.org/0000-0002-4343-6950
E-mail mdkorea@gmail.com
Han Jo Jeon and Seung Jeong contributed equally to this work as first authors
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Gut Liver 2021;15(2):217-224. https://doi.org/10.5009/gnl19383
Published online May 13, 2020, Published date March 15, 2021
Copyright © Gut and Liver.
Background/Aims: Chitosan, a natural polymer widely used in the biomaterials field, has been proposed as a potential submucosal injection solution. The purpose of this study was to compare the performance and efficacy of aqueous chitosan solution and commercialized submucosal injection fluids using a three-dimensional sensor and to evaluate the efficacy of the measured parameters.
Methods: Normal saline (0.9% NaCl), as a control, Eleview® (Poloxamer 188), Blue EyeTM (0.4% hyaluronic acid), and aqueous chitosan solution (2.0%) were injected into the submucosa of porcine stomachs ex vivo. The mucosal elevation height, elevated surface area, and angle of the tangent of the submucosal fluid cushion were measured using a three-dimensional sensor. The rates of change for each variable were calculated, and the correlation between parameters was analyzed. Tissue specimens were stained with hematoxylin and eosin.
Results: All variables exhibited the highest values under chitosan injection. The mucosal elevation height rate of change differed significantly between normal saline and chitosan solution (p=0.024). The elevated surface area rates of change for normal saline and Eleview® were significantly different from those for TS-905 and chitosan solution (p=0.006 and p=0.009, respectively). Further, height, area, and angle showed a positive correlation (p<0.001). A histological examination revealed an even distribution of aqueous chitosan within the submucosa without tissue damage.
Conclusions: Aqueous chitosan was superior to normal saline and Eleview® and was noninferior to TS-905. A three-dimensional sensor and the measured parameters were effective and useful for evaluating the performance of submucosal fluids.
Keywords: Endoscopy, gastrointestinal, Chitosan, Stomach, Injections, Imaging, three-dimensional
Since the introduction of endoscopy for the diagnosis and treatment of gastrointestinal tract disease, therapeutic endoscopy has become a key tool for the removal of premalignant and malignant lesions.1 One of the most important techniques used during therapeutic endoscopy is the creation of a submucosal fluid cushion (SFC) via injection of a fluid into the submucosa, which elevates the mucosa of the lesion into a hemispherical shape. The SFC mechanically and thermally protects the muscularis propria and helps to prevent complications, such as thermal injury, bleeding, and perforation.2 At present, multiple submucosal injection fluids are available, and their advantages and disadvantages are widely contested.
Over the past 20 years, many studies have assessed the performance of various submucosal injection fluids.3-8 Among them, there are currently validated commercial products such as MucoUp® (0.4% hyaluronic acid) and Eleview® (Polaxamer 188), which were approved by the Food and Drug Administration in 2015. Nevertheless, several shortcomings of the available submucosal injection fluids reiterate the need to find effective, safe, and cost-saving submucosal solutions. Recently, several researchers have drawn attention to the potential of using photocrosslinkable chitosan (PCH) as a submucosal fluid.9- Notably, chitosan, the main component of PCH and the second most abundant biopolymer in nature, is a polysaccharide copolymer of glucosamine and N-acetyl glucosamine produced by the deacetylation of chitin. Chitosan is considered an innocuous substance, exerting hemostatic, antimicrobial, and antitumor effects, and has been shown to promote wound healing. Furthermore, chitosan itself is a highly viscous insoluble substance, which can be dissolved in an acidic solvent to form an aqueous solution. Given these advantageous properties, chitosan has been considered a strong candidate for use as a submucosal injection fluid. However, although current chitosan-associated research has focused on phase-change tests of PCH following exposure to ultraviolet (UV) radiation, there is a lack of data comparing chitosan with other solutions. In addition, PCH requires more preparation equipment and time before it can be applied to therapeutic endoscopy compared to the conventional method.
Therefore, we designed a simplified aqueous chitosan submucosal injection solution and hypothesized that it would create an elevated, convex SFC and would perform significantly better than clinically available submucosal injection fluids. Thus far, SFC studies have utilized rulers and photographic tools to assess the height of SFCs
The pigs used in the experiment were female hybrids with a bodyweight of 40 kg. All animals were quarantined for one week prior to the start of the study and fasted the day before the experiment. The average temperature in the laboratory was 21.3°C, and the humidity was 57.6%. All experiments were approved by the Institutional Animal Care and Use Committee of Korea University and were performed under supervision in a licensed animal laboratory (IACUC approval number: KOREA-2018-0116).
Pigs were sacrificed via intravenous injection of KCl (2 mmol/kg), and the stomach was excised within 30 minutes after sacrifice. Only the stomach body was used, and the tissue was fixed on a 5×5 cm cork plate with pins. One milliliter of each solution was injected tangentially (at a 45° angle) into the stomach tissue using a 2.5 mL syringe with a 23-gauge needle at a rate of 0.5 mL/s. The experiment was repeated eight times, and all injections were performed by the same individual.
In total, four solutions were prepared for injection (Fig. 1A): normal saline (NS; JW Pharmaceutical Corporation, Seoul, Korea), a 0.9% solution of NaCl; Eleview® (Aries Pharmaceuticals Inc., San Diego, CA, USA), a low-viscosity emulsion fluid containing poloxamer 188, polyoxyl-15-hydroxystearate, medium-chain triglycerides, methylene blue, and sodium chloride in water; TS-905 (Blue EyeTM; The Standard Co. Ltd., Gunpo, Korea), a solution of 0.4% hyaluronic acid mixed with methylene blue; and a 2.0% aqueous chitosan solution (degree of deacetylation, 95%; molecular weight, 20–100 kDa; Heppe Medical Chitosan GmbH, Halle, Germany).
The viscosity, injection pressure, and pH of the solutions used in the experiments were measured (Table 1). The viscosity was measured at 100 rpm, 15 cP, and 25°C for 1 minute using an SC4-34 Spindle DV1 Viscometer (AMETEK Brookfield, Middleboro, MA, USA). The injection pressure was measured using a Push-Pull gauge, DS2-200N (IMADA Inc., Northbrook, IL, USA), and a Tensile Strength Tester (test speed 100 mm/min) with an injection needle, NM-200U-0423 (Olympus, Tokyo, Japan) at 25°C. pH was measured at 25°C using an Orion Star A215 (Thermo Fisher Scientific Inc., Waltham, MA, USA).
The 3D sensor, Gocator® 3110 (LMI Technologies, Inc., Burnaby, BC, Canada), was mounted on a flat desk in an animal laboratory and connected to a computer. The 3D sensor scanned the SFC with high resolution at a speed of 5 Hz, using a non-contact method (Fig. 1B). The images were captured every 5 minutes for 30 minutes and were analyzed using the Gocator Emulator, a stand-alone application. The captured two-dimensional image was converted into a 3D image to estimate the shape of the SFC (Fig. 1C).
Our primary endpoint was the efficacy of aqueous chitosan solution in comparison with other solutions using a 3D sensor. Three variables were estimated by the 3D scanner directly; mucosal elevation height (MEH), the conventional parameter, elevated surface area (ESA), and angle of the tangent (AOT), which are newly introduced. MEH was defined as the vertical distance between the bottom plane of the tissue and the peak of the SFC (Fig. 1D). ESA was defined as the ESA from the bottom of the tissue of the SFC (Fig. 1E). AOT was defined as the angle between the tangent line and the bottom plane (Fig. 1F). Moreover, the rate of change for each parameter was calculated and compared to consider differences over time for efficacy assessment. The rate of change was defined as the amount of change over 30 minutes from the initial injection point for each parameter. Secondary endpoint was to assess additional parameters measured by the 3D sensor, namely ESA and AOT. Correlation analysis was conducted to define how similar the newly introduced variables, ESA and AOT, tend to be with the conventionally used MEH.
To compare the submucosal tissue injury induced by the SFC, the stomach tissue was fixed in 10% formalin solution. After the tissue was embedded in paraffin, it was sliced into 5 µm-thick sections, mounted on a slide, and stained with hematoxylin and eosin.
The nonparametric Kruskal-Wallis method was used to compare the results generated after the injection with each one of the four solutions. A mixed model for repeated measurement was used to confirm the difference in the pattern of changes between the solutions over time. Additionally, the Dwass, Steel, and Critchlow-Fligner method was used for post-hoc analysis. The correlation coefficients were determined between the three variables. All analyses were performed in SAS 9.4 (The SAS Institute, Cary, NC, USA). All p-values lower than 0.05 were considered significant.
The plots of change over time for the MEH, ESA, and AOT are depicted in Fig. 2. Notably, the initial MEH, ESA, and AOT values were significantly higher for the chitosan solution, Eleview®, and TS-905, than for NS (MEH, p<0.001; ESA, p<0.001; AOT, p<0.001). Further, the initial values of MEH and ESA were not significantly different between the chitosan solution, TS-905, and Eleview®, while the initial AOT values were significantly higher for the chitosan solution than for Eleview® (p=0.040). However, as the experiment progressed, significant differences were observed between the solutions except for the NS. After 5 minutes, Eleview® began to differ significantly from the chitosan solution and TS-905 in terms of MEH (Eleview® vs chitosan, p=0.002; Eleview® vs TS-905, p=0.002), ESA (Eleview® vs chitosan, p<0.001; Eleview® vs TS-905, p<0.001), and AOT (Eleview® vs TS-905, p=0.012), and these differences were maintained for 25 minutes. During the experiments, there were no significant differences between the chitosan solution and TS-905 in terms of MEH, ESA, or AOT.
To evaluate the performance of each submucosal fluid, the rates of change for each solution over the first 30 minutes after injection were also compared (Supplementary Table 1). According to our data, the rates of change of MEH and ESA were significantly different between solutions (MEH, p=0.008; ESA, p<0.001), but the rate of change of AOT did not differ between treatments (p=0.073). Post-hoc analyses were then performed to determine which solutions exhibited the highest efficiency (Fig. 3). Accordingly, the MEH rate of change was significantly different between NS and chitosan solution (p=0.024), as was the ESA rate of change between NS and TS-905 (p=0.006) and NS and chitosan solution (p=0.006). Furthermore, there were significant differences in the ESA rate of change between Eleview® and TS-905 (p=0.009) and Eleview® and chitosan solution (p=0.009).
Potential associations between MEH, ESA and AOT were analyzed and confirmed. The Pearson correlation coefficients revealed statistical significance (p<0.001) at both 0 and 30 minutes after injection and demonstrated a strong positive correlation among the measured variables (Table 2).
Chitosan solution, TS-905, and Eleview®, all exhibited an even distribution within the submucosa. Tissue sections of the SFC showed no muscle damage. At ×400 magnification, the vessel appeared intact, and the mucosal and submucosal layers were separated from the margin, without damaging the surrounding tissue (Fig. 4).
Given the breadth of publications assessing and comparing the performance of submucosal injection fluids, several properties of these agents have been thoroughly described. First, the ideal submucosal fluid should be harmless, cost-effective, easily injected using a needle and readily available in nature.21 Second, the viscosity of the submucosal fluid correlates with the duration of elevation.22 These requirements were, therefore, considered while evaluating the efficacy of aqueous chitosan as a submucosal injection fluid.
Various solutions have been assessed as submucosal fluids, including solutions of methylcellulose,3 hyaluronic acid,4 dextrose,5 glycerol,7 and hydroxyethyl starch.8,23 TS-905 is a solution of 0.4% sodium hyaluronic acid certificated by European Communities recently for use as a submucosal solution. However, hyaluronic acid is relatively expensive ($49.50–128.00 per mL)2 and has ability to promote tumor cell growth.24 Conversely, newly emerged Eleview® contains mainly poloxamer 188 that has proved its effectiveness and safety for endoscopic mucosal resection and dissection.25 Although its price ($8.10 per mL) is lower than that of hyaluronic acid, it has the disadvantages of inducing smoke formation and impairment of visualization during endoscopic submucosal dissection.26
PCH is made in the form of an Az-CH-LA aqueous solution by adding an azide group (Az) and lactose moieties to insoluble chitosan. This aqueous chitosan is crosslinked by UV radiation, resulting in the conversion of the liquid phase into a chitosan hydrogel. Although the utility of PCH as a submucosal fluid has been documented, several issues remain unaddressed. Importantly, conversion of the solution into a hydrogel requires time and UV irradiation, which causes tissue inflammation, while its safety remains doubtful. Additionally, homogeneous UV irradiation is difficult to achieve.10 Therefore, aqueous chitosan use was explored because of the limitations of PCH. Aqueous chitosan solution is a water-soluble polymer obtained through the neutralization of liquid chitosan, by mixing sodium hydroxide with acetic acid. Moreover, aqueous chitosan, unlike PCH, does not require UV irradiation.
Through this study, interesting characteristics of MEH, ESA, and AOT were discovered across the different submucosal fluids. From baseline, significant differences emerged between NS and the other solutions and were maintained for 30 minutes. Significant differences were noted between Eleview® and both chitosan and TS-905 within 5 minutes, but not between chitosan and TS-905 during the entire experimental period. Furthermore, TS-905 and aqueous chitosan were the most viscous solutions, followed by Eleview® and NS. Therefore, aligning with viscosity studies, the solutions can be classified in terms of viscosity, i.e., high-viscosity, (chitosan, TS-905), low-viscosity (Eleview®), and solutions with little viscosity (NS). In this study, the injection pressure and viscosity were compared concurrently. As previously demonstrated, the higher the viscosity, the higher the injection pressure.27 Accordingly, chitosan and TS-905 had a similar injection pressure, greater than Eleview® (Table 1). Hence, it is likely that aqueous chitosan injection would be clinically convenient.
Interestingly, our study also revealed the time point at which the solutions began to differ. Specifically, the first 5 minutes were critical in determining the performance of the SFC. These differences may be attributed, in part, to the composition and state of the solution. Aqueous chitosan and TS-905 are natural polymer solutions, while Eleview® is an emulsified aqueous solution.
MEH, ESA, and AOT were suitable for reflecting absolute values at time points and showing the trends of change over time, but they did not reflect the total decrement compared to the initial values during the observation period. Thus, the rates of change were devised in the performance assessment. According to these results, chitosan was the only solution to exhibit significant differences in the MEH and ESA rates of change relative to NS. Conversely, the MEH and ESA rates of change were not significantly different between Eleview® and NS or between TS-905 and chitosan, indicating that the SFC sinks faster with NS and Eleview® than with chitosan and hyaluronic acid during the first 30 minutes. There was no significant difference in the AOT rate of change, probably due to the lack of experimental tissues. We assume that a larger cohort would allow the generation of significant results. Further, the Pearson correlation coefficient indicated positive correlations between parameters. Hence, the result proves that the better performing SFC provides a higher and wider cushion with a larger angle, supporting the use of ESA and AOT as measures of SFC performance.
Prior to this study, only the MEH of the SFC had been measured to evaluate the performance of submucosal fluids, typically using a digital camera.22,26,28 However, these methods are less accurate and efficient than the 3D sensor described above. The 3D scanner performed real-time high-speed measurements by scanning with a blue light-emitting diode (465 nm) and reconstructed the 3D image of the SFC, producing a high-resolution cross-section. The processed data are characterized by high accuracy, consistency, repeatability, and reproducibility, with an error of less than 50 μm. Hence, 3D scanning technology is considered compatible with tests associated with submucosal fluids and could be incorporated into future studies.
This study has several limitations. It should be noted that we did not include hypertonic saline solution. We regarded safety as an important inclusion criterion for the selected solutions. However, hypertonic saline can cause tissue damage; therefore, it was excluded from our study. Nevertheless, even with the use of hypertonic saline solution, the results would not have changed due to the similar characteristics of NS and hypertonic saline solution. In addition, our
In conclusion, we demonstrated the efficacy of aqueous chitosan solution as a possible submucosal product. MEH, AOT, and ESA were measured using a 3D sensor to evaluate the SFCs. Liquid chitosan led to a higher, steeper, and larger SFC than the other solutions. Consequently, aqueous chitosan solution is superior to Eleview® and NS and performs comparably to sodium hyaluronic acid. Furthermore, the measured parameters positively correlated and proved the efficacy of the 3D scanner.
This work was supported by grants from the National Research Foundation of Korea (NRF, No. 2017 R1C1B2006425) and Korea Technology and Information Promotion Agency for Small and Medium-sized Enterprises (No. S2588953). The funding sources were not involved in the study design, data collection and interpretation, or preparation of the final report.
S.J. and S.N.K. are employees of Standard Co., Ltd. No other potential conflict of interest relevant to this article was reported.
Conceptualization: H.S.C., H.J.J., S.J., S.N.K., J.H.C. Data curation: H.J.J., S.J. Formal analysis: S.H.J., Sang Hoon Kim, Seung Han Kim, J.M.L., E.S.K. Funding acquisition: H.S.C., H.J.C. Methodology: H.S.C., B.K., H.J.J. Project administration: H.S.C., H.J.C. Visualization: H.J.J., H.S.C., Y.T.J., H.S.L., H.J.C. Writing - original draft: H.J.J. Writing - review & editing: H.J.J., S.J., J.H.C., H.S.C., B.K., Y.T.J., H.S.L., H.J.C. Approval of final manuscript: all authors.
Physicochemical Characteristics of the Solutions Used for Submucosal Injection
Solution | pH | Viscosity, cP | Injection pressure, N |
---|---|---|---|
Normal saline | 6.08 | 0.80 | 5.25 |
Eleview® | 6.00 | 5.60 | 15.74 |
TS-905 | 6.93 | 8.40 | 20.70 |
Chitosan solution | 6.04 | 7.40 | 20.40 |
Pearson Correlation Coefficient (ρ) between Variables
Variable | Pearson correlation coefficient ρ | p-value |
---|---|---|
MEH-ESA | ||
0 min | 0.804 | <0.001 |
30 min | 0.927 | <0.001 |
MEH-AOT | ||
0 min | 0.809 | <0.001 |
30 min | 0.885 | <0.001 |
ESA-AOT | ||
0 min | 0.838 | <0.001 |
30 min | 0.900 | <0.001 |
MEH, mucosal elevation height; ESA, elevated surface area; AOT, angle of tangent.
Gut and Liver 2021; 15(2): 217-224
Published online March 15, 2021 https://doi.org/10.5009/gnl19383
Copyright © Gut and Liver.
Han Jo Jeon1 , Seung Jeong2,3 , Hyuk Soon Choi1 , Se Hyun Jang1 , Sang Hoon Kim1 , Seung Han Kim1 , Jae Min Lee1 , Eun Sun Kim1 , Bora Keum1 , Yoon Tae Jeen1 , Hong Sik Lee1 , Hoon Jai Chun1 , Jong Hoon Chung2 , Seong Nam Kim3
1Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, 2Department of Biosystems & Biomaterials Science and Engineering, Seoul National University College of Agriculture and Life Science, Seoul, and 3Medical Engineering Research Center, The Standard Co. Ltd., Gunpo, Korea
Correspondence to:Hyuk Soon Choi
ORCID https://orcid.org/0000-0002-4343-6950
E-mail mdkorea@gmail.com
Han Jo Jeon and Seung Jeong contributed equally to this work as first authors
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Background/Aims: Chitosan, a natural polymer widely used in the biomaterials field, has been proposed as a potential submucosal injection solution. The purpose of this study was to compare the performance and efficacy of aqueous chitosan solution and commercialized submucosal injection fluids using a three-dimensional sensor and to evaluate the efficacy of the measured parameters.
Methods: Normal saline (0.9% NaCl), as a control, Eleview® (Poloxamer 188), Blue EyeTM (0.4% hyaluronic acid), and aqueous chitosan solution (2.0%) were injected into the submucosa of porcine stomachs ex vivo. The mucosal elevation height, elevated surface area, and angle of the tangent of the submucosal fluid cushion were measured using a three-dimensional sensor. The rates of change for each variable were calculated, and the correlation between parameters was analyzed. Tissue specimens were stained with hematoxylin and eosin.
Results: All variables exhibited the highest values under chitosan injection. The mucosal elevation height rate of change differed significantly between normal saline and chitosan solution (p=0.024). The elevated surface area rates of change for normal saline and Eleview® were significantly different from those for TS-905 and chitosan solution (p=0.006 and p=0.009, respectively). Further, height, area, and angle showed a positive correlation (p<0.001). A histological examination revealed an even distribution of aqueous chitosan within the submucosa without tissue damage.
Conclusions: Aqueous chitosan was superior to normal saline and Eleview® and was noninferior to TS-905. A three-dimensional sensor and the measured parameters were effective and useful for evaluating the performance of submucosal fluids.
Keywords: Endoscopy, gastrointestinal, Chitosan, Stomach, Injections, Imaging, three-dimensional
Since the introduction of endoscopy for the diagnosis and treatment of gastrointestinal tract disease, therapeutic endoscopy has become a key tool for the removal of premalignant and malignant lesions.1 One of the most important techniques used during therapeutic endoscopy is the creation of a submucosal fluid cushion (SFC) via injection of a fluid into the submucosa, which elevates the mucosa of the lesion into a hemispherical shape. The SFC mechanically and thermally protects the muscularis propria and helps to prevent complications, such as thermal injury, bleeding, and perforation.2 At present, multiple submucosal injection fluids are available, and their advantages and disadvantages are widely contested.
Over the past 20 years, many studies have assessed the performance of various submucosal injection fluids.3-8 Among them, there are currently validated commercial products such as MucoUp® (0.4% hyaluronic acid) and Eleview® (Polaxamer 188), which were approved by the Food and Drug Administration in 2015. Nevertheless, several shortcomings of the available submucosal injection fluids reiterate the need to find effective, safe, and cost-saving submucosal solutions. Recently, several researchers have drawn attention to the potential of using photocrosslinkable chitosan (PCH) as a submucosal fluid.9- Notably, chitosan, the main component of PCH and the second most abundant biopolymer in nature, is a polysaccharide copolymer of glucosamine and N-acetyl glucosamine produced by the deacetylation of chitin. Chitosan is considered an innocuous substance, exerting hemostatic, antimicrobial, and antitumor effects, and has been shown to promote wound healing. Furthermore, chitosan itself is a highly viscous insoluble substance, which can be dissolved in an acidic solvent to form an aqueous solution. Given these advantageous properties, chitosan has been considered a strong candidate for use as a submucosal injection fluid. However, although current chitosan-associated research has focused on phase-change tests of PCH following exposure to ultraviolet (UV) radiation, there is a lack of data comparing chitosan with other solutions. In addition, PCH requires more preparation equipment and time before it can be applied to therapeutic endoscopy compared to the conventional method.
Therefore, we designed a simplified aqueous chitosan submucosal injection solution and hypothesized that it would create an elevated, convex SFC and would perform significantly better than clinically available submucosal injection fluids. Thus far, SFC studies have utilized rulers and photographic tools to assess the height of SFCs
The pigs used in the experiment were female hybrids with a bodyweight of 40 kg. All animals were quarantined for one week prior to the start of the study and fasted the day before the experiment. The average temperature in the laboratory was 21.3°C, and the humidity was 57.6%. All experiments were approved by the Institutional Animal Care and Use Committee of Korea University and were performed under supervision in a licensed animal laboratory (IACUC approval number: KOREA-2018-0116).
Pigs were sacrificed via intravenous injection of KCl (2 mmol/kg), and the stomach was excised within 30 minutes after sacrifice. Only the stomach body was used, and the tissue was fixed on a 5×5 cm cork plate with pins. One milliliter of each solution was injected tangentially (at a 45° angle) into the stomach tissue using a 2.5 mL syringe with a 23-gauge needle at a rate of 0.5 mL/s. The experiment was repeated eight times, and all injections were performed by the same individual.
In total, four solutions were prepared for injection (Fig. 1A): normal saline (NS; JW Pharmaceutical Corporation, Seoul, Korea), a 0.9% solution of NaCl; Eleview® (Aries Pharmaceuticals Inc., San Diego, CA, USA), a low-viscosity emulsion fluid containing poloxamer 188, polyoxyl-15-hydroxystearate, medium-chain triglycerides, methylene blue, and sodium chloride in water; TS-905 (Blue EyeTM; The Standard Co. Ltd., Gunpo, Korea), a solution of 0.4% hyaluronic acid mixed with methylene blue; and a 2.0% aqueous chitosan solution (degree of deacetylation, 95%; molecular weight, 20–100 kDa; Heppe Medical Chitosan GmbH, Halle, Germany).
The viscosity, injection pressure, and pH of the solutions used in the experiments were measured (Table 1). The viscosity was measured at 100 rpm, 15 cP, and 25°C for 1 minute using an SC4-34 Spindle DV1 Viscometer (AMETEK Brookfield, Middleboro, MA, USA). The injection pressure was measured using a Push-Pull gauge, DS2-200N (IMADA Inc., Northbrook, IL, USA), and a Tensile Strength Tester (test speed 100 mm/min) with an injection needle, NM-200U-0423 (Olympus, Tokyo, Japan) at 25°C. pH was measured at 25°C using an Orion Star A215 (Thermo Fisher Scientific Inc., Waltham, MA, USA).
The 3D sensor, Gocator® 3110 (LMI Technologies, Inc., Burnaby, BC, Canada), was mounted on a flat desk in an animal laboratory and connected to a computer. The 3D sensor scanned the SFC with high resolution at a speed of 5 Hz, using a non-contact method (Fig. 1B). The images were captured every 5 minutes for 30 minutes and were analyzed using the Gocator Emulator, a stand-alone application. The captured two-dimensional image was converted into a 3D image to estimate the shape of the SFC (Fig. 1C).
Our primary endpoint was the efficacy of aqueous chitosan solution in comparison with other solutions using a 3D sensor. Three variables were estimated by the 3D scanner directly; mucosal elevation height (MEH), the conventional parameter, elevated surface area (ESA), and angle of the tangent (AOT), which are newly introduced. MEH was defined as the vertical distance between the bottom plane of the tissue and the peak of the SFC (Fig. 1D). ESA was defined as the ESA from the bottom of the tissue of the SFC (Fig. 1E). AOT was defined as the angle between the tangent line and the bottom plane (Fig. 1F). Moreover, the rate of change for each parameter was calculated and compared to consider differences over time for efficacy assessment. The rate of change was defined as the amount of change over 30 minutes from the initial injection point for each parameter. Secondary endpoint was to assess additional parameters measured by the 3D sensor, namely ESA and AOT. Correlation analysis was conducted to define how similar the newly introduced variables, ESA and AOT, tend to be with the conventionally used MEH.
To compare the submucosal tissue injury induced by the SFC, the stomach tissue was fixed in 10% formalin solution. After the tissue was embedded in paraffin, it was sliced into 5 µm-thick sections, mounted on a slide, and stained with hematoxylin and eosin.
The nonparametric Kruskal-Wallis method was used to compare the results generated after the injection with each one of the four solutions. A mixed model for repeated measurement was used to confirm the difference in the pattern of changes between the solutions over time. Additionally, the Dwass, Steel, and Critchlow-Fligner method was used for post-hoc analysis. The correlation coefficients were determined between the three variables. All analyses were performed in SAS 9.4 (The SAS Institute, Cary, NC, USA). All p-values lower than 0.05 were considered significant.
The plots of change over time for the MEH, ESA, and AOT are depicted in Fig. 2. Notably, the initial MEH, ESA, and AOT values were significantly higher for the chitosan solution, Eleview®, and TS-905, than for NS (MEH, p<0.001; ESA, p<0.001; AOT, p<0.001). Further, the initial values of MEH and ESA were not significantly different between the chitosan solution, TS-905, and Eleview®, while the initial AOT values were significantly higher for the chitosan solution than for Eleview® (p=0.040). However, as the experiment progressed, significant differences were observed between the solutions except for the NS. After 5 minutes, Eleview® began to differ significantly from the chitosan solution and TS-905 in terms of MEH (Eleview® vs chitosan, p=0.002; Eleview® vs TS-905, p=0.002), ESA (Eleview® vs chitosan, p<0.001; Eleview® vs TS-905, p<0.001), and AOT (Eleview® vs TS-905, p=0.012), and these differences were maintained for 25 minutes. During the experiments, there were no significant differences between the chitosan solution and TS-905 in terms of MEH, ESA, or AOT.
To evaluate the performance of each submucosal fluid, the rates of change for each solution over the first 30 minutes after injection were also compared (Supplementary Table 1). According to our data, the rates of change of MEH and ESA were significantly different between solutions (MEH, p=0.008; ESA, p<0.001), but the rate of change of AOT did not differ between treatments (p=0.073). Post-hoc analyses were then performed to determine which solutions exhibited the highest efficiency (Fig. 3). Accordingly, the MEH rate of change was significantly different between NS and chitosan solution (p=0.024), as was the ESA rate of change between NS and TS-905 (p=0.006) and NS and chitosan solution (p=0.006). Furthermore, there were significant differences in the ESA rate of change between Eleview® and TS-905 (p=0.009) and Eleview® and chitosan solution (p=0.009).
Potential associations between MEH, ESA and AOT were analyzed and confirmed. The Pearson correlation coefficients revealed statistical significance (p<0.001) at both 0 and 30 minutes after injection and demonstrated a strong positive correlation among the measured variables (Table 2).
Chitosan solution, TS-905, and Eleview®, all exhibited an even distribution within the submucosa. Tissue sections of the SFC showed no muscle damage. At ×400 magnification, the vessel appeared intact, and the mucosal and submucosal layers were separated from the margin, without damaging the surrounding tissue (Fig. 4).
Given the breadth of publications assessing and comparing the performance of submucosal injection fluids, several properties of these agents have been thoroughly described. First, the ideal submucosal fluid should be harmless, cost-effective, easily injected using a needle and readily available in nature.21 Second, the viscosity of the submucosal fluid correlates with the duration of elevation.22 These requirements were, therefore, considered while evaluating the efficacy of aqueous chitosan as a submucosal injection fluid.
Various solutions have been assessed as submucosal fluids, including solutions of methylcellulose,3 hyaluronic acid,4 dextrose,5 glycerol,7 and hydroxyethyl starch.8,23 TS-905 is a solution of 0.4% sodium hyaluronic acid certificated by European Communities recently for use as a submucosal solution. However, hyaluronic acid is relatively expensive ($49.50–128.00 per mL)2 and has ability to promote tumor cell growth.24 Conversely, newly emerged Eleview® contains mainly poloxamer 188 that has proved its effectiveness and safety for endoscopic mucosal resection and dissection.25 Although its price ($8.10 per mL) is lower than that of hyaluronic acid, it has the disadvantages of inducing smoke formation and impairment of visualization during endoscopic submucosal dissection.26
PCH is made in the form of an Az-CH-LA aqueous solution by adding an azide group (Az) and lactose moieties to insoluble chitosan. This aqueous chitosan is crosslinked by UV radiation, resulting in the conversion of the liquid phase into a chitosan hydrogel. Although the utility of PCH as a submucosal fluid has been documented, several issues remain unaddressed. Importantly, conversion of the solution into a hydrogel requires time and UV irradiation, which causes tissue inflammation, while its safety remains doubtful. Additionally, homogeneous UV irradiation is difficult to achieve.10 Therefore, aqueous chitosan use was explored because of the limitations of PCH. Aqueous chitosan solution is a water-soluble polymer obtained through the neutralization of liquid chitosan, by mixing sodium hydroxide with acetic acid. Moreover, aqueous chitosan, unlike PCH, does not require UV irradiation.
Through this study, interesting characteristics of MEH, ESA, and AOT were discovered across the different submucosal fluids. From baseline, significant differences emerged between NS and the other solutions and were maintained for 30 minutes. Significant differences were noted between Eleview® and both chitosan and TS-905 within 5 minutes, but not between chitosan and TS-905 during the entire experimental period. Furthermore, TS-905 and aqueous chitosan were the most viscous solutions, followed by Eleview® and NS. Therefore, aligning with viscosity studies, the solutions can be classified in terms of viscosity, i.e., high-viscosity, (chitosan, TS-905), low-viscosity (Eleview®), and solutions with little viscosity (NS). In this study, the injection pressure and viscosity were compared concurrently. As previously demonstrated, the higher the viscosity, the higher the injection pressure.27 Accordingly, chitosan and TS-905 had a similar injection pressure, greater than Eleview® (Table 1). Hence, it is likely that aqueous chitosan injection would be clinically convenient.
Interestingly, our study also revealed the time point at which the solutions began to differ. Specifically, the first 5 minutes were critical in determining the performance of the SFC. These differences may be attributed, in part, to the composition and state of the solution. Aqueous chitosan and TS-905 are natural polymer solutions, while Eleview® is an emulsified aqueous solution.
MEH, ESA, and AOT were suitable for reflecting absolute values at time points and showing the trends of change over time, but they did not reflect the total decrement compared to the initial values during the observation period. Thus, the rates of change were devised in the performance assessment. According to these results, chitosan was the only solution to exhibit significant differences in the MEH and ESA rates of change relative to NS. Conversely, the MEH and ESA rates of change were not significantly different between Eleview® and NS or between TS-905 and chitosan, indicating that the SFC sinks faster with NS and Eleview® than with chitosan and hyaluronic acid during the first 30 minutes. There was no significant difference in the AOT rate of change, probably due to the lack of experimental tissues. We assume that a larger cohort would allow the generation of significant results. Further, the Pearson correlation coefficient indicated positive correlations between parameters. Hence, the result proves that the better performing SFC provides a higher and wider cushion with a larger angle, supporting the use of ESA and AOT as measures of SFC performance.
Prior to this study, only the MEH of the SFC had been measured to evaluate the performance of submucosal fluids, typically using a digital camera.22,26,28 However, these methods are less accurate and efficient than the 3D sensor described above. The 3D scanner performed real-time high-speed measurements by scanning with a blue light-emitting diode (465 nm) and reconstructed the 3D image of the SFC, producing a high-resolution cross-section. The processed data are characterized by high accuracy, consistency, repeatability, and reproducibility, with an error of less than 50 μm. Hence, 3D scanning technology is considered compatible with tests associated with submucosal fluids and could be incorporated into future studies.
This study has several limitations. It should be noted that we did not include hypertonic saline solution. We regarded safety as an important inclusion criterion for the selected solutions. However, hypertonic saline can cause tissue damage; therefore, it was excluded from our study. Nevertheless, even with the use of hypertonic saline solution, the results would not have changed due to the similar characteristics of NS and hypertonic saline solution. In addition, our
In conclusion, we demonstrated the efficacy of aqueous chitosan solution as a possible submucosal product. MEH, AOT, and ESA were measured using a 3D sensor to evaluate the SFCs. Liquid chitosan led to a higher, steeper, and larger SFC than the other solutions. Consequently, aqueous chitosan solution is superior to Eleview® and NS and performs comparably to sodium hyaluronic acid. Furthermore, the measured parameters positively correlated and proved the efficacy of the 3D scanner.
This work was supported by grants from the National Research Foundation of Korea (NRF, No. 2017 R1C1B2006425) and Korea Technology and Information Promotion Agency for Small and Medium-sized Enterprises (No. S2588953). The funding sources were not involved in the study design, data collection and interpretation, or preparation of the final report.
S.J. and S.N.K. are employees of Standard Co., Ltd. No other potential conflict of interest relevant to this article was reported.
Conceptualization: H.S.C., H.J.J., S.J., S.N.K., J.H.C. Data curation: H.J.J., S.J. Formal analysis: S.H.J., Sang Hoon Kim, Seung Han Kim, J.M.L., E.S.K. Funding acquisition: H.S.C., H.J.C. Methodology: H.S.C., B.K., H.J.J. Project administration: H.S.C., H.J.C. Visualization: H.J.J., H.S.C., Y.T.J., H.S.L., H.J.C. Writing - original draft: H.J.J. Writing - review & editing: H.J.J., S.J., J.H.C., H.S.C., B.K., Y.T.J., H.S.L., H.J.C. Approval of final manuscript: all authors.
Table 1 Physicochemical Characteristics of the Solutions Used for Submucosal Injection
Solution | pH | Viscosity, cP | Injection pressure, N |
---|---|---|---|
Normal saline | 6.08 | 0.80 | 5.25 |
Eleview® | 6.00 | 5.60 | 15.74 |
TS-905 | 6.93 | 8.40 | 20.70 |
Chitosan solution | 6.04 | 7.40 | 20.40 |
Table 2 Pearson Correlation Coefficient (ρ) between Variables
Variable | Pearson correlation coefficient ρ | p-value |
---|---|---|
MEH-ESA | ||
0 min | 0.804 | <0.001 |
30 min | 0.927 | <0.001 |
MEH-AOT | ||
0 min | 0.809 | <0.001 |
30 min | 0.885 | <0.001 |
ESA-AOT | ||
0 min | 0.838 | <0.001 |
30 min | 0.900 | <0.001 |
MEH, mucosal elevation height; ESA, elevated surface area; AOT, angle of tangent.