Article Search
검색
검색 팝업 닫기

Metrics

Help

  • 1. Aims and Scope

    Gut and Liver is an international journal of gastroenterology, focusing on the gastrointestinal tract, liver, biliary tree, pancreas, motility, and neurogastroenterology. Gut atnd Liver delivers up-to-date, authoritative papers on both clinical and research-based topics in gastroenterology. The Journal publishes original articles, case reports, brief communications, letters to the editor and invited review articles in the field of gastroenterology. The Journal is operated by internationally renowned editorial boards and designed to provide a global opportunity to promote academic developments in the field of gastroenterology and hepatology. +MORE

  • 2. Editorial Board

    Editor-in-Chief + MORE

    Editor-in-Chief
    Yong Chan Lee Professor of Medicine
    Director, Gastrointestinal Research Laboratory
    Veterans Affairs Medical Center, Univ. California San Francisco
    San Francisco, USA

    Deputy Editor

    Deputy Editor
    Jong Pil Im Seoul National University College of Medicine, Seoul, Korea
    Robert S. Bresalier University of Texas M. D. Anderson Cancer Center, Houston, USA
    Steven H. Itzkowitz Mount Sinai Medical Center, NY, USA
  • 3. Editorial Office
  • 4. Articles
  • 5. Instructions for Authors
  • 6. File Download (PDF version)
  • 7. Ethical Standards
  • 8. Peer Review

    All papers submitted to Gut and Liver are reviewed by the editorial team before being sent out for an external peer review to rule out papers that have low priority, insufficient originality, scientific flaws, or the absence of a message of importance to the readers of the Journal. A decision about these papers will usually be made within two or three weeks.
    The remaining articles are usually sent to two reviewers. It would be very helpful if you could suggest a selection of reviewers and include their contact details. We may not always use the reviewers you recommend, but suggesting reviewers will make our reviewer database much richer; in the end, everyone will benefit. We reserve the right to return manuscripts in which no reviewers are suggested.

    The final responsibility for the decision to accept or reject lies with the editors. In many cases, papers may be rejected despite favorable reviews because of editorial policy or a lack of space. The editor retains the right to determine publication priorities, the style of the paper, and to request, if necessary, that the material submitted be shortened for publication.

Search

Search

Year

to

Article Type

Original Article

Split Viewer

Effectiveness of Capsule Endoscopy Compared with Other Diagnostic Modalities in Patients with Small Bowel Crohn’s Disease: A Meta-Analysis

Miyoung Choi1, Sungwon Lim1, Myung-Gyu Choi2, Ki-Nam Shim3, Seon Heui Lee4

1National Evidence-based Healthcare Collaborating Agency, The Catholic University of Korea College of Medicine, Seoul, Korea, 2Department of Internal Medicine, The Catholic University of Korea College of Medicine, Seoul, Korea, 3Department of Internal Medicine, Ewha Womans University School of Medicine, Seoul, Korea, 4Department of Nursing Science, College of Nursing, Gachon University, Incheon, Korea

Correspondence to: Ki-Nam Shima and Seon Heui Leeb. aDepartment of Internal Medicine, Ewha Womans University School of Medicine, 1071 Anyangcheon-ro, Yangcheon-gu, Seoul 07985, Korea, Tel: +82-2-2650-2632, Fax: +82-2-2655-2076, E-mail: shimkn@ewha.ac.kr. bDepartment of Nursing Science, College of Nursing, Gachon University, 191 Hambangmoe-ro, Yeonsu-gu, Incheon 21936, Korea, Tel: +82-32-820-4235, Fax: +82-32-820-4201, E-mail: sunarea87@gachon.ac.kr

Received: January 3, 2016; Revised: March 2, 2016; Accepted: May 10, 2016

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Gut Liver 2017;11(1):62-72. https://doi.org/10.5009/gnl16015

Published online October 13, 2016, Published date January 15, 2017

Copyright © Gut and Liver.

Background/Aims

As a result of the rapid development of medical diagnostic tools, physicians require concrete evidence to evaluate the effectiveness of the tools. We aimed to investigate the effectiveness and additional diagnostic benefits of capsule endoscopy (CE) in patients with small bowel Crohn’s disease (CD).

Methods

We performed a systematic search of databases, including MEDLINE, EMBASE, and the Cochrane Library, as well as eight domestic databases. Two reviewers independently screened all references. Diagnostic data from the studies were collected, and a meta-analysis was performed.

Results

Twenty-four studies were included. In cases of suspected CD, CE demonstrated a superior diagnostic yield compared with small bowel follow-through (SBFT) and enteroclysis (EC); however, there was no difference compared with computed tomography enterography or magnetic resonance enterography. In cases with established CD, CE demonstrated a higher diagnostic yield only compared with EC. In the detection of terminal ileum lesions, CE exhibited a significantly increased detection rate compared with ileoscopy.

Conclusions

The findings of our meta-analysis indicate that CE is superior to SBFT and EC in the evaluation of suspected CD cases. CE is also a more effective diagnostic modality in patients with established CD compared with EC.

Keywords: Capsule endoscopy, Diagnostic yield, Meta-analysis, Intestine, small, Crohn disease

Crohn’s disease (CD) is an inflammatory bowel disease that can affect the entire gastrointestinal tract, although the small bowel is the most commonly affected site.1 According to population-based epidemiologic studies, >50% of CD patients in Western countries24 and up to 77.0% to 87.7% of CD patients in Asian countries had small bowel involvement at diagnosis.5,6 Therefore, the evaluation of the small and large intestine is essential for the diagnosis of CD, although no pathognomonic features have been identified for endoscopic and radiologic studies. Such an evaluation is particularly vital in cases where ileoscopy is unsuccessful or where the distal ileum is not involved.

Small bowel radiography (e.g., small bowel follow-through [SBFT] and enteroclysis [EC]), colonoscopy with ileoscopy, and push enteroscopy (PE) are commonly available modalities for small bowel evaluation. Due to the limitations of each technique, it is difficult to adequately assess small bowel disease, particularly in cases with subtle mucosal changes or wherein the distal ileum is not involved. Considerable technological advancements, such as capsule endoscopy (CE), computed tomography enterography (CTE), and magnetic resonance enterography (MRE) have recently enabled a more accurate investigation of the small bowel.

Several previous meta-analyses have indicated that CE has superior diagnostic effectiveness, as compared to other modalities.7,8 Rapid technological advancements have been made in the era of CE and radiological evaluations, including CTE or MRE. In the present study, we aimed to evaluate the diagnostic yield of CE, compared with other diagnostic modalities, in patients with suspected and established CD, using previous and newly published studies.

1. Search strategy

A literature search was performed using core databases such as MEDLINE, EMBASE, and Cochrane Library, for all articles published up to March 2014. Moreover, eight domestic research databases were searched, including KoreaMed and KMBASE. Furthermore, manual searches were also performed. After reviewing previous related studies and abstracts, key clinical questions regarding the safety and effectiveness of CE, as well as the patient, intervention, comparators and outcomes (PICO) factors, were defined. The search terms were related to the intervention, and modified according to the index terms of each database, such as Medical Subject Heading (MeSH) and EMTREE. Extensive searches of the databases were performed using keywords such as “capsule endoscopy”, “VCE”, “SBCE”, and “WCE.”

2. Study selection criteria

Study selection was performed based on predefined inclusion/exclusion criteria. Studies that met the following criteria were included: (1) the study population included patients with small bowel CD; (2) the intervention was CE; (3) study design included randomized controlled trials, nonrandomized studies, and diagnostic studies; (4) modalities compared included PE, CTE, MRE, and EC; (5) one of the predetermined outcomes was reported; and (6) the language was English or Korean.

Studies on animals or preclinical studies, as well as articles other than original articles (e.g., reviews, editorials, letters, conference abstracts, and comments) were excluded. Articles not published in either English or Korean, and studies with duplicate subjects (i.e., different studies using the same outcome indicators in the same patient) were also excluded.

3. Outcomes

Diagnostic yield and diagnostic accuracy were the main outcome indicators of the effectiveness of CE. Patient satisfaction, therapeutic impact on further treatment, and additional diagnostic information gain in comparison to other modalities were considered as secondary outcomes. Capsule retention, incomplete diagnostic information, and other complications related to the CE procedure were investigated as safety outcomes.

4. A quality appraisal tool: Quality Assessment of Diagnostic Accuracy Studies-II

Determination of study design quality was performed using the Quality Assessment of Diagnostic Accuracy Studies-II (QUADAS-II) tool.9 QUADAS-II is a quality appraisal tool used in diagnostic studies. The four domains comprise patient selection, index test, reference standard, and flow and timing. The risk of bias and applicability of concerns were determined for individual studies, and were graded as “low,” “high,” or “unclear.” Some items were modified according to the PICO factors, such as in cases where the predefined threshold or cutoff was not applicable; in these cases, researchers did not evaluate these items.

There is no single reference standard for the diagnosis of suspected CD. After consulting a methodologist, the opinion of clinical experts or consensus among experts, based on all the available tests performed for suspected CD, was considered as a reference standard.

5. Data extraction and analysis

Using a pre-agreed data extraction format, two investigators independently extracted the data for review. The diagnostic yield, weighted incremental yield (IYw), and 95% confidence interval (CIs) were calculated.10 A random effect model was used to account for heterogeneity. However, in subgroup analysis, we used a fixed model for data that showed low heterogeneity. The extracted data were synthesized both quantitatively and qualitatively. A group of experts, comprising gastrointestinal clinicians and evidence-based medicine specialists, guided each stage. Statistical analysis was performed using Cochrane RevMan version 5.3 (The Nordic Cochrane Centre, The Cochrane Collaboration, 2014; RevMan, Copenhagen, Denmark).

1. Study characteristic and quality assessment

All the stages, from the literature search to the application of the selection criteria and data extraction, were independently performed by two researchers. A total of 7,498 studies were retrieved from the database. After exclusion of duplicates, 5,811 studies remained. Finally, 24 studies1134 were selected according to the selection and exclusion criteria (Fig. 1). The study characteristics are presented in Table 1. The findings of the quality assessment of all the included studies, using the QUADAS-II tool, are shown in Fig. 2. The “reference standard” domain showed a relatively low rate of “low risk of bias” as compared to the others.

2. Comparison of diagnostic yield

The diagnostic yield was reported in 19 studies. The data were analyzed according to the target population, including those with suspected or established CD.

In patients with suspected CD, CE was compared to SBFT, EC, CTE, and MRE (Fig. 3). A total four studies11,13,16,32 compared CE and SBFT, but one study32 was excluded in the meta-analysis because of high heterogeneity in the patient selection. The diagnostic yield of CE was statistically higher than that of SBFT (CE, 66.0% vs SBFT, 21.3%; IYw, 0.44; 95% CI, 0.29 to 0.59; I2, 30%). CE was compared with EC in two studies.14,28 CE showed a superior diagnostic yield as compared to EC (CE, 75.7% vs EC, 29.4%; IYw, 0.50; 95% CI, 0.21 to 0.79; I2, 52%). However, CE did not show a superior diagnostic yield as compared to CTE in two studies13,29 (CE, 72.5% vs CTE, 22.5%; IYw, 0.36; 95% CI, 0.18 to 0.90; I2, 68%). Moreover, CE did not show a significant superior diagnostic yield as compared to MRE in two studies (CE, 85.7% vs MRE, 100%; IYw, −0.16; 95% CI, −0.63 to 0.32; I2, 44%).20,27

In patients with established CD, CE only showed a statistically superior diagnostic yield as compared to EC group in four studies (CE, 68.5% vs EC, 36.7%; IYw, 0.39; 95% CI, 0.28 to 0.50; I2, 0%).14,15,17,28 The diagnostic yield of other modalities, such as SBFT, CTE, MRE, and IC, was not significantly different as compared to that of CE (Fig. 4).

3. Diagnostic accuracy

The reference standards varied in the included studies. Therefore, quantitative data was not synthesized for the calculation of diagnostic accuracy, although the sensitivity and specificity were calculated (Table 2).

In patients with suspected CD, two studies reported that the sensitivity and specificity of CE were 62% to 100% and 50% to 100%, whereas those for MRE were 77% and 80%, respectively.14,16 SBFT had the lowest sensitivity (27.6%) and 100% specificity.

In patients with established CD, the sensitivity and specificity of CE was found to be 77% to 100% and 53% to 100% in seven studies, respectively.14,17,19,22,25,31,33 The sensitivity and specificity of CTE were 76% to 82% and 85% to 89%, respectively, in two studies.25,31 Moreover, the sensitivity and specificity of MRE were 77% to 81% and 80% to 90%, respectively, in three studies.14,31,33

4. Detection of the terminal ileum lesion

In the detection of lesions in the terminal ileum in cases of established CD, the use of CE was compared to the use of ileocolonoscopy (IC) or CTE (Fig. 5) in five studies.18,19,22,24,31 The diagnostic yield of CE was statistically higher than that of IC (CE, 60% vs IC, 48%; IYw, 0.11; 95% CI, 0.00 to 0.22; I2, 55%). However, the diagnostic yield of CE was not superior to that of CTE (CE, 40% vs CTE, 32%; IYw, 0.08; 95% CI, −0.02 to 0.19; I2, 84%).

5. Additional diagnostic gain

A total four studies reported the additional lesions detected by CE. CE identified 40% (12/30) more lesions as compared to SBFT and small intestine contrast ultrasonography.32 Moreover, CE identified a mucosal lesion in six patients who showed normal results on SBFT.12 Furthermore, CE showed additional lesions that were not detected on MRE (9/52).26 With regard to the detection of recurrent lesions in the terminal ileum, CE showed two more lesions as compared to IC.19

The satisfaction of patients with CE, as compared to other modalities, has been reported in two studies. Patients preferred CE to MRE or balloon-assisted enteroscopy (2.73 vs 1.43 and 1.85, p<0.001) due to the lower burden of the examination in terms of discomfort during insertion, pain, and difficulty in swallowing.34 Moreover, CE was preferred to IC. Patients experienced greater discomfort during examination preparation and daily activities with IC (80%) than with CE (20%).24

6. Safety-related outcomes

A total of eight studies reported adverse events related to CE (Table 3).12,18,21,23,25,26,32,33 The most common adverse event included capsule retention (5.5%, 14 of 255 patients). Capsule malfunction was reported in one study (one of 28 patients), and abdominal pain was reported in one study. Incomplete examination results were reported in five studies (Table 4).14,15,17,21,28 However, incomplete examination results in CE were only noted in 7.5% patients (12 of 160 patients), as compared to those noted in other modalities (MRE, 12%; IC, 24%; and EC, 10.5%).

In the present study, we provided updated information from published relevant systematic reviews, and focused on the additional diagnostic gain with the use of CE in the clinical field. Similar previous meta-analyses focused on a comparison of the diagnostic yield; however, these studies included data from abstracts that were excluded in the present study as they yield inconsistent result.7,8,35 For a more precise comparison of diagnostic yield, we only included published studies, and divided the patients into cases with suspected and established CD. Moreover, a subgroup analysis was performed to identify the effectiveness of the diagnosis of terminal ileum lesions. Furthermore, we attempted to identify the additional diagnostic information or benefits in CD patients, including patient preference or satisfaction as well as adverse events.

Previous studies assumed that there would be different benefits for each patient group, and they indicated different results based on each patient group.7,8,35 In the present study, the diagnostic yield of CE was found to be superior to that of other modalities in several subgroup comparisons, although not all the comparisons showed consistency in effectiveness. In cases of suspected CD, CE showed a higher diagnostic yield as compared to SBFT and EC. As no reference standard has been established, it is difficult to identify lesions in asymptomatic patients; however, an advantage of CE is that it enables the visualization of the entire small bowel, and hence, small bowel lesions can be easily and directly detected.36 Our results may reflect this phenomenon. In contrast, in cases of established CD, CE showed a higher diagnostic yield as compared to EC; this has been also observed in previous studies.7,8 A previous meta-analysis on CE indicated that it had a higher diagnostic yield as compared to CTE in the cases with established disease and not in the cases with suspected disease.8 However, that study included abstracts and studies that were still in press. CD is frequently accompanied by extraluminal inflammation. In such cases, CTE and MRE may serve as more useful diagnostic modalities.37 Thus, our results reflect the strengths and limitations of CE.

In most patients with CD, the lesions are located in the terminal ileum, which can be accessed by IC.36 Previous meta-analyses did not report any comparisons of modalities based on the lesions of this area; however, we performed such a comparison in the subgroup analysis. With regard to the detection of the recurrence of terminal ileum lesions, CE has a more superior diagnostic yield than IC, but a comparable diagnostic yield with CTE. The small bowel beyond the duodenum and proximal to the terminal ileum is inaccessible in conventional endoscopy;36 therefore, CE would be a useful modality to examine terminal ileum lesions.

Although the included studies reported on the diagnostic accuracy, different reference standards have been used, as shown Table 1. SBFT and EC have been regarded as reference standard for radiographic assessment, but CTE and MRE are more accurate for the diagnosis of CD.36 In the present study, we could not determine whether CE had a superior diagnostic performance as compared to MRE or CTE. CD can be accompanied by extraluminal inflammation, and MRE and CTE are relatively novel and enhanced radiographic diagnostic methods that are more accurate for diagnosis as compared to SBFT or EC in such cases.36 Moreover, MRE is particularly useful for detecting transmural inflammation, stenosis, and extraintestinal lesions including abscesses and fistula.26,37 However, diagnostic effectiveness should not be judged based on diagnostic performance alone. The characteristics of CD such as systemic inflammation as well as recurrence are difficult to detect.37 CE shows the entire small bowel through the canal, and has a higher successful completion rate than other endoscopic modalities. One systematic review reported a pooled completion rate of CE of 84.4%, wherein single-arm studies were included.38

Moreover, patient preference and additional diagnostic gain should be considered in the clinical decision. Patient satisfaction was higher in the CE group, in terms of comfort during the procedure, as compared to other diagnostic methods. The most frequent adverse event related to CE was capsule retention. In the present study, the capsule retention rate was 5.4%. One systematic review reported a retention rate of 2.6%, although this review included single-arm studies, and hence included a large number of studies.38 A previous study of a large cohort reported a retention rate of 8.3% in CD.39 Capsule retention primarily occurs in cases of luminal stricture and stenosis.26 Therefore, in cases without stricture or stenosis of the bowel lumen, the use of CE is appropriate, as the retention rate would be acceptable.

This study has certain limitations. As the heterogeneity of the data was high, we performed subgroup analysis according to the patients and modalities. Therefore, the number of studies included in each subgroup analysis was too small to determine whether the effectiveness was significant. Moreover, there were differences in the reference standards and procedure settings, such as the interval of test timing and patient severity; this may also affect heterogeneity. In those studies used in this meta-analysis, as the patients of CD with known strictures which can be present in up to 25% of CD were excluded, the results have shown the yield of CE in a subgroup of patients with nonstricturing CD. If this population was included in the meta-analysis, the diagnostic yield of CTE and MRE would be higher. Other than that, the lack of a reference and/or gold standard may results in a confirmation bias, which may favor CE. CE found small bowel abnormality in about 20% of asymptomatic control patients,40 suggesting that many findings on CE maybe nonspecific and unrelated to the CD.

Our meta-analysis demonstrates that CE is superior to SBFT and EC in the evaluation of suspected CD. CE is also a more effective diagnostic modality in patients with established CD, as compared to EC. Moreover, other modalities such as CTE or MRE showed a similar diagnostic performance compared to CE. However, CE may be an effective diagnostic method to diagnose patients who do not show any abnormality in radiographic screening without the risk of stricture or stenosis. Moreover, CE can be more helpful in identifying terminal ileum lesions as compared to IC. In addition, patients appear to prefer CE over other modalities.

Larger prospective studies are needed to establish the role of CE for diagnosing suspected small bowel CD and evaluating established CD. As it is unknown whether these results will translate into improved patient outcomes or decrease health care expenditures with CE versus other modalities, randomized controlled trials will be necessary to answer these questions.

This study was funded by the National Evidence-based Healthcare Collaborating Agency (NECA), project number: NECA-C-14-008.

Fig. 1.Flow diagram of the study selection process.

DB, database; CD, Crohn’s disease.

Fig. 2.Quality assessments of the included studies. (A) Risk of bias graph. (B) Applicability concerns graph.
Fig. 3.Comparison of the diagnostic yield of different modalities for suspected Crohn’s disease. (A) Comparison of the diagnostic yields of CE and SBFT. (B) Comparison of the diagnostic yields of CE and EC. (C) Comparison of the diagnostic yields of CE and CTE. (D) Comparison of the diagnostic yields of CE and MRE.

CE, capsule endoscopy; SBFT, small bowel follow-through; IYw, weighted incremental yield; CI, confidence interval; EC, enteroclysis; CTE, computed tomography enterography; MRE, magnetic resonance enterography.

Fig. 4.Comparison of the diagnostic yield of different modalities for established Crohn’s disease. (A) Comparison of the diagnostic yields of CE and SBFT. (B) Comparison of the diagnostic yields of CE and EC. (C) Comparison of the diagnostic yields of CE and CTE. (D) Comparison of the diagnostic yields of CE and MRE. (E) Comparison of the diagnostic yields of CE and IC.

CE, capsule endoscopy; SBFT, small bowel follow-through; IYw, weighted incremental yield; CI, confidence interval; EC, enteroclysis; CTE, computed tomography enterography; MRE, magnetic resonance enterography; IC, ileocolonoscopy.

Fig. 5.Comparison of the diagnostic yield of different modalities for the detection of a terminal ileum lesion. (A) Comparison of the diagnostic yields of CE and IC. (B) Comparison of the diagnostic yields of CE and CTE.

CE, capsule endoscopy; IC, ileocolonoscopy; IYw, weighted incremental yield; CI, confidence interval; CTE, computed tomography enterography.

Characteristics of the Included Studies

Author (year)CountryPatients (N)Intervention (N)Comparators (N)Reference standard (N)Reported outcomes
Costamagna et al. (2002)11ItalySuspected small-bowel disease (20)CE (20)SBFT (22)Colonoscopy (20)Diagnostic yield
Buchman et al. (2004)12United StatesSuspected CD recurrence (30)CE (30)SBFT (30)Clinician opinion (30)Diagnostic yield
Correlation
Concordance
Additional diagnostic information
Patient satisfaction
Eliakim et al. (2004)13IsraelSuspected CD (35)CE (30)SBFT (35)IC and clinician opinion (35)Diagnostic yield
CTE (35)
IC (17)Patient satisfaction
Albert et al. (2005)14GermanySuspected and established CD (25)CE (14)MRI (25)All data including IC (52)Diagnostic accuracy
EC (24)
Chong et al. (2005)15AustraliaCrohn’s history (43)CE (43)PE (43)IC and expert consensus (43)Diagnostic yield
EC (43)Therapeutic impact
Dubcenco et al. (2005)16CanadaSuspected CD (39)CE (39)SBFT (39)IC (39)Diagnostic yield
Diagnostic accuracy
Marmo et al. (2005)17ItalyEstablished CD (31)CE (31)EC (31)Comprehensive decision (31)Diagnostic accuracy
Diagnostic yield
Voderholzer et al. (2005)18GermanyEstablished CD (56)CE (41)CTE (41)EGD or IC (56)Diagnostic yield
Therapeutic impact
Bourreille et al. (2006)19FranceOperated CD (32)CE (31)-IC (31)Diagnostic accuracy
Gölder et al. (2006)20GermanySuspected and established CD (17)CE (17)MRE (17)-Diagnostic yield
Hara et al. (2006)21United StatesSuspected and established CD (17)CE (17)CTE (17)IC (41)Diagnostic yield
SBFT (17)
Biancone et al. (2007)22ItalyEstablished and operated CD (22)CE (17)SBFT (22)IC (22)Diagnostic yield
Diagnostic accuracy
Park et al. (2007)23KoreaEstablished CD (52)CE (52)SBFT (52)Clinician opinion (52)Diagnostic yield
Concordance
Pons Beltrán et al. (2007)24SpainAfter operated CD (24)CE (22)IC (24)Clinician opinion (24)Diagnostic Yield
Patient Satisfaction
Therapeutic impact
Solem et al. (2008)25United StatesSuspected and established CD (41)CE (28)CTE (41)Expert consensus (41)Diagnostic accuracy
IC (36)
SBFT (38)
Tillack et al. (2008)26GermanyEstablished CD (19)CE (19)MRE (19)Comprehensive determination (19)Concordance
Additional diagnostic information
Crook et al. (2009)27SwitzerlandSuspected CD (5)CE (5)MRE (5)Clinical, histological, biomedical data comprehensive decision (5)Diagnostic accuracy
Diagnostic yield
Efthymiou et al. (2009)28GreeceSuspected or established CD (55)CE (55)EC (55)Expert consensus (55)Diagnostic yield
Rajesh et al. (2009)29United StatesSuspected CD (17)CE (5)CTE (5)Surgical and pathological gold standard data (17)Diagnostic yield
Böcker et al. (2010)30United StatesSuspected and established CD (21)CE (21)MRI (21)-Diagnostic yield
Jensen et al. (2011)31DenmarkSuspected or established CD (93)CE (87)MRE (89)IC, IC+surgery, surgery (75)Diagnostic accuracy
CTE (90)Diagnostic yield
Petruzziello et al. (2011)32ItalySuspected CD (30)CE (30)SBFT (30)Expert consensus (30)Concordance
SICUS (30)Diagnostic yield
IC (30)Additional diagnostic information
Wiarda et al. (2012)33NetherlandSuspected or established CD (38)CE (38)MRE (38)BAE+expert consensus (38)Diagnostic accuracy
Wiarda et al. (2013)34NetherlandSuspected CD (38)CE (59)MRE (76)-Patient preference
OGIB (38)BAE (76)Patient satisfaction

Diagnostic Accuracy

Author (year)Reference standard (N)PopulationSubgroupModalities (N)Sensitivity, %Specificity, %
Suspected CD
 Albert et al. (2005)14All clinical data including IC (52)Suspected CD-CE (25)92.0100.0
MRE (25)77.080.0
 Dubcenco et al. (2005)16IC (39)Suspected CD-CE (39)89.6100.0
SBFT (39)27.6100.0
Established CD
 Albert et al. (2005)14All data including IC (52)Established CD-CE (27)92.0100.0
MRE (27)77.080.0
 Marmo et al. (2005)17Comprehensive decision (31)Established CDEstablished terminal ileumCE (16)87.0-
EC (16)37.0-
 Bourreille et al. (2006)19Ileoscopy (32)Established CDLowerCE (31)62.090.0
Upper76.0100.0
LowerIC (31)86.050.0
Upper86.079.0
 Biancone et al. (2007)22IC (22)Established CDRecurrenceCE (22)100.0100.0
Terminal ileum recurCE (17)93.067.0
 Solem et al. (2008)25Expert consensus (41)Established CDCE (27)83.053.0
CTE (41)82.089.0
 Jensen et al. (2011)31IC, IC+surgery, surgery (75)Established CD-CE (87)100.091.0
MRE (89)81.086.0
CTE (90)76.085.0
 Wiarda et al. (2012)33BAE+expert consensus (38)Established CD-CE (38)57.188.9
MRE (38)76.789.5

Capsule-Related Adverse Events

Author (year)Capsule retention, % (n/N)Capsule malfunction, % (n/N)Cause (n)
Buchman et al. (2004)126.7 (2/30)-Small bowel stenosis (2)
Voderholzer et al. (2005)184.9 (2/41)-Terminal ileum inflammation (1), jejunal stenosis (1)
Hara et al. (2006)215.9 (1/17)-Small bowel stenosis (1)
Park et al. (2007)239.6 (5/52)-Small bowel stenosis (5)
Solem et al. (2008)25-3.6 (1/28)Technical failure (1)
Tillack et al. (2008)265.3 (1/19)-Site of stenosis
Petruzziello et al. (2011)323.3 (1/30)-Ulcerated stenosis (1)
Wiarda et al. (2012)332.6 (1/38)-Small bowel stenosis (1)

Incomplete Examination Rate and Causes

Author (year)Index testComparators


CE, % (n/N)Cause, % (n)MRE, % (n/N)IC, % (n/N)EC, % (n/N)Cause (n)
Albert et al. (2005)147.1 (1/14)Retention (1)12.0 (3/25)-8.3 (2/24)-
Chong et al. (2005)152.3 (1/43)Dysphagia (1)--13.9 (6/43)Tube insertion failure and denial (6)
Marmo et al. (2005)1725.8 (8/31)Cecum reach failure (2), low quality of result (6)--0 (0/31)-
Hara et al. (2006)2111.7 (2/17)--23.5 (4/17)--
Efthymiou et al. (2009)280 (0/55)---1.5 (8/55)Tube insertion failure (8)

  1. Baumgart, DC, and Sandborn, WJ (2012). Crohn’s disease. Lancet. 380, 1590-1605.
    Pubmed CrossRef
  2. Gower-Rousseau, C, Vasseur, F, and Fumery, M (2013). Epidemiology of inflammatory bowel diseases: new insights from a French population-based registry (EPIMAD). Dig Liver Dis. 45, 89-94.
    CrossRef
  3. Nuij, VJ, Zelinkova, Z, and Rijk, MC (2013). Phenotype of inflammatory bowel disease at diagnosis in the Netherlands: a population-based inception cohort study (the Delta Cohort). Inflamm Bowel Dis. 19, 2215-2222.
    Pubmed CrossRef
  4. Sjöberg, D, Holmström, T, and Larsson, M (2014). Incidence and clinical course of Crohn’s disease during the first year-results from the IBD Cohort of the Uppsala Region (ICURE) of Sweden 2005–2009. J Crohns Colitis. 8, 215-222.
    CrossRef
  5. Yang, SK, Yun, S, and Kim, JH (2008). Epidemiology of inflammatory bowel disease in the Songpa-Kangdong district, Seoul, Korea, 1986–2005: a KASID study. Inflamm Bowel Dis. 14, 542-549.
    CrossRef
  6. Abdul-Baki, H, ElHajj, I, and El-Zahabi, LM (2007). Clinical epidemiology of inflammatory bowel disease in Lebanon. Inflamm Bowel Dis. 13, 475-480.
    Pubmed CrossRef
  7. Triester, SL, Leighton, JA, and Leontiadis, GI (2006). A meta-analysis of the yield of capsule endoscopy compared to other diagnostic modalities in patients with non-stricturing small bowel Crohn’s disease. Am J Gastroenterol. 101, 954-964.
    Pubmed CrossRef
  8. Dionisio, PM, Gurudu, SR, and Leighton, JA (2010). Capsule endoscopy has a significantly higher diagnostic yield in patients with suspected and established small-bowel Crohn’s disease: a meta-analysis. Am J Gastroenterol. 105, 1240-1248.
    CrossRef
  9. Whiting, PF, Rutjes, AW, and Westwood, ME (2011). QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 155, 529-536.
    Pubmed CrossRef
  10. Higgins, JP, and Green, S (2008). Cochrane handbook for systematic reviews of interventions. Chichester: Wiley-Blackwell
    CrossRef
  11. Costamagna, G, Shah, SK, and Riccioni, ME (2002). A prospective trial comparing small bowel radiographs and video capsule endoscopy for suspected small bowel disease. Gastroenterology. 123, 999-1005.
    Pubmed CrossRef
  12. Buchman, AL, Miller, FH, Wallin, A, Chowdhry, AA, and Ahn, C (2004). Video-capsule endoscopy versus barium contrast studies for the diagnosis of Crohn’s disease recurrence involving the small intestine. Am J Gastroenterol. 99, 2171-2177.
    Pubmed CrossRef
  13. Eliakim, R, Suissa, A, Yassin, K, Katz, D, and Fischer, D (2004). Wireless capsule video endoscopy compared to barium follow-through and computerised tomography in patients with suspected Crohn’s disease: final report. Dig Liver Dis. 36, 519-522.
    Pubmed CrossRef
  14. Albert, JG, Martiny, F, and Krummenerl, A (2005). Diagnosis of small bowel Crohn’s disease: a prospective comparison of capsule endoscopy with magnetic resonance imaging and fluoroscopic enteroclysis. Gut. 54, 1721-1727.
    Pubmed KoreaMed CrossRef
  15. Chong, AK, Taylor, A, Miller, A, Hennessy, O, Connell, W, and Desmond, P (2005). Capsule endoscopy vs. push enteroscopy and enteroclysis in suspected small-bowel Crohn’s disease. Gastrointest Endosc. 61, 255-261.
    Pubmed CrossRef
  16. Dubcenco, E, Jeejeebhoy, KN, and Petroniene, R (2005). Capsule endoscopy findings in patients with established and suspected small-bowel Crohn’s disease: correlation with radiologic, endoscopic, and histologic findings. Gastrointest Endosc. 62, 538-544.
    Pubmed CrossRef
  17. Marmo, R, Rotondano, G, and Piscopo, R (2005). Capsule endoscopy versus enteroclysis in the detection of small-bowel involvement in Crohn’s disease: a prospective trial. Clin Gastroenterol Hepatol. 3, 772-776.
    Pubmed CrossRef
  18. Voderholzer, WA, Beinhoelzl, J, and Rogalla, P (2005). Small bowel involvement in Crohn’s disease: a prospective comparison of wireless capsule endoscopy and computed tomography enteroclysis. Gut. 54, 369-373.
    Pubmed KoreaMed CrossRef
  19. Bourreille, A, Jarry, M, and D’Halluin, PN (2006). Wireless capsule endoscopy versus ileocolonoscopy for the diagnosis of postoperative recurrence of Crohn’s disease: a prospective study. Gut. 55, 978-983.
    Pubmed KoreaMed CrossRef
  20. Gölder, SK, Schreyer, AG, and Endlicher, E (2006). Comparison of capsule endoscopy and magnetic resonance (MR) enteroclysis in suspected small bowel disease. Int J Colorectal Dis. 21, 97-104.
    CrossRef
  21. Hara, AK, Leighton, JA, and Heigh, RI (2006). Crohn disease of the small bowel: preliminary comparison among CT enterography, capsule endoscopy, small-bowel follow-through, and ileoscopy. Radiology. 238, 128-134.
    CrossRef
  22. Biancone, L, Calabrese, E, and Petruzziello, C (2007). Wireless capsule endoscopy and small intestine contrast ultrasonography in recurrence of Crohn’s disease. Inflamm Bowel Dis. 13, 1256-1265.
    Pubmed CrossRef
  23. Park, CH, Kim, JO, and Choi, MG (2007). Utility of capsule endoscopy for the classification of Crohn’s disease: a multicenter study in Korea. Dig Dis Sci. 52, 1405-1409.
    Pubmed CrossRef
  24. Pons Beltrán, V, Nos, P, and Bastida, G (2007). Evaluation of postsurgical recurrence in Crohn’s disease: a new indication for capsule endoscopy?. Gastrointest Endosc. 66, 533-540.
    CrossRef
  25. Solem, CA, Loftus, EV, and Fletcher, JG (2008). Small-bowel imaging in Crohn’s disease: a prospective, blinded, 4-way comparison trial. Gastrointest Endosc. 68, 255-266.
    Pubmed CrossRef
  26. Tillack, C, Seiderer, J, and Brand, S (2008). Correlation of magnetic resonance enteroclysis (MRE) and wireless capsule endoscopy (CE) in the diagnosis of small bowel lesions in Crohn’s disease. Inflamm Bowel Dis. 14, 1219-1228.
    Pubmed CrossRef
  27. Crook, DW, Knuesel, PR, and Froehlich, JM (2009). Comparison of magnetic resonance enterography and video capsule endoscopy in evaluating small bowel disease. Eur J Gastroenterol Hepatol. 21, 54-65.
    CrossRef
  28. Efthymiou, A, Viazis, N, and Vlachogiannakos, J (2009). Wireless capsule endoscopy versus enteroclysis in the diagnosis of small-bowel Crohn’s disease. Eur J Gastroenterol Hepatol. 21, 866-871.
    Pubmed CrossRef
  29. Rajesh, A, Sandrasegaran, K, and Jennings, SG (2009). Comparison of capsule endoscopy with enteroclysis in the investigation of small bowel disease. Abdom Imaging. 34, 459-466.
    CrossRef
  30. Böcker, U, Dinter, D, and Litterer, C (2010). Comparison of magnetic resonance imaging and video capsule enteroscopy in diagnosing small-bowel pathology: localization-dependent diagnostic yield. Scand J Gastroenterol. 45, 490-500.
    Pubmed CrossRef
  31. Jensen, MD, Nathan, T, Rafaelsen, SR, and Kjeldsen, J (2011). Diagnostic accuracy of capsule endoscopy for small bowel Crohn’s disease is superior to that of MR enterography or CT enterography. Clin Gastroenterol Hepatol. 9, 124-129.
    CrossRef
  32. Petruzziello, C, Calabrese, E, and Onali, S (2011). Small bowel capsule endoscopy vs conventional techniques in patients with symptoms highly compatible with Crohn’s disease. J Crohns Colitis. 5, 139-147.
    Pubmed CrossRef
  33. Wiarda, BM, Mensink, PB, and Heine, DG (2012). Small bowel Crohn’s disease: MR enteroclysis and capsule endoscopy compared to balloon-assisted enteroscopy. Abdom Imaging. 37, 397-403.
    CrossRef
  34. Wiarda, BM, Stolk, M, and Heine, DG (2013). Patient burden and patient preference: comparing magnetic resonance enteroclysis, capsule endoscopy and balloon-assisted enteroscopy. J Gastroenterol Hepatol. 28, 464-471.
    CrossRef
  35. Park, SK, Ye, BD, and Kim, KO (2015). Guidelines for video capsule endoscopy: emphasis on Crohn’s disease. Clin Endosc. 48, 128-135.
    Pubmed KoreaMed CrossRef
  36. Bourreille, A, Ignjatovic, A, and Aabakken, L (2009). Role of small-bowel endoscopy in the management of patients with inflammatory bowel disease: an international OMED-ECCO consensus. Endoscopy. 41, 618-637.
    Pubmed CrossRef
  37. Naganuma, M, Hosoe, N, Kanai, T, and Ogata, H (2015). Recent trends in diagnostic techniques for inflammatory bowel disease. Korean J Intern Med. 30, 271-278.
    Pubmed KoreaMed CrossRef
  38. Liao, Z, Gao, R, Xu, C, and Li, ZS (2010). Indications and detection, completion, and retention rates of small-bowel capsule endoscopy: a systematic review. Gastrointest Endosc. 71, 280-286.
    Pubmed CrossRef
  39. Cheon, JH, Kim, YS, and Lee, IS (2007). Can we predict spontaneous capsule passage after retention? A nationwide study to evaluate the incidence and clinical outcomes of capsule retention. Endoscopy. 39, 1046-1052.
    Pubmed CrossRef
  40. Goldstein, JL, Eisen, GM, and Lewis, B (2005). Video capsule endoscopy to prospectively assess small bowel injury with celecoxib, naproxen plus omeprazole, and placebo. Clin Gastroenterol Hepatol. 3, 133-141.
    Pubmed CrossRef

Article

Original Article

Gut and Liver 2017; 11(1): 62-72

Published online January 15, 2017 https://doi.org/10.5009/gnl16015

Copyright © Gut and Liver.

Effectiveness of Capsule Endoscopy Compared with Other Diagnostic Modalities in Patients with Small Bowel Crohn’s Disease: A Meta-Analysis

Miyoung Choi1, Sungwon Lim1, Myung-Gyu Choi2, Ki-Nam Shim3, Seon Heui Lee4

1National Evidence-based Healthcare Collaborating Agency, The Catholic University of Korea College of Medicine, Seoul, Korea, 2Department of Internal Medicine, The Catholic University of Korea College of Medicine, Seoul, Korea, 3Department of Internal Medicine, Ewha Womans University School of Medicine, Seoul, Korea, 4Department of Nursing Science, College of Nursing, Gachon University, Incheon, Korea

Correspondence to:Ki-Nam Shima and Seon Heui Leeb. aDepartment of Internal Medicine, Ewha Womans University School of Medicine, 1071 Anyangcheon-ro, Yangcheon-gu, Seoul 07985, Korea, Tel: +82-2-2650-2632, Fax: +82-2-2655-2076, E-mail: shimkn@ewha.ac.kr. bDepartment of Nursing Science, College of Nursing, Gachon University, 191 Hambangmoe-ro, Yeonsu-gu, Incheon 21936, Korea, Tel: +82-32-820-4235, Fax: +82-32-820-4201, E-mail: sunarea87@gachon.ac.kr

Received: January 3, 2016; Revised: March 2, 2016; Accepted: May 10, 2016

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

Background/Aims

As a result of the rapid development of medical diagnostic tools, physicians require concrete evidence to evaluate the effectiveness of the tools. We aimed to investigate the effectiveness and additional diagnostic benefits of capsule endoscopy (CE) in patients with small bowel Crohn’s disease (CD).

Methods

We performed a systematic search of databases, including MEDLINE, EMBASE, and the Cochrane Library, as well as eight domestic databases. Two reviewers independently screened all references. Diagnostic data from the studies were collected, and a meta-analysis was performed.

Results

Twenty-four studies were included. In cases of suspected CD, CE demonstrated a superior diagnostic yield compared with small bowel follow-through (SBFT) and enteroclysis (EC); however, there was no difference compared with computed tomography enterography or magnetic resonance enterography. In cases with established CD, CE demonstrated a higher diagnostic yield only compared with EC. In the detection of terminal ileum lesions, CE exhibited a significantly increased detection rate compared with ileoscopy.

Conclusions

The findings of our meta-analysis indicate that CE is superior to SBFT and EC in the evaluation of suspected CD cases. CE is also a more effective diagnostic modality in patients with established CD compared with EC.

Keywords: Capsule endoscopy, Diagnostic yield, Meta-analysis, Intestine, small, Crohn disease

INTRODUCTION

Crohn’s disease (CD) is an inflammatory bowel disease that can affect the entire gastrointestinal tract, although the small bowel is the most commonly affected site.1 According to population-based epidemiologic studies, >50% of CD patients in Western countries24 and up to 77.0% to 87.7% of CD patients in Asian countries had small bowel involvement at diagnosis.5,6 Therefore, the evaluation of the small and large intestine is essential for the diagnosis of CD, although no pathognomonic features have been identified for endoscopic and radiologic studies. Such an evaluation is particularly vital in cases where ileoscopy is unsuccessful or where the distal ileum is not involved.

Small bowel radiography (e.g., small bowel follow-through [SBFT] and enteroclysis [EC]), colonoscopy with ileoscopy, and push enteroscopy (PE) are commonly available modalities for small bowel evaluation. Due to the limitations of each technique, it is difficult to adequately assess small bowel disease, particularly in cases with subtle mucosal changes or wherein the distal ileum is not involved. Considerable technological advancements, such as capsule endoscopy (CE), computed tomography enterography (CTE), and magnetic resonance enterography (MRE) have recently enabled a more accurate investigation of the small bowel.

Several previous meta-analyses have indicated that CE has superior diagnostic effectiveness, as compared to other modalities.7,8 Rapid technological advancements have been made in the era of CE and radiological evaluations, including CTE or MRE. In the present study, we aimed to evaluate the diagnostic yield of CE, compared with other diagnostic modalities, in patients with suspected and established CD, using previous and newly published studies.

MATERIALS AND METHODS

1. Search strategy

A literature search was performed using core databases such as MEDLINE, EMBASE, and Cochrane Library, for all articles published up to March 2014. Moreover, eight domestic research databases were searched, including KoreaMed and KMBASE. Furthermore, manual searches were also performed. After reviewing previous related studies and abstracts, key clinical questions regarding the safety and effectiveness of CE, as well as the patient, intervention, comparators and outcomes (PICO) factors, were defined. The search terms were related to the intervention, and modified according to the index terms of each database, such as Medical Subject Heading (MeSH) and EMTREE. Extensive searches of the databases were performed using keywords such as “capsule endoscopy”, “VCE”, “SBCE”, and “WCE.”

2. Study selection criteria

Study selection was performed based on predefined inclusion/exclusion criteria. Studies that met the following criteria were included: (1) the study population included patients with small bowel CD; (2) the intervention was CE; (3) study design included randomized controlled trials, nonrandomized studies, and diagnostic studies; (4) modalities compared included PE, CTE, MRE, and EC; (5) one of the predetermined outcomes was reported; and (6) the language was English or Korean.

Studies on animals or preclinical studies, as well as articles other than original articles (e.g., reviews, editorials, letters, conference abstracts, and comments) were excluded. Articles not published in either English or Korean, and studies with duplicate subjects (i.e., different studies using the same outcome indicators in the same patient) were also excluded.

3. Outcomes

Diagnostic yield and diagnostic accuracy were the main outcome indicators of the effectiveness of CE. Patient satisfaction, therapeutic impact on further treatment, and additional diagnostic information gain in comparison to other modalities were considered as secondary outcomes. Capsule retention, incomplete diagnostic information, and other complications related to the CE procedure were investigated as safety outcomes.

4. A quality appraisal tool: Quality Assessment of Diagnostic Accuracy Studies-II

Determination of study design quality was performed using the Quality Assessment of Diagnostic Accuracy Studies-II (QUADAS-II) tool.9 QUADAS-II is a quality appraisal tool used in diagnostic studies. The four domains comprise patient selection, index test, reference standard, and flow and timing. The risk of bias and applicability of concerns were determined for individual studies, and were graded as “low,” “high,” or “unclear.” Some items were modified according to the PICO factors, such as in cases where the predefined threshold or cutoff was not applicable; in these cases, researchers did not evaluate these items.

There is no single reference standard for the diagnosis of suspected CD. After consulting a methodologist, the opinion of clinical experts or consensus among experts, based on all the available tests performed for suspected CD, was considered as a reference standard.

5. Data extraction and analysis

Using a pre-agreed data extraction format, two investigators independently extracted the data for review. The diagnostic yield, weighted incremental yield (IYw), and 95% confidence interval (CIs) were calculated.10 A random effect model was used to account for heterogeneity. However, in subgroup analysis, we used a fixed model for data that showed low heterogeneity. The extracted data were synthesized both quantitatively and qualitatively. A group of experts, comprising gastrointestinal clinicians and evidence-based medicine specialists, guided each stage. Statistical analysis was performed using Cochrane RevMan version 5.3 (The Nordic Cochrane Centre, The Cochrane Collaboration, 2014; RevMan, Copenhagen, Denmark).

RESULTS

1. Study characteristic and quality assessment

All the stages, from the literature search to the application of the selection criteria and data extraction, were independently performed by two researchers. A total of 7,498 studies were retrieved from the database. After exclusion of duplicates, 5,811 studies remained. Finally, 24 studies1134 were selected according to the selection and exclusion criteria (Fig. 1). The study characteristics are presented in Table 1. The findings of the quality assessment of all the included studies, using the QUADAS-II tool, are shown in Fig. 2. The “reference standard” domain showed a relatively low rate of “low risk of bias” as compared to the others.

2. Comparison of diagnostic yield

The diagnostic yield was reported in 19 studies. The data were analyzed according to the target population, including those with suspected or established CD.

In patients with suspected CD, CE was compared to SBFT, EC, CTE, and MRE (Fig. 3). A total four studies11,13,16,32 compared CE and SBFT, but one study32 was excluded in the meta-analysis because of high heterogeneity in the patient selection. The diagnostic yield of CE was statistically higher than that of SBFT (CE, 66.0% vs SBFT, 21.3%; IYw, 0.44; 95% CI, 0.29 to 0.59; I2, 30%). CE was compared with EC in two studies.14,28 CE showed a superior diagnostic yield as compared to EC (CE, 75.7% vs EC, 29.4%; IYw, 0.50; 95% CI, 0.21 to 0.79; I2, 52%). However, CE did not show a superior diagnostic yield as compared to CTE in two studies13,29 (CE, 72.5% vs CTE, 22.5%; IYw, 0.36; 95% CI, 0.18 to 0.90; I2, 68%). Moreover, CE did not show a significant superior diagnostic yield as compared to MRE in two studies (CE, 85.7% vs MRE, 100%; IYw, −0.16; 95% CI, −0.63 to 0.32; I2, 44%).20,27

In patients with established CD, CE only showed a statistically superior diagnostic yield as compared to EC group in four studies (CE, 68.5% vs EC, 36.7%; IYw, 0.39; 95% CI, 0.28 to 0.50; I2, 0%).14,15,17,28 The diagnostic yield of other modalities, such as SBFT, CTE, MRE, and IC, was not significantly different as compared to that of CE (Fig. 4).

3. Diagnostic accuracy

The reference standards varied in the included studies. Therefore, quantitative data was not synthesized for the calculation of diagnostic accuracy, although the sensitivity and specificity were calculated (Table 2).

In patients with suspected CD, two studies reported that the sensitivity and specificity of CE were 62% to 100% and 50% to 100%, whereas those for MRE were 77% and 80%, respectively.14,16 SBFT had the lowest sensitivity (27.6%) and 100% specificity.

In patients with established CD, the sensitivity and specificity of CE was found to be 77% to 100% and 53% to 100% in seven studies, respectively.14,17,19,22,25,31,33 The sensitivity and specificity of CTE were 76% to 82% and 85% to 89%, respectively, in two studies.25,31 Moreover, the sensitivity and specificity of MRE were 77% to 81% and 80% to 90%, respectively, in three studies.14,31,33

4. Detection of the terminal ileum lesion

In the detection of lesions in the terminal ileum in cases of established CD, the use of CE was compared to the use of ileocolonoscopy (IC) or CTE (Fig. 5) in five studies.18,19,22,24,31 The diagnostic yield of CE was statistically higher than that of IC (CE, 60% vs IC, 48%; IYw, 0.11; 95% CI, 0.00 to 0.22; I2, 55%). However, the diagnostic yield of CE was not superior to that of CTE (CE, 40% vs CTE, 32%; IYw, 0.08; 95% CI, −0.02 to 0.19; I2, 84%).

5. Additional diagnostic gain

A total four studies reported the additional lesions detected by CE. CE identified 40% (12/30) more lesions as compared to SBFT and small intestine contrast ultrasonography.32 Moreover, CE identified a mucosal lesion in six patients who showed normal results on SBFT.12 Furthermore, CE showed additional lesions that were not detected on MRE (9/52).26 With regard to the detection of recurrent lesions in the terminal ileum, CE showed two more lesions as compared to IC.19

The satisfaction of patients with CE, as compared to other modalities, has been reported in two studies. Patients preferred CE to MRE or balloon-assisted enteroscopy (2.73 vs 1.43 and 1.85, p<0.001) due to the lower burden of the examination in terms of discomfort during insertion, pain, and difficulty in swallowing.34 Moreover, CE was preferred to IC. Patients experienced greater discomfort during examination preparation and daily activities with IC (80%) than with CE (20%).24

6. Safety-related outcomes

A total of eight studies reported adverse events related to CE (Table 3).12,18,21,23,25,26,32,33 The most common adverse event included capsule retention (5.5%, 14 of 255 patients). Capsule malfunction was reported in one study (one of 28 patients), and abdominal pain was reported in one study. Incomplete examination results were reported in five studies (Table 4).14,15,17,21,28 However, incomplete examination results in CE were only noted in 7.5% patients (12 of 160 patients), as compared to those noted in other modalities (MRE, 12%; IC, 24%; and EC, 10.5%).

DISCUSSION

In the present study, we provided updated information from published relevant systematic reviews, and focused on the additional diagnostic gain with the use of CE in the clinical field. Similar previous meta-analyses focused on a comparison of the diagnostic yield; however, these studies included data from abstracts that were excluded in the present study as they yield inconsistent result.7,8,35 For a more precise comparison of diagnostic yield, we only included published studies, and divided the patients into cases with suspected and established CD. Moreover, a subgroup analysis was performed to identify the effectiveness of the diagnosis of terminal ileum lesions. Furthermore, we attempted to identify the additional diagnostic information or benefits in CD patients, including patient preference or satisfaction as well as adverse events.

Previous studies assumed that there would be different benefits for each patient group, and they indicated different results based on each patient group.7,8,35 In the present study, the diagnostic yield of CE was found to be superior to that of other modalities in several subgroup comparisons, although not all the comparisons showed consistency in effectiveness. In cases of suspected CD, CE showed a higher diagnostic yield as compared to SBFT and EC. As no reference standard has been established, it is difficult to identify lesions in asymptomatic patients; however, an advantage of CE is that it enables the visualization of the entire small bowel, and hence, small bowel lesions can be easily and directly detected.36 Our results may reflect this phenomenon. In contrast, in cases of established CD, CE showed a higher diagnostic yield as compared to EC; this has been also observed in previous studies.7,8 A previous meta-analysis on CE indicated that it had a higher diagnostic yield as compared to CTE in the cases with established disease and not in the cases with suspected disease.8 However, that study included abstracts and studies that were still in press. CD is frequently accompanied by extraluminal inflammation. In such cases, CTE and MRE may serve as more useful diagnostic modalities.37 Thus, our results reflect the strengths and limitations of CE.

In most patients with CD, the lesions are located in the terminal ileum, which can be accessed by IC.36 Previous meta-analyses did not report any comparisons of modalities based on the lesions of this area; however, we performed such a comparison in the subgroup analysis. With regard to the detection of the recurrence of terminal ileum lesions, CE has a more superior diagnostic yield than IC, but a comparable diagnostic yield with CTE. The small bowel beyond the duodenum and proximal to the terminal ileum is inaccessible in conventional endoscopy;36 therefore, CE would be a useful modality to examine terminal ileum lesions.

Although the included studies reported on the diagnostic accuracy, different reference standards have been used, as shown Table 1. SBFT and EC have been regarded as reference standard for radiographic assessment, but CTE and MRE are more accurate for the diagnosis of CD.36 In the present study, we could not determine whether CE had a superior diagnostic performance as compared to MRE or CTE. CD can be accompanied by extraluminal inflammation, and MRE and CTE are relatively novel and enhanced radiographic diagnostic methods that are more accurate for diagnosis as compared to SBFT or EC in such cases.36 Moreover, MRE is particularly useful for detecting transmural inflammation, stenosis, and extraintestinal lesions including abscesses and fistula.26,37 However, diagnostic effectiveness should not be judged based on diagnostic performance alone. The characteristics of CD such as systemic inflammation as well as recurrence are difficult to detect.37 CE shows the entire small bowel through the canal, and has a higher successful completion rate than other endoscopic modalities. One systematic review reported a pooled completion rate of CE of 84.4%, wherein single-arm studies were included.38

Moreover, patient preference and additional diagnostic gain should be considered in the clinical decision. Patient satisfaction was higher in the CE group, in terms of comfort during the procedure, as compared to other diagnostic methods. The most frequent adverse event related to CE was capsule retention. In the present study, the capsule retention rate was 5.4%. One systematic review reported a retention rate of 2.6%, although this review included single-arm studies, and hence included a large number of studies.38 A previous study of a large cohort reported a retention rate of 8.3% in CD.39 Capsule retention primarily occurs in cases of luminal stricture and stenosis.26 Therefore, in cases without stricture or stenosis of the bowel lumen, the use of CE is appropriate, as the retention rate would be acceptable.

This study has certain limitations. As the heterogeneity of the data was high, we performed subgroup analysis according to the patients and modalities. Therefore, the number of studies included in each subgroup analysis was too small to determine whether the effectiveness was significant. Moreover, there were differences in the reference standards and procedure settings, such as the interval of test timing and patient severity; this may also affect heterogeneity. In those studies used in this meta-analysis, as the patients of CD with known strictures which can be present in up to 25% of CD were excluded, the results have shown the yield of CE in a subgroup of patients with nonstricturing CD. If this population was included in the meta-analysis, the diagnostic yield of CTE and MRE would be higher. Other than that, the lack of a reference and/or gold standard may results in a confirmation bias, which may favor CE. CE found small bowel abnormality in about 20% of asymptomatic control patients,40 suggesting that many findings on CE maybe nonspecific and unrelated to the CD.

Our meta-analysis demonstrates that CE is superior to SBFT and EC in the evaluation of suspected CD. CE is also a more effective diagnostic modality in patients with established CD, as compared to EC. Moreover, other modalities such as CTE or MRE showed a similar diagnostic performance compared to CE. However, CE may be an effective diagnostic method to diagnose patients who do not show any abnormality in radiographic screening without the risk of stricture or stenosis. Moreover, CE can be more helpful in identifying terminal ileum lesions as compared to IC. In addition, patients appear to prefer CE over other modalities.

Larger prospective studies are needed to establish the role of CE for diagnosing suspected small bowel CD and evaluating established CD. As it is unknown whether these results will translate into improved patient outcomes or decrease health care expenditures with CE versus other modalities, randomized controlled trials will be necessary to answer these questions.

ACKNOWLEDGEMENTS

This study was funded by the National Evidence-based Healthcare Collaborating Agency (NECA), project number: NECA-C-14-008.

Fig 1.

Figure 1.Flow diagram of the study selection process.

DB, database; CD, Crohn’s disease.

Gut and Liver 2017; 11: 62-72https://doi.org/10.5009/gnl16015

Fig 2.

Figure 2.Quality assessments of the included studies. (A) Risk of bias graph. (B) Applicability concerns graph.
Gut and Liver 2017; 11: 62-72https://doi.org/10.5009/gnl16015

Fig 3.

Figure 3.Comparison of the diagnostic yield of different modalities for suspected Crohn’s disease. (A) Comparison of the diagnostic yields of CE and SBFT. (B) Comparison of the diagnostic yields of CE and EC. (C) Comparison of the diagnostic yields of CE and CTE. (D) Comparison of the diagnostic yields of CE and MRE.

CE, capsule endoscopy; SBFT, small bowel follow-through; IYw, weighted incremental yield; CI, confidence interval; EC, enteroclysis; CTE, computed tomography enterography; MRE, magnetic resonance enterography.

Gut and Liver 2017; 11: 62-72https://doi.org/10.5009/gnl16015

Fig 4.

Figure 4.Comparison of the diagnostic yield of different modalities for established Crohn’s disease. (A) Comparison of the diagnostic yields of CE and SBFT. (B) Comparison of the diagnostic yields of CE and EC. (C) Comparison of the diagnostic yields of CE and CTE. (D) Comparison of the diagnostic yields of CE and MRE. (E) Comparison of the diagnostic yields of CE and IC.

CE, capsule endoscopy; SBFT, small bowel follow-through; IYw, weighted incremental yield; CI, confidence interval; EC, enteroclysis; CTE, computed tomography enterography; MRE, magnetic resonance enterography; IC, ileocolonoscopy.

Gut and Liver 2017; 11: 62-72https://doi.org/10.5009/gnl16015

Fig 5.

Figure 5.Comparison of the diagnostic yield of different modalities for the detection of a terminal ileum lesion. (A) Comparison of the diagnostic yields of CE and IC. (B) Comparison of the diagnostic yields of CE and CTE.

CE, capsule endoscopy; IC, ileocolonoscopy; IYw, weighted incremental yield; CI, confidence interval; CTE, computed tomography enterography.

Gut and Liver 2017; 11: 62-72https://doi.org/10.5009/gnl16015

Table 1 Characteristics of the Included Studies

Author (year)CountryPatients (N)Intervention (N)Comparators (N)Reference standard (N)Reported outcomes
Costamagna et al. (2002)11ItalySuspected small-bowel disease (20)CE (20)SBFT (22)Colonoscopy (20)Diagnostic yield
Buchman et al. (2004)12United StatesSuspected CD recurrence (30)CE (30)SBFT (30)Clinician opinion (30)Diagnostic yield
Correlation
Concordance
Additional diagnostic information
Patient satisfaction
Eliakim et al. (2004)13IsraelSuspected CD (35)CE (30)SBFT (35)IC and clinician opinion (35)Diagnostic yield
CTE (35)
IC (17)Patient satisfaction
Albert et al. (2005)14GermanySuspected and established CD (25)CE (14)MRI (25)All data including IC (52)Diagnostic accuracy
EC (24)
Chong et al. (2005)15AustraliaCrohn’s history (43)CE (43)PE (43)IC and expert consensus (43)Diagnostic yield
EC (43)Therapeutic impact
Dubcenco et al. (2005)16CanadaSuspected CD (39)CE (39)SBFT (39)IC (39)Diagnostic yield
Diagnostic accuracy
Marmo et al. (2005)17ItalyEstablished CD (31)CE (31)EC (31)Comprehensive decision (31)Diagnostic accuracy
Diagnostic yield
Voderholzer et al. (2005)18GermanyEstablished CD (56)CE (41)CTE (41)EGD or IC (56)Diagnostic yield
Therapeutic impact
Bourreille et al. (2006)19FranceOperated CD (32)CE (31)-IC (31)Diagnostic accuracy
Gölder et al. (2006)20GermanySuspected and established CD (17)CE (17)MRE (17)-Diagnostic yield
Hara et al. (2006)21United StatesSuspected and established CD (17)CE (17)CTE (17)IC (41)Diagnostic yield
SBFT (17)
Biancone et al. (2007)22ItalyEstablished and operated CD (22)CE (17)SBFT (22)IC (22)Diagnostic yield
Diagnostic accuracy
Park et al. (2007)23KoreaEstablished CD (52)CE (52)SBFT (52)Clinician opinion (52)Diagnostic yield
Concordance
Pons Beltrán et al. (2007)24SpainAfter operated CD (24)CE (22)IC (24)Clinician opinion (24)Diagnostic Yield
Patient Satisfaction
Therapeutic impact
Solem et al. (2008)25United StatesSuspected and established CD (41)CE (28)CTE (41)Expert consensus (41)Diagnostic accuracy
IC (36)
SBFT (38)
Tillack et al. (2008)26GermanyEstablished CD (19)CE (19)MRE (19)Comprehensive determination (19)Concordance
Additional diagnostic information
Crook et al. (2009)27SwitzerlandSuspected CD (5)CE (5)MRE (5)Clinical, histological, biomedical data comprehensive decision (5)Diagnostic accuracy
Diagnostic yield
Efthymiou et al. (2009)28GreeceSuspected or established CD (55)CE (55)EC (55)Expert consensus (55)Diagnostic yield
Rajesh et al. (2009)29United StatesSuspected CD (17)CE (5)CTE (5)Surgical and pathological gold standard data (17)Diagnostic yield
Böcker et al. (2010)30United StatesSuspected and established CD (21)CE (21)MRI (21)-Diagnostic yield
Jensen et al. (2011)31DenmarkSuspected or established CD (93)CE (87)MRE (89)IC, IC+surgery, surgery (75)Diagnostic accuracy
CTE (90)Diagnostic yield
Petruzziello et al. (2011)32ItalySuspected CD (30)CE (30)SBFT (30)Expert consensus (30)Concordance
SICUS (30)Diagnostic yield
IC (30)Additional diagnostic information
Wiarda et al. (2012)33NetherlandSuspected or established CD (38)CE (38)MRE (38)BAE+expert consensus (38)Diagnostic accuracy
Wiarda et al. (2013)34NetherlandSuspected CD (38)CE (59)MRE (76)-Patient preference
OGIB (38)BAE (76)Patient satisfaction

CE, capsule endoscopy; SBFT, small bowel follow-through; CD, Crohn’s disease; IC, ileocolonoscopy; CTE, computed tomography enterography; MRI, magnetic resonance imaging; MRE, magnetic resonance enterography; PE, push enteroscopy; EC, enteroclysis; EGD, esophagogastroduodenoscopy; SICUS, small intestine contrast ultrasonography; BAE, Balloon-assisted enteroscopy; OGIB, obscure gastrointestinal bleeding.


Table 2 Diagnostic Accuracy

Author (year)Reference standard (N)PopulationSubgroupModalities (N)Sensitivity, %Specificity, %
Suspected CD
 Albert et al. (2005)14All clinical data including IC (52)Suspected CD-CE (25)92.0100.0
MRE (25)77.080.0
 Dubcenco et al. (2005)16IC (39)Suspected CD-CE (39)89.6100.0
SBFT (39)27.6100.0
Established CD
 Albert et al. (2005)14All data including IC (52)Established CD-CE (27)92.0100.0
MRE (27)77.080.0
 Marmo et al. (2005)17Comprehensive decision (31)Established CDEstablished terminal ileumCE (16)87.0-
EC (16)37.0-
 Bourreille et al. (2006)19Ileoscopy (32)Established CDLowerCE (31)62.090.0
Upper76.0100.0
LowerIC (31)86.050.0
Upper86.079.0
 Biancone et al. (2007)22IC (22)Established CDRecurrenceCE (22)100.0100.0
Terminal ileum recurCE (17)93.067.0
 Solem et al. (2008)25Expert consensus (41)Established CDCE (27)83.053.0
CTE (41)82.089.0
 Jensen et al. (2011)31IC, IC+surgery, surgery (75)Established CD-CE (87)100.091.0
MRE (89)81.086.0
CTE (90)76.085.0
 Wiarda et al. (2012)33BAE+expert consensus (38)Established CD-CE (38)57.188.9
MRE (38)76.789.5

CD, Crohn’s disease; IC, ileocolonoscopy; CE, capsule endoscopy; MRE, magnetic resonance enterography; SBFT, small bowel follow-through; EC, enteroclysis; CTE, computed tomography enterography; BAE, balloon-assisted enteroscopy.


Table 3 Capsule-Related Adverse Events

Author (year)Capsule retention, % (n/N)Capsule malfunction, % (n/N)Cause (n)
Buchman et al. (2004)126.7 (2/30)-Small bowel stenosis (2)
Voderholzer et al. (2005)184.9 (2/41)-Terminal ileum inflammation (1), jejunal stenosis (1)
Hara et al. (2006)215.9 (1/17)-Small bowel stenosis (1)
Park et al. (2007)239.6 (5/52)-Small bowel stenosis (5)
Solem et al. (2008)25-3.6 (1/28)Technical failure (1)
Tillack et al. (2008)265.3 (1/19)-Site of stenosis
Petruzziello et al. (2011)323.3 (1/30)-Ulcerated stenosis (1)
Wiarda et al. (2012)332.6 (1/38)-Small bowel stenosis (1)

Table 4 Incomplete Examination Rate and Causes

Author (year)Index testComparators


CE, % (n/N)Cause, % (n)MRE, % (n/N)IC, % (n/N)EC, % (n/N)Cause (n)
Albert et al. (2005)147.1 (1/14)Retention (1)12.0 (3/25)-8.3 (2/24)-
Chong et al. (2005)152.3 (1/43)Dysphagia (1)--13.9 (6/43)Tube insertion failure and denial (6)
Marmo et al. (2005)1725.8 (8/31)Cecum reach failure (2), low quality of result (6)--0 (0/31)-
Hara et al. (2006)2111.7 (2/17)--23.5 (4/17)--
Efthymiou et al. (2009)280 (0/55)---1.5 (8/55)Tube insertion failure (8)

CE, capsule endoscopy; MRE, magnetic resonance enterography; IC, ileocolonoscopy; EC, enteroclysis.


References

  1. Baumgart, DC, and Sandborn, WJ (2012). Crohn’s disease. Lancet. 380, 1590-1605.
    Pubmed CrossRef
  2. Gower-Rousseau, C, Vasseur, F, and Fumery, M (2013). Epidemiology of inflammatory bowel diseases: new insights from a French population-based registry (EPIMAD). Dig Liver Dis. 45, 89-94.
    CrossRef
  3. Nuij, VJ, Zelinkova, Z, and Rijk, MC (2013). Phenotype of inflammatory bowel disease at diagnosis in the Netherlands: a population-based inception cohort study (the Delta Cohort). Inflamm Bowel Dis. 19, 2215-2222.
    Pubmed CrossRef
  4. Sjöberg, D, Holmström, T, and Larsson, M (2014). Incidence and clinical course of Crohn’s disease during the first year-results from the IBD Cohort of the Uppsala Region (ICURE) of Sweden 2005–2009. J Crohns Colitis. 8, 215-222.
    CrossRef
  5. Yang, SK, Yun, S, and Kim, JH (2008). Epidemiology of inflammatory bowel disease in the Songpa-Kangdong district, Seoul, Korea, 1986–2005: a KASID study. Inflamm Bowel Dis. 14, 542-549.
    CrossRef
  6. Abdul-Baki, H, ElHajj, I, and El-Zahabi, LM (2007). Clinical epidemiology of inflammatory bowel disease in Lebanon. Inflamm Bowel Dis. 13, 475-480.
    Pubmed CrossRef
  7. Triester, SL, Leighton, JA, and Leontiadis, GI (2006). A meta-analysis of the yield of capsule endoscopy compared to other diagnostic modalities in patients with non-stricturing small bowel Crohn’s disease. Am J Gastroenterol. 101, 954-964.
    Pubmed CrossRef
  8. Dionisio, PM, Gurudu, SR, and Leighton, JA (2010). Capsule endoscopy has a significantly higher diagnostic yield in patients with suspected and established small-bowel Crohn’s disease: a meta-analysis. Am J Gastroenterol. 105, 1240-1248.
    CrossRef
  9. Whiting, PF, Rutjes, AW, and Westwood, ME (2011). QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 155, 529-536.
    Pubmed CrossRef
  10. Higgins, JP, and Green, S (2008). Cochrane handbook for systematic reviews of interventions. Chichester: Wiley-Blackwell
    CrossRef
  11. Costamagna, G, Shah, SK, and Riccioni, ME (2002). A prospective trial comparing small bowel radiographs and video capsule endoscopy for suspected small bowel disease. Gastroenterology. 123, 999-1005.
    Pubmed CrossRef
  12. Buchman, AL, Miller, FH, Wallin, A, Chowdhry, AA, and Ahn, C (2004). Video-capsule endoscopy versus barium contrast studies for the diagnosis of Crohn’s disease recurrence involving the small intestine. Am J Gastroenterol. 99, 2171-2177.
    Pubmed CrossRef
  13. Eliakim, R, Suissa, A, Yassin, K, Katz, D, and Fischer, D (2004). Wireless capsule video endoscopy compared to barium follow-through and computerised tomography in patients with suspected Crohn’s disease: final report. Dig Liver Dis. 36, 519-522.
    Pubmed CrossRef
  14. Albert, JG, Martiny, F, and Krummenerl, A (2005). Diagnosis of small bowel Crohn’s disease: a prospective comparison of capsule endoscopy with magnetic resonance imaging and fluoroscopic enteroclysis. Gut. 54, 1721-1727.
    Pubmed KoreaMed CrossRef
  15. Chong, AK, Taylor, A, Miller, A, Hennessy, O, Connell, W, and Desmond, P (2005). Capsule endoscopy vs. push enteroscopy and enteroclysis in suspected small-bowel Crohn’s disease. Gastrointest Endosc. 61, 255-261.
    Pubmed CrossRef
  16. Dubcenco, E, Jeejeebhoy, KN, and Petroniene, R (2005). Capsule endoscopy findings in patients with established and suspected small-bowel Crohn’s disease: correlation with radiologic, endoscopic, and histologic findings. Gastrointest Endosc. 62, 538-544.
    Pubmed CrossRef
  17. Marmo, R, Rotondano, G, and Piscopo, R (2005). Capsule endoscopy versus enteroclysis in the detection of small-bowel involvement in Crohn’s disease: a prospective trial. Clin Gastroenterol Hepatol. 3, 772-776.
    Pubmed CrossRef
  18. Voderholzer, WA, Beinhoelzl, J, and Rogalla, P (2005). Small bowel involvement in Crohn’s disease: a prospective comparison of wireless capsule endoscopy and computed tomography enteroclysis. Gut. 54, 369-373.
    Pubmed KoreaMed CrossRef
  19. Bourreille, A, Jarry, M, and D’Halluin, PN (2006). Wireless capsule endoscopy versus ileocolonoscopy for the diagnosis of postoperative recurrence of Crohn’s disease: a prospective study. Gut. 55, 978-983.
    Pubmed KoreaMed CrossRef
  20. Gölder, SK, Schreyer, AG, and Endlicher, E (2006). Comparison of capsule endoscopy and magnetic resonance (MR) enteroclysis in suspected small bowel disease. Int J Colorectal Dis. 21, 97-104.
    CrossRef
  21. Hara, AK, Leighton, JA, and Heigh, RI (2006). Crohn disease of the small bowel: preliminary comparison among CT enterography, capsule endoscopy, small-bowel follow-through, and ileoscopy. Radiology. 238, 128-134.
    CrossRef
  22. Biancone, L, Calabrese, E, and Petruzziello, C (2007). Wireless capsule endoscopy and small intestine contrast ultrasonography in recurrence of Crohn’s disease. Inflamm Bowel Dis. 13, 1256-1265.
    Pubmed CrossRef
  23. Park, CH, Kim, JO, and Choi, MG (2007). Utility of capsule endoscopy for the classification of Crohn’s disease: a multicenter study in Korea. Dig Dis Sci. 52, 1405-1409.
    Pubmed CrossRef
  24. Pons Beltrán, V, Nos, P, and Bastida, G (2007). Evaluation of postsurgical recurrence in Crohn’s disease: a new indication for capsule endoscopy?. Gastrointest Endosc. 66, 533-540.
    CrossRef
  25. Solem, CA, Loftus, EV, and Fletcher, JG (2008). Small-bowel imaging in Crohn’s disease: a prospective, blinded, 4-way comparison trial. Gastrointest Endosc. 68, 255-266.
    Pubmed CrossRef
  26. Tillack, C, Seiderer, J, and Brand, S (2008). Correlation of magnetic resonance enteroclysis (MRE) and wireless capsule endoscopy (CE) in the diagnosis of small bowel lesions in Crohn’s disease. Inflamm Bowel Dis. 14, 1219-1228.
    Pubmed CrossRef
  27. Crook, DW, Knuesel, PR, and Froehlich, JM (2009). Comparison of magnetic resonance enterography and video capsule endoscopy in evaluating small bowel disease. Eur J Gastroenterol Hepatol. 21, 54-65.
    CrossRef
  28. Efthymiou, A, Viazis, N, and Vlachogiannakos, J (2009). Wireless capsule endoscopy versus enteroclysis in the diagnosis of small-bowel Crohn’s disease. Eur J Gastroenterol Hepatol. 21, 866-871.
    Pubmed CrossRef
  29. Rajesh, A, Sandrasegaran, K, and Jennings, SG (2009). Comparison of capsule endoscopy with enteroclysis in the investigation of small bowel disease. Abdom Imaging. 34, 459-466.
    CrossRef
  30. Böcker, U, Dinter, D, and Litterer, C (2010). Comparison of magnetic resonance imaging and video capsule enteroscopy in diagnosing small-bowel pathology: localization-dependent diagnostic yield. Scand J Gastroenterol. 45, 490-500.
    Pubmed CrossRef
  31. Jensen, MD, Nathan, T, Rafaelsen, SR, and Kjeldsen, J (2011). Diagnostic accuracy of capsule endoscopy for small bowel Crohn’s disease is superior to that of MR enterography or CT enterography. Clin Gastroenterol Hepatol. 9, 124-129.
    CrossRef
  32. Petruzziello, C, Calabrese, E, and Onali, S (2011). Small bowel capsule endoscopy vs conventional techniques in patients with symptoms highly compatible with Crohn’s disease. J Crohns Colitis. 5, 139-147.
    Pubmed CrossRef
  33. Wiarda, BM, Mensink, PB, and Heine, DG (2012). Small bowel Crohn’s disease: MR enteroclysis and capsule endoscopy compared to balloon-assisted enteroscopy. Abdom Imaging. 37, 397-403.
    CrossRef
  34. Wiarda, BM, Stolk, M, and Heine, DG (2013). Patient burden and patient preference: comparing magnetic resonance enteroclysis, capsule endoscopy and balloon-assisted enteroscopy. J Gastroenterol Hepatol. 28, 464-471.
    CrossRef
  35. Park, SK, Ye, BD, and Kim, KO (2015). Guidelines for video capsule endoscopy: emphasis on Crohn’s disease. Clin Endosc. 48, 128-135.
    Pubmed KoreaMed CrossRef
  36. Bourreille, A, Ignjatovic, A, and Aabakken, L (2009). Role of small-bowel endoscopy in the management of patients with inflammatory bowel disease: an international OMED-ECCO consensus. Endoscopy. 41, 618-637.
    Pubmed CrossRef
  37. Naganuma, M, Hosoe, N, Kanai, T, and Ogata, H (2015). Recent trends in diagnostic techniques for inflammatory bowel disease. Korean J Intern Med. 30, 271-278.
    Pubmed KoreaMed CrossRef
  38. Liao, Z, Gao, R, Xu, C, and Li, ZS (2010). Indications and detection, completion, and retention rates of small-bowel capsule endoscopy: a systematic review. Gastrointest Endosc. 71, 280-286.
    Pubmed CrossRef
  39. Cheon, JH, Kim, YS, and Lee, IS (2007). Can we predict spontaneous capsule passage after retention? A nationwide study to evaluate the incidence and clinical outcomes of capsule retention. Endoscopy. 39, 1046-1052.
    Pubmed CrossRef
  40. Goldstein, JL, Eisen, GM, and Lewis, B (2005). Video capsule endoscopy to prospectively assess small bowel injury with celecoxib, naproxen plus omeprazole, and placebo. Clin Gastroenterol Hepatol. 3, 133-141.
    Pubmed CrossRef
Gut and Liver

Vol.18 No.5
September, 2024

pISSN 1976-2283
eISSN 2005-1212

qrcode
qrcode

Share this article on :

  • line

Popular Keywords

Gut and LiverQR code Download
qr-code

Editorial Office